Records from 2003 to 2024. Most recent: inspection, 23 August 2024.
Inspection history · 35
23 August 2024
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7987424
25 March 2022
PSC B · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7418662
24 March 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7418096
11 December 2020
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7110365
25 July 2020
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7015579
21 July 2020
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7012350
10 July 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7002755
20 February 2020
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6912396
15 February 2020
Ballast Water Examination · COC-CHEM & TVE Annual · PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6906931
22 April 2019
ISPS II Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6666565
22 April 2019
Bulk Liquid Transfer Monitor
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6667382
28 December 2018
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6603087
26 November 2018
COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6586404
4 June 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6165072
19 May 2017
COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6145387
22 April 2016
Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5860404
12 January 2016
COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5795680
29 April 2009
ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3463754
2 April 2007
MARPOL Annex II Examination · Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · COC-CHEM Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2899210
21 February 2006
Ballast Water Examination · ISPS II Exam · COC-CHEM Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2589214
18 September 2005
ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2495330
2 March 2005
COC-CHEM Renew
Type not classified · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2302392
8 February 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2289019
15 September 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2197173
24 August 2004
ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2174815
4 April 2004
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2037005
28 October 2003
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1937883
13 July 2003
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1844496
4 July 2003
Damage Survey
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1835172
4 July 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1870513
29 June 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1829523
29 June 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1829584
20 March 2003
Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1760195
27 February 2003
Security Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1766905
26 February 2003
Certificate of Compliance
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1749217
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 26 November 2018
Resolved
01 07102 74 SOLAS (01) II-2/62 resolution a.567(14) 50ac The requirements for inert gas systems contained in the Fire Safety Code need not be applied to Chemical Tankers ... developed by the organization ... suitable means shall be provided for the zero and span calibration of both fixed and portable gas concentration measurement instruments. PSCO found nitrogen generator was unable to be checked for calibration with span gas on board to verify oxygen % produced. Annex I cargo with a flash point below 60deg C not to be carried until deficiency is rectified.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 December 2018
Resolution: System serviced & repaired by third party and tested & witnessed by class. Vessel is allowed to carry all Annex I & II cargoes as per endorsed carriage documents IOPP & Cert of Fitness. 02 oxygen sensors replaced, reviewed tech reports, class reports.
Documentation › Certificates/Documents › IOPP Certificate
Issued 19 May 2017
Resolved
0150-IOPP- The IOPP shall be drawn up in the form corresponding to the model given in appendix II to the Annex. IOPP indicated that the OWS monitor was a MEPC 60. MEPC 107 was installed. MARPOL 73 ANNEX I/9. 50a
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 4 June 2017
Resolution: PSC NOLA received a class report from dnv-glsatisfying the requirement.
Lifesaving › Lifeboat › Carriage Requirement
Issued 12 January 2016
Resolved
Freefall lifeboat was lost at sea prior to entry and thus absent during exam. Flag and Class dispensation granted until 24FEB2016.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 February 2016
Resolved 22 April 2016
Resolution: RCVD class report attesting to replacement of free fall lifeboat.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 4 July 2003
Resolved
main propulsion engine has an ovespeed condition, which causes an loss of propulsion. repair engine to prevent risk of overspeed condition again to the satisfaction of the issuing authority of the safety construction cert. LEGACY COMPONENT DESC: Governor
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2003
Resolved 12 July 2003
Resolution: Provided class report attesting to proper repair and testing of the main engine.
Engineering › Steering Gear System
Issued 4 July 2003
Resolved
steering gear is not adequate for controlling the vsl direction. repair steering gear sysytem to the satisfaction of the issuing authority of the safety construction cert. LEGACY COMPONENT DESC: Feedback Unit
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2003
Resolved 12 July 2003
Resolution: Provided class survey report attesting to the satisfactory repair and at sea testing of steering system.
Construction/Loadline › Hull
Issued 4 July 2003
Resolved
Bulbous bow portside shell plating between the sterm and frame 109 an between drafts 6.70m and 8.80m is indented 0-50cm and torn open afffecting an area extending 2.50m H below longitudinal web stiffener. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2003
Resolved 12 July 2003
Resolution: Provided class report attesting to completion, inspection of and at sea testing of permanent repairs to hull.
Lifesaving › Embarkation Appliances/Stations
Issued 26 February 2003
Resolved
Emergency egress routes to lifeboat and liferaft need to be marked in accordance with IMO resolution. LEGACY COMPONENT DESC: Designated Location
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 27 March 2003
Resolved 28 October 2003
Resolution: Shipo had egress routes marked.