STOLT SEQUOIA is a 2003 tank ship. The Coast Guard has recorded 35 inspections since 2003, most recently in August 2024, along with 7 deficiencies and 5 operational controls.

Records from 2003 to 2024. Most recent: inspection, 23 August 2024.

Built
2003
Last inspected
23 August 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9235062 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
610001
Flag
LIBERIA
—
Maury page id
psix-610001

Inspections, by type

…with no type recorded7
Years with a record 13 calendar years (2003–2024)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it23129 - Convention (Subpart B), Gross Ton
11931 - Convention (Subpart B), Net Ton
37620 - Dead Weight, Metric Ton
48497 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

KIRBY 7304 Tank Barge · MISLE 52217 · 4 July 2003 · activity 1870513TAYLOR MARIE Towing Vessel · MISLE 132293 · 4 July 2003 · activity 1870513KIRBY 10504 Tank Barge · MISLE 346739 · 4 July 2003 · activity 1870513KIRBY 11507 Tank Barge · MISLE 368965 · 4 July 2003 · activity 1870513KIRBY 15805 Tank Barge · MISLE 421971 · 4 July 2003 · activity 1870513

Inspection history · 35

23 August 2024 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7987424
25 March 2022 PSC B · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7418662
24 March 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7418096
11 December 2020 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7110365
25 July 2020 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7015579
21 July 2020 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7012350
10 July 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7002755
20 February 2020 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6912396
15 February 2020 Ballast Water Examination · COC-CHEM & TVE Annual · PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6906931
22 April 2019 ISPS II Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6666565
22 April 2019 Bulk Liquid Transfer Monitor
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6667382
28 December 2018 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6603087
26 November 2018 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6586404
4 June 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6165072
19 May 2017 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6145387
22 April 2016 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5860404
12 January 2016 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5795680
29 April 2009 ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3463754
2 April 2007 MARPOL Annex II Examination · Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · COC-CHEM Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2899210
21 February 2006 Ballast Water Examination · ISPS II Exam · COC-CHEM Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2589214
18 September 2005 ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2495330
2 March 2005 COC-CHEM Renew
Type not classified · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2302392
8 February 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2289019
15 September 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2197173
24 August 2004 ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2174815
4 April 2004 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2037005
28 October 2003 Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1937883
13 July 2003 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1844496
4 July 2003 Damage Survey
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1835172
4 July 2003 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1870513
29 June 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1829523
29 June 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1829584
20 March 2003 Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1760195
27 February 2003 Security Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1766905
26 February 2003 Certificate of Compliance
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1749217

Deficiency record · 7

07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 26 November 2018 Resolved
01 07102 74 SOLAS (01) II-2/62 resolution a.567(14) 50ac The requirements for inert gas systems contained in the Fire Safety Code need not be applied to Chemical Tankers ... developed by the organization ... suitable means shall be provided for the zero and span calibration of both fixed and portable gas concentration measurement instruments. PSCO found nitrogen generator was unable to be checked for calibration with span gas on board to verify oxygen % produced. Annex I cargo with a flash point below 60deg C not to be carried until deficiency is rectified.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 December 2018
Resolution: System serviced & repaired by third party and tested & witnessed by class. Vessel is allowed to carry all Annex I & II cargoes as per endorsed carriage documents IOPP & Cert of Fitness. 02 oxygen sensors replaced, reviewed tech reports, class reports.
Documentation › Certificates/Documents › IOPP Certificate
Issued 19 May 2017 Resolved
0150-IOPP- The IOPP shall be drawn up in the form corresponding to the model given in appendix II to the Annex. IOPP indicated that the OWS monitor was a MEPC 60. MEPC 107 was installed. MARPOL 73 ANNEX I/9. 50a
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 4 June 2017
Resolution: PSC NOLA received a class report from dnv-glsatisfying the requirement.
Lifesaving › Lifeboat › Carriage Requirement
Issued 12 January 2016 Resolved
Freefall lifeboat was lost at sea prior to entry and thus absent during exam. Flag and Class dispensation granted until 24FEB2016.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 February 2016
Resolved 22 April 2016
Resolution: RCVD class report attesting to replacement of free fall lifeboat.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 4 July 2003 Resolved
main propulsion engine has an ovespeed condition, which causes an loss of propulsion. repair engine to prevent risk of overspeed condition again to the satisfaction of the issuing authority of the safety construction cert. LEGACY COMPONENT DESC: Governor
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2003
Resolved 12 July 2003
Resolution: Provided class report attesting to proper repair and testing of the main engine.
Engineering › Steering Gear System
Issued 4 July 2003 Resolved
steering gear is not adequate for controlling the vsl direction. repair steering gear sysytem to the satisfaction of the issuing authority of the safety construction cert. LEGACY COMPONENT DESC: Feedback Unit
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2003
Resolved 12 July 2003
Resolution: Provided class survey report attesting to the satisfactory repair and at sea testing of steering system.
Construction/Loadline › Hull
Issued 4 July 2003 Resolved
Bulbous bow portside shell plating between the sterm and frame 109 an between drafts 6.70m and 8.80m is indented 0-50cm and torn open afffecting an area extending 2.50m H below longitudinal web stiffener. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2003
Resolved 12 July 2003
Resolution: Provided class report attesting to completion, inspection of and at sea testing of permanent repairs to hull.
Lifesaving › Embarkation Appliances/Stations
Issued 26 February 2003 Resolved
Emergency egress routes to lifeboat and liferaft need to be marked in accordance with IMO resolution. LEGACY COMPONENT DESC: Designated Location
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 27 March 2003
Resolved 28 October 2003
Resolution: Shipo had egress routes marked.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.