MAURY USCG vessel records Sign in
← All vessels

SILVER LINING

SILVER LINING is a 2003 tank ship. The Coast Guard has recorded 18 inspections since 2003, most recently in May 2014, along with 8 deficiencies and 6 operational controls.

Records from 2003 to 2014. Most recent: inspection, 15 May 2014.

Built
2003
Last inspected
15 May 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9266475 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
611064
Flag
PANAMA
—
Maury page id
psix-611064

Inspections, by type

…with no type recorded7
Years with a record 8 calendar years (2003–2014)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11645 - Convention (Subpart B), Net Ton
46013 - Dead Weight, Ton
54786 - Displacement, Ton
28059 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SONNY COOK Towing Vessel · MISLE 112495 · 2 June 2012 · activity 4333437MARY PARKER Towing Vessel · MISLE 134191 · 2 June 2012 · activity 4333437RT MALBEC Freight Ship · MISLE 228257 · 2 June 2012 · activity 4333437

Inspection history · 18

15 May 2014 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4859063
12 May 2014 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4857100
2 June 2012 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4333437
23 May 2012 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4319685
18 May 2012 In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4315108
30 December 2011 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4216001
23 December 2011 ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4213046
24 August 2008 ISPS II Exam · Deficiency Check · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3304749
25 March 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3170757
25 March 2008 Ballast Water Examination · COC-TVE Annual · MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3170822
10 May 2007 Deficiency Check · Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2927124
25 March 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2894445
7 July 2006 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2703897
7 July 2006 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2703903
17 June 2004 MTSA/ISPS Verification · Tank Vessel Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2099386
10 December 2003 Type not recorded
No type recorded · USCGC KISKA (WPB 1336) · USCG Oceania District (CGD-O) · Activity 1994514
12 March 2003 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1755275
12 March 2003 Type not recorded
No type recorded · USCGC KITTIWAKE (WPB 87316) · USCG Oceania District (CGD-O) · Activity 1762268

Deficiency record · 8

Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Discharge Hose
Issued 23 December 2011 Resolved
0720 - Fire fighting equipment - Fire-extinguishing appliances shall be kept in good order and be available for immediate use at all times. Hose of 45L chemical foam portable extinguisher in the engine room is damaged where it connects to the cylinder. Rectify to satisfaction of the Coast Guard prior to departure. SOLAS 2001 Cond. Ch. II-2/21
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 December 2011
Resolution: Recieved Class report attesting to the replacement of the 50L AFFF semi-portable fire extinguisher
Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 24 August 2008 Resolved
1100-Cargo-The Scrubber in the IGS is holed and patched in the area of the IG inlet cooling nozzles. Class to approve and verify repairs.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 August 2008
Resolved 5 September 2008
Resolution: Cleared item based on receipt of NKK Class Report #08LA0103, dated 30 Aug 2008.
Engineering › Sea-water System (primary cooling) › Piping
Issued 24 August 2008 Resolved
1400-Propulsion and Aux. Machinery-Temporary soft patches were found in the engine room without reports made to the company. a) Inlet pipe for air conditioning CSW pump. b) Marine Growth Protection System (MGPS) cross connect pipe. Class to approve and verify repairs.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 August 2008
Resolved 5 September 2008
Resolution: Cleared item based on receipt of NKK Class Report #08LA0103, dated 30 Aug 2008.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 24 August 2008 Resolved
1100-Cargo-Cargo Vapor Collection connections missing pins at the STBD Manifold FWD and Aft flanges. Class to verify connections.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 August 2008
Resolved 5 September 2008
Resolution: Cleared item based on receipt of NKK Class Report #08LA0103, dated 30 Aug 2008.
Navigation › Piloting/Steering › Gyro Compass
Issued 7 July 2006 Resolved
Gyro compass was inoperable upon arrival. Letter of Deviation was issued.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2006
Resolution: Received fax report of corrections made to Gyro Compass.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 7 July 2006 Resolved
Cargo pumproom not certified Gas Free.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 July 2006
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 15 June 2004 Resolved
Vsl's cargo tank levels exceeded (tanks 2 P&S, 3 P&S, 4P&S, 5P&S, 6P&S, 7P&S) overfill setting of 98%. Test all overfill alarms in actual overfill (high, high) condition.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2004
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 15 June 2004 Resolved
Vessel failed to notify CG COTP of a Hazardous condition (cargo tanks overfill alarms activiated). Provide a Letter of Undertaking in the amount of $65,000.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2004

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.