Records from 2003 to 2014. Most recent: inspection, 15 May 2014.
Inspection history · 18
15 May 2014
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4859063
12 May 2014
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4857100
2 June 2012
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4333437
23 May 2012
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4319685
18 May 2012
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4315108
30 December 2011
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4216001
23 December 2011
ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4213046
24 August 2008
ISPS II Exam · Deficiency Check · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3304749
25 March 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3170757
25 March 2008
Ballast Water Examination · COC-TVE Annual · MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3170822
10 May 2007
Deficiency Check · Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2927124
25 March 2007
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2894445
7 July 2006
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2703897
7 July 2006
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2703903
17 June 2004
MTSA/ISPS Verification · Tank Vessel Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2099386
10 December 2003
Type not recorded
No type recorded · USCGC KISKA (WPB 1336) · USCG Oceania District (CGD-O) · Activity 1994514
12 March 2003
Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1755275
12 March 2003
Type not recorded
No type recorded · USCGC KITTIWAKE (WPB 87316) · USCG Oceania District (CGD-O) · Activity 1762268
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Discharge Hose
Issued 23 December 2011
Resolved
0720 - Fire fighting equipment - Fire-extinguishing appliances shall be kept in good order and be available for immediate use at all times. Hose of 45L chemical foam portable extinguisher in the engine room is damaged where it connects to the cylinder. Rectify to satisfaction of the Coast Guard prior to departure. SOLAS 2001 Cond. Ch. II-2/21
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 December 2011
Resolution: Recieved Class report attesting to the replacement of the 50L AFFF semi-portable fire extinguisher
Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 24 August 2008
Resolved
1100-Cargo-The Scrubber in the IGS is holed and patched in the area of the IG inlet cooling nozzles. Class to approve and verify repairs.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 August 2008
Resolved 5 September 2008
Resolution: Cleared item based on receipt of NKK Class Report #08LA0103, dated 30 Aug 2008.
Engineering › Sea-water System (primary cooling) › Piping
Issued 24 August 2008
Resolved
1400-Propulsion and Aux. Machinery-Temporary soft patches were found in the engine room without reports made to the company. a) Inlet pipe for air conditioning CSW pump. b) Marine Growth Protection System (MGPS) cross connect pipe. Class to approve and verify repairs.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 August 2008
Resolved 5 September 2008
Resolution: Cleared item based on receipt of NKK Class Report #08LA0103, dated 30 Aug 2008.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 24 August 2008
Resolved
1100-Cargo-Cargo Vapor Collection connections missing pins at the STBD Manifold FWD and Aft flanges. Class to verify connections.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 August 2008
Resolved 5 September 2008
Resolution: Cleared item based on receipt of NKK Class Report #08LA0103, dated 30 Aug 2008.
Navigation › Piloting/Steering › Gyro Compass
Issued 7 July 2006
Resolved
Gyro compass was inoperable upon arrival. Letter of Deviation was issued.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2006
Resolution: Received fax report of corrections made to Gyro Compass.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 7 July 2006
Resolved
Cargo pumproom not certified Gas Free.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 July 2006
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 15 June 2004
Resolved
Vsl's cargo tank levels exceeded (tanks 2 P&S, 3 P&S, 4P&S, 5P&S, 6P&S, 7P&S) overfill setting of 98%. Test all overfill alarms in actual overfill (high, high) condition.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2004
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 15 June 2004
Resolved
Vessel failed to notify CG COTP of a Hazardous condition (cargo tanks overfill alarms activiated). Provide a Letter of Undertaking in the amount of $65,000.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2004