Records in 2018. Most recent: operational control imposed, 11 April 2018.
Fire Fighting › Fixed Deck Foam System › Piping
Issued 11 April 2018
Resolved
THE CONDITION OF THE SHIP AND IT'S EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. DUE TO SUBSTANTIAL DETERIORATION ALONG THE FIRE FOAM SUPPLY LINE ON THE CARGO DECK, MULTIPLE FAILURES WERE OBSERVED. AND ALSO MULTIPLE LEAKING FIRE MONITORS WERE OBSERVED.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2018
Resolved 29 April 2018
Resolution: Received class report showing permanent repairs.
Lifesaving › Lifeboat › Propulsion Engine
Issued 11 April 2018
Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE-SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. DURING TESTING OF THE STARBOARD LIFE/RESCUE BOAT THE ENGINE MALFUNCTIONED. WHEN THE ENGINE WAS ENGAGED TO FORWARD, THE RPM'S WENT UP AT A HIGH RATE. THE CREW WAS UNABLE TO SHUT DOWN THE ENGINE FOR BETWEEN ONE AND TWO MINUTES UNTIL THE FUEL SHUT-OFF WAS ACTIVATED. OIL WAS EXPELLED OUT OF THE EXHAUST ON TO THE DECK OF THE SHIP AND INTO THE WATER. 74SOLAS(2014) CH.III/REG. 20.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 11 April 2018
Resolved 15 April 2018
Lifesaving › Lifeboat › Propulsion Engine
Issued 11 April 2018
Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE-SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. AFTER TESTING OF PORT SIDE LIFE BOAT, PSCO OBSERVED EXCESSIVE COLLECTION OF FUEL OIL IN THE LIFE BOAT'S BILGE. 74 SOLAS(2014) CH. III/REG 20.2 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 April 2018
Resolved 13 April 2018
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 11 April 2018
Resolved
THE PURPOSE OF THIS CHAPTER IS FOR THE MINIMIZATION OF POSSIBILITY OF IGNITION OF FLAMMABLE CARGO VAPOR. [name withheld] SOUND AND DETECTED STRONG ODOR COMING FROM CARGO TANK 7 STARBOARD ACCESS HATCH COVER. DISCOVERED GASKET LEAKING GASOLINE FUMES. CREW REPLACED WASTED BOLT ON HATCH COVER BEFORE PSCO'S DEPARTURE FROM VESSEL. 74 SOLAS(2001) CH. II-2/REG. 2.2.8 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 11 April 2018
Resolution: CREW REPLACED WASTED BOLT ON HATCH COVER BEFORE PSCO'S DEPARTURE FROM VESSEL.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 11 April 2018
Resolved
THE PURPOSE OF THIS CHAPTER IS FOR THE CONTAINMENT AND EXTINCTION OF ANY FIRE IN THE SPACE OF ORIGIN. FIRE DAMPER LOCATED IN THE SHIP'S GALLEY WAS NOT ABLE TO BE FULLY CLOSED. 74 SOLAS(2001) CH. II-2/REG. 2.2.5 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2018
Resolved 13 April 2018
Lifesaving › Lifeboat › Markings
Issued 11 April 2018
Resolved
LIFESAVING APLLIANCES SHALL BE FITTED WITH RETRO-REFLECTIVE MATERIAL WHERE IT WILL ASSIST IN DETECTION AND IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE ORGANIZATION. RETRO-REFLECTIVE MATERIAL ON THE PORT AND STARBOARD LIFEBOATS EXTERIOR ARE DETERIORATED. 74 SOLAS(2014) CH. III/REG. 34,LSA CODE I/1.2.2.7 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 April 2018
Resolved 13 April 2018