Inspection history · 64
9 April 2026
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8345276
6 May 2024
MARPOL Annex I Examination · MARPOL Annex VI Survey · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7901636
9 May 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7683990
6 August 2020
Administrative Inspection · In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7035593
9 September 2019
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6844100
15 March 2019
Administrative Inspection · Damage Survey · Examination of Repairs
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6643346
15 March 2019
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6645595
20 February 2019
Internal Structural Exam · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6632705
4 June 2018
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6457879
9 April 2018
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6388065
24 April 2017
Administrative Inspection · Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6153369
7 April 2017
COI Inspection · MARPOL Annex VI Survey · MTSA Verification · Cargo Tank Internal · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6124535
16 February 2017
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6084756
14 August 2016
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5973801
20 July 2016
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5947573
12 April 2016
MTSA/ISPS Verification · Annual Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5852898
27 March 2015
MARPOL Annex VI Survey · MTSA/ISPS Verification · Periodic Inspection · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5089988
16 November 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5036354
3 October 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4998421
3 October 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4998487
29 September 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4994861
12 September 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4987415
12 September 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4995150
7 September 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4989548
5 September 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4987483
3 September 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4973843
2 July 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4908837
21 May 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4885119
31 March 2014
MTSA/ISPS Verification · Internal Structural Exam · MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4824789
30 March 2012
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4274132
17 February 2012
Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4248851
23 December 2011
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4213269
11 February 2010
Deficiency Check · MARPOL Annex I Examination · MTSA Verification · Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3679122
14 May 2009
Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3474130
5 March 2009
Damage Survey · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3428386
9 February 2009
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3422802
13 September 2008
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3542864
14 February 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3148323
30 May 2007
Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2946297
4 January 2007
COI Inspection · MARPOL Annex I Examination · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2849459
4 November 2006
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2817972
28 September 2006
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2789097
6 September 2006
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2770645
28 February 2006
Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2593215
25 October 2005
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2521587
25 October 2005
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2521646
13 December 2004
MTSA Verification · Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2258121
1 July 2004
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2123560
14 May 2004
Hull Examination · Cargo Tank Internal · Internal Structural Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2067910
14 May 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2087193
5 December 2003
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1959036
19 March 2003
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1759550
21 February 2003
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1771157
5 February 2003
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1740204
17 January 2003
Hull Examination · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1732076
9 January 2002
COI Inspection · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1479751
25 August 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 540857
26 July 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 503920
5 May 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 39593
13 April 2001
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1061580
7 February 2001
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 487298
19 January 2001
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1429468
14 January 2000
Hull Examination · Initial Certification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1045444
16 December 1999
Construction Oversight
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1369426
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 12 April 2017
Resolved
Provide service report of annual deck cargo piping hydrostatic testing report.
Action required: 703 - Prior to bunkering operations
Resolved 14 April 2017
Resolution: Cargo deck piping hydrostatically tested and certificate of testing provided.
Electrical › Electric Supply System (service) › Battery Installation
Issued 12 April 2017
Resolved
Remove and replace #2 cargo pump prime mover starter battery, due to damage to terminal lug.
Action required: 703 - Prior to bunkering operations
Resolved 14 April 2017
Resolution: New battery installed.
Documentation › Markings/Placards › Warning Signs
Issued 12 April 2017
Resolved
Install all required warning signs, labels and valve indicators that were removed for paint.
Action required: 703 - Prior to bunkering operations
Resolved 17 April 2017
Resolution: All stencils, warning signs, labels and valve indicators have been installed.
Documentation › Markings/Placards › Warning Signs
Issued 12 April 2017
Resolved
Paint and label fuel shutoff valve for cargo pump prime movers.
Action required: 703 - Prior to bunkering operations
Resolved 17 April 2017
Resolution: Fuel shutoff valve was painted and stenciled.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 12 April 2017
Resolved
Install 03 cargo pump gauges and provide calibration certificates.
Action required: 703 - Prior to bunkering operations
Resolved 19 April 2017
Resolution: Calibration certificates were provided and gauges installed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Gaskets
Issued 12 April 2016
Resolved
Provide gastight gasket in way of cargo pump shaft bulkhead penetration to machinery space for all 3 cargo pumps.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2016
Resolved 15 April 2016
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Gaskets
Issued 12 April 2016
Resolved
Repair gasket in was of cargo pump shaft bulkhead penetration to machinery space for center cargo pump to the satisfaction of the attending marine inspector prior to discharging cargo.
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 30 April 2016
Resolution: Marine inspectors in Valdez, AK attended vessel and examined the new gaskets. Gaskets were satisfactory.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 14 April 2014
Resolved
Panel listing of empty slot is assigned to battery charger. Amperage of circuit breaker for each circuit not listed. Corrected on the spot.
Due 14 April 2014
Resolved 14 April 2014
Resolution: Corrected on the spot.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 2 April 2014
Resolved
Crop out and renew to the good metal #25 vertical swash frame in way of #4 stbd void. Gouged and reweld to 100 percent penetration as original all found weld failure in way of connection of vertical swash frames to side of cargo tanks between 8 & 9 longitudinal that span the length of #3 and #4 stbd void (except for the watertight bulkhead).
Action required: 705 - Other - as specified
Due 4 May 2014
Resolved 11 April 2014
Resolution: Received ABS report from Surveyor [name withheld] attesting sound weld insert of 3/8" steel plate in #25 swash frame.
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 30 March 2012
Resolved
Vessel must provide Coast Guard proof of EIAPP for John Deere Engine S/N RG6081H301525. Vessel must lock out/tag out machinery and must not be used for cargo operations until a valid IAPP has been issued.
Action required: 705 - Other - as specified
Due 18 June 2012
Resolved 13 June 2012
Resolution: EIAPP documentation has been received and IAPP has been issued. All sat
Construction/Loadline › Hull › Transverse Frame
Issued 14 May 2009
Resolved
Port Bow Rake: noticed several frames were cracked in the outboard radius of the cuts to allow frames to be set over bottom longs (longitudinals counted from CVBK).
a. 4" crack; frame (fr) 2 & bottom long (bl) 1
b. 2" crack; fr 2 & bl 10
c. 1" crack; fr 3 & bl 10
d. 2" crack; fr 2 & bl 11
e. 1" crack: fr 2 & bl 14
Repair IAW class rules and/or CG guidance.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 December 2009
Resolved 11 February 2010
Resolution: Attended by ABS and was issued LL Cert.
Construction/Loadline › Hull › Transverse Frame
Issued 14 May 2009
Resolved
#2 stbd: one 18"x18" portion of the side shell vertical web was tripped @ fr 11 & deck knuckle.
Repair IAW class rules and/or CG guidance.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 December 2009
Resolved 11 February 2010
Resolution: Attended by ABS and issued LL.
Construction/Loadline › Hull › Weld
Issued 14 May 2009
Resolved
#2 stbd: 2' from frame 16 on btm side of tank long #4, missing 3"- 4" of weld.
Repair IAW class rules and/or CG guidance.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 December 2009
Resolved 11 February 2010
Resolution: Attended by ABS and issued LL.
Stability › Watertight Integrity › General
Issued 5 March 2009
Resolved
Side shell punctured while hooking the barge up to the tug during rough weather.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 March 2009
Resolved 5 March 2009
Resolution: 30"x30"x1/2" insert on the side shell and 54"x21"x3/8" on the #9 frame squash bulkhead.
Construction/Loadline › Hull › Longitudinal Frame
Issued 30 May 2007
Resolved
Damage to frames and longitudinals described in narrative (35 Action items)
Condition: Damaged By Earlier Event
Due 23 June 2007
Resolved 30 May 2007
Deck/Cargo › Vapor Control Systems › Vapor Recovery Unit
Issued 28 February 2006
Resolved
Install flange stud on port vapor recovery line. Corrected on the spot 2/28/06.
Due 28 February 2006
Resolved 28 February 2006
Lifesaving › Lifebuoys
Issued 17 January 2003
Resolved
Install retroreflective tape on life ring buoy as required by 46 CFR 199.
Action required: 705 - Other - as specified
Due 17 February 2003
Resolved 28 January 2003
Deck/Cargo
Issued 17 January 2003
Resolved
Post emergency shutdown placards as required by 33 CFR 155.780 & 46 CFR 32.50-35.
Action required: 705 - Other - as specified
Due 17 February 2003
Resolved 28 January 2003
Electrical › Electric Supply System (service)
Issued 17 January 2003
Resolved
Renew AC electrical system cycle meter for barge's service generator.
Action required: 705 - Other - as specified
Due 17 February 2003
Resolved 20 January 2003
Engineering › Compressed Air System (control)
Issued 17 January 2003
Resolved
Remove non Coast Guard approved air receiver from machinery space or submit plans for the installation of compressed air receiver.
Action required: 705 - Other - as specified
Due 17 February 2003
Resolved 5 February 2003
Deck/Cargo
Issued 17 January 2003
Resolved
Conduct test of the vessel's cargo high level alarms in the pressence of an attending Marine Inspector.
Action required: 705 - Other - as specified
Due 17 February 2003
Resolved 21 February 2003
Resolution: Attended vsl and witnessed sat tests of the cargo system high level alarms using new portable briefcase-style alarm console.
Electrical › Lighting (service)
Issued 17 January 2003
Resolved
Repair as new lighting fixture above the port and starboard machinery space entry. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 17 February 2003
Resolved 20 January 2003
Electrical › Electrical Distribution System (service) › Cable
Issued 17 January 2003
Resolved
Repair as new electrical connection in way of bow winch hydraulics motor.
Due 17 January 2003
Resolved 17 January 2003
Electrical › Electrical Distribution System (service)
Issued 17 January 2002
Resolved
Provide a blank for the #14 and #15 positions on the "LP" electrical panel. LEGACY COMPONENT DESC: Panelboard
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 January 2002
Resolved 1 February 2002
Deck/Cargo › Holds/Tanks
Issued 17 January 2002
Resolved
Repair the broken cargo tank hatch dogs on the #1S, #2P, and #4P tanks. LEGACY COMPONENT DESC: Hatch Cover
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 January 2002
Resolved 1 February 2002
Resolution: New hatch dogs installed.
Engineering › Fuel Oil Storage/Transfer System
Issued 9 January 2002
Resolved
Remove plastic sight glass and fittings from the machinery fuel tank. If a sight glass fuel level gauge is desired, it must be as per 46 CFR subchapter F and applicable ABS standards. LEGACY COMPONENT DESC: Gauge
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 January 2002
Resolved 1 February 2002
Resolution: The sight glass was removed and the holes in the tank were plugged.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 9 January 2002
Resolved
Demonstate operation of cargo pump relief valves. LEGACY COMPONENT DESC: Relief Valve
Action required: 705 - Other - as specified
Due 30 January 2002
Resolved 1 February 2002
Resolution: Witnessed crew test and reset cargo pump relief valves to 145psi.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 9 January 2002
Resolved
Show proof that the cargo discharge pressure gauges have been checked for accuracy in the last year.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2002
Resolved 1 February 2002
Deck/Cargo › Holds/Tanks
Issued 9 January 2002
Resolved
Repair the cargo tank hatch gasket on the #1P tank. LEGACY COMPONENT DESC: Hatch Cover
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 January 2002
Resolved 1 February 2002
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 9 January 2002
Resolved
Provide 1 additional BII fire extinguisher.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 January 2002
Resolved 1 February 2002
Electrical › Electrical Distribution System (service)
Issued 9 January 2002
Resolved
Submit a single line electrical diagram for approval of the new air compressor instalation. The compressor may not be operated until the drawing and installation is approved.
Action required: 705 - Other - as specified
Due 30 January 2002
Resolved 1 February 2002
Resolution: The compressor electrical system was removed.
Documentation
Issued 19 January 2001
Resolved
Update vessel respone plan Appendix for vessel specific information in accordance with 33 CFR 155.1030(c)(11).
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Deck/Cargo
Issued 19 January 2001
Resolved
Cargo operations involving use of vapor recovery system are not authorized until pin is installed in accordance with 46 CFR 39.20-1(e).
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001