MAURY USCG vessel records Sign in
← All vessels

REN JIAN 9

REN JIAN 9 is a 2002 freight ship. The Coast Guard has recorded 24 inspections since 2003, most recently in August 2022, along with 8 deficiencies and 2 operational controls.

Records from 2003 to 2022. Most recent: inspection, 24 August 2022.

Built
2002
Last inspected
24 August 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9252230 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
613885
Flag
CHINA
—
Maury page id
psix-613885

Inspections, by type

…with no type recorded5
Years with a record 9 calendar years (2003–2022)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it41834 - Convention (Subpart B), Gross Ton
73732 - Displacement, Metric Ton
57240 - Dead Weight, Metric Ton
27093 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SEAPEAK CATALUNYA Tank Ship · MISLE 651580 · 11 October 2003 · activity 1929031

Inspection history · 24

24 August 2022 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7542328
9 January 2022 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7377463
3 January 2012 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4213831
27 July 2011 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4096616
2 December 2010 ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3898233
10 October 2008 PI Safety Exam · ISPS III Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3342321
18 July 2008 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3267204
15 May 2006 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2650077
2 April 2006 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2614620
26 November 2005 ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2540881
1 April 2005 PII Safety Exam · Ballast Water Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2324804
14 March 2005 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2310473
8 November 2004 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2236855
2 November 2004 Random ISPS/MTSA/PSC
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2232919
31 October 2004 Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2231833
17 May 2004 MTSA/ISPS Verification
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2070000
25 March 2004 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2030904
14 October 2003 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1927988
11 October 2003 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1929031
7 October 2003 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1922934
15 August 2003 Examination of Repairs
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1886743
15 August 2003 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1886766
4 April 2003 Ballast Water Examination · Annual Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1768229
4 April 2003 Security Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1768296

Deficiency record · 8

11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 24 August 2022 Resolved
Not less than 2 Life Buoys shall be provided with self activating smoke signals complying with the requirements of paragraph 2.1.3 of the code. PSCO observed a cracked self-activating smoke buoy on starboard side bridge wing. 20 SOLAS III/7.1.3 LSA CODE 2.1.3
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 September 2022
Resolution: Recieved report attesting to replacement
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 January 2022 Resolved
In a ship which oil fuel is used, the arraingment for the storage distribution and utilization of the oil fuel shall be such as to ensure safety of the ship and persosn on board and shall at least comply with the following provisions. PSCO observed excessive oil under generators #2 and #3. SOLAS(01) II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 January 2022
Resolved 9 January 2022
Resolution: Corrected on Spot
Navigation › Collision/Grounding Avoidance › Radar
Issued 27 July 2011 Resolved
27JUL11: Issued inbound Letter Of Deviation (LOD) for inoperable S-band Radar. SOLAS 74 (09 Cons.) V/19.2.7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2011
Resolution: Contract company completed repairs onboard and tested, found to be operating normally as per manufacturer''s specifications. As per Tech report recieved 30JUL2011
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 10 October 2008 Resolved
Vessel experienced fire while at sea in No. 5 cargo hold originating forom container below decks. Crew controlled fire using 61 of 210 CO2 bottles. Vessel does not have sufficient capacity remaining to be ready for immediate use.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 October 2008
Resolution: CO2 cylinders filled, system checked by technician/ RO. All sat.
Construction/Loadline › Hull › Transverse Frame
Issued 10 October 2008 Resolved
Vessel experienced fire while at sea in no. 5 hold raising concerns that the vessel's safety and integrity may have been compromised. Investigation by RO and survey must be conducted along with PSC Exam to determine extent of damage.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 October 2008
Resolution: RO conducted survey of vessel leaving two outstanding conditions of class. Vessel safe to proceed to sea.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 18 July 2008 Resolved
1420: There were oily rags collecting oil from leaks around the #2 SSG. This poses a minor fire hazard. SOLAS 04 Chap II-1 Reg 26.7. 10c
Due 18 July 2008
Resolved 18 July 2008
Resolution: Crew cleaned up oily rags while inspectors were onboard.
Engineering › Sea-water System (primary cooling) › Piping
Issued 2 April 2006 Resolved
One welded patch was discovered on the M/E sea water cooling line. SOLAS 74 amd. I/11 Correct deficiency prior to next US port after sailing foreign.
Action required: 705 - Other - as specified
Resolved 2 April 2006
Resolution: Repaired by the ship''''''''s crew.
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 2 April 2006 Resolved
Vessel's master is not reporting non-conformities to the DPA in accordance with ch. 9 of the ship's ISM Manual. SOLAS 74 amd. IX/3
Action required: 705 - Other - as specified
Resolved 2 April 2006
Resolution: Corrected while CG Inspector was onboard.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.