MAURY USCG vessel records Sign in
← All vessels

TORM MARY

TORM MARY is a 2002 tank ship. The Coast Guard has recorded 31 inspections since 2003, most recently in May 2020, along with 7 deficiencies and 8 operational controls.

Records from 2003 to 2020. Most recent: inspection, 27 May 2020.

Built
2002
Last inspected
27 May 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9246798 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V3904
618344
Flag
SINGAPORE
—
Maury page id
psix-618344

Inspections, by type

…with no type recorded12
Years with a record 11 calendar years (2003–2020)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it56198 - Displacement, Metric Ton
46349 - Dead Weight, Metric Ton
30128 - Convention (Subpart B), Gross Ton
11742 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAPT TKJ Towing Vessel · MISLE 191351 · 3 September 2004 · activity 2185530BUFFALO 405 Tank Barge · MISLE 634398 · 3 September 2004 · activity 2185530CAPT TKJ Towing Vessel · MISLE 191351 · 2 August 2004 · activity 2160664BUFFALO 405 Tank Barge · MISLE 634398 · 2 August 2004 · activity 2160664

Inspection history · 31

27 May 2020 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6962066
2 March 2020 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6918084
1 March 2020 COE-Offshore
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6918298
15 May 2019 Deficiency Check · ISPS II Exam · Ballast Water Examination · COE-Administrative · COC-CHEM & TVE Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6680196
7 November 2016 Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6033987
29 July 2016 ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5956474
16 October 2015 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5741201
5 August 2014 ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4943566
28 July 2008 COC-CHEM Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3281941
27 June 2007 MARPOL Annex V Examination · Ballast Water Examination · COC-CHEM Renew · ISPS II Exam · MARPOL Annex II Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2975769
13 February 2007 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2871465
8 February 2007 NPV Safety Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2869038
7 February 2007 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2868471
26 July 2006 MARPOL Annex I Examination · ISPS III Exam · COC-CHEM Annual · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2725445
14 June 2006 ILO-147 Exam · Random ISPS/MTSA/PSC · STCW 95 Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2679629
21 June 2005 COC-CHEM Renew
Type not classified · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2397659
18 January 2005 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2286022
13 November 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2240246
18 October 2004 Administrative Inspection
Administrative · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2223168
3 September 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2185530
2 August 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2160664
2 August 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2160743
31 May 2004 MTSA/ISPS Verification · Certificate of Compliance · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2083677
26 February 2004 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2027468
26 January 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1997563
25 January 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1992777
16 June 2003 Administrative Inspection
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1818577
9 May 2003 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1789806
7 May 2003 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1788533
7 May 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1789174
1 May 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1792850

Deficiency record · 7

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 May 2019 Resolved
Tankers shall be equipped with at least one portable instrument for measuring oxygen and one for measuring flammable vapor concentrations, together with a sufficient set of spares. Both portable instruments for measuring oxygen and flammable vapor concentrations are malfunctioning and a fixed system to measure these concentrations is not installed. A U.S. Coast Guard PSCO must clear this deficiency prior to conducting cargo operations.
Action required: 705 - Other - as specified
Resolved 17 May 2019
Resolution: Two new portable meters were brought on board. PSCO verified calibration and proper functioning of meters. Cargo tanks were randomly sampled with average oxygen of 2.6%.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 16 October 2015 Resolved
The marks shall be plainly visible. The vessel had two visible load line markings that made it difficult to determine the correct marking.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 October 2015
Resolution: 19OCT2015- Received, reviewed, and accepted photo documentation showing that the vessel painted both loadlines IAW its International Load Line cerificate.
Communications › Internal Communications System › Engine Order Telegraph System
Issued 7 February 2007 Resolved
Bridge engine order telegraph failed to keep engine in all stop after all stop command and positioning of the engine order telegraph to all stop. Class provided a written report to USCG stating that until repairs are completed, Maine Engine is to be operated in local engine room control only. The Pilot is comfortable transiting the vessel with this issue. Tugs will assist the vsl away from pier.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 February 2007
Resolution: Replacement provided by manufacturer in France this date.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 18 January 2005 Resolved
30mm crack between COT #6 stbd and BWT #4 stbd. Crack had previously been welded, however the weld has failed, requiring temporary repairs. Make permanent repairs prior to next US port.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 17 February 2005
Resolution: The minor crack between Cargo Oil Tank 6 starboard and Water Ballast Tank 4 starboard has now been re-welded. DNV has been on board the vessel and approved the repair.
Construction/Loadline › Hull
Issued 26 January 2004 Resolved
Vessel suffered a grounding while discharging unleaded gasoline. Vessel must have a dive survey of the hull, rudder, and propeller and must supply this office with the vessel's classification society survey report certifying that the vessel is fit for route and service.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2004
Resolution: Vessel submited a classification society, and satisfactory dive survey report to the USCG.
Deck/Cargo › Inert Gas System
Issued 7 May 2003 Resolved
Inert Gas System oxygen annalyzer is inoperative. Repairs are required prior to discharging of cargo.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2003
Resolution: Received report from Class attesting to repairs, system test and by in proper operation.
Fire Fighting › Structural Fire Protection - General
Issued 7 May 2003 Resolved
Galley has no installed fire protection system over the deep fat fryer/oven/griddle area as required by Solas. Repair to satisfaction of issuing authority of safety equipment prior to 6-7-03. LEGACY COMPONENT DESC: Cooking Area
Condition: Unknown
Due 7 June 2003
Resolved 9 May 2003
Resolution: System not required to have FF protection on fryer.

Ownership record