Records from 2003 to 2020. Most recent: inspection, 27 May 2020.
Inspection history · 31
27 May 2020
PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6962066
2 March 2020
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6918084
1 March 2020
COE-Offshore
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6918298
15 May 2019
Deficiency Check · ISPS II Exam · Ballast Water Examination · COE-Administrative · COC-CHEM & TVE Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6680196
7 November 2016
Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6033987
29 July 2016
ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5956474
16 October 2015
ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5741201
5 August 2014
ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4943566
28 July 2008
COC-CHEM Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3281941
27 June 2007
MARPOL Annex V Examination · Ballast Water Examination · COC-CHEM Renew · ISPS II Exam · MARPOL Annex II Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2975769
13 February 2007
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2871465
8 February 2007
NPV Safety Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2869038
7 February 2007
Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2868471
26 July 2006
MARPOL Annex I Examination · ISPS III Exam · COC-CHEM Annual · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2725445
14 June 2006
ILO-147 Exam · Random ISPS/MTSA/PSC · STCW 95 Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2679629
21 June 2005
COC-CHEM Renew
Type not classified · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2397659
18 January 2005
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2286022
13 November 2004
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2240246
18 October 2004
Administrative Inspection
Administrative · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2223168
3 September 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2185530
2 August 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2160664
2 August 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2160743
31 May 2004
MTSA/ISPS Verification · Certificate of Compliance · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2083677
26 February 2004
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2027468
26 January 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1997563
25 January 2004
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1992777
16 June 2003
Administrative Inspection
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1818577
9 May 2003
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1789806
7 May 2003
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1788533
7 May 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1789174
1 May 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1792850
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 May 2019
Resolved
Tankers shall be equipped with at least one portable instrument for measuring oxygen and one for measuring flammable vapor concentrations, together with a sufficient set of spares. Both portable instruments for measuring oxygen and flammable vapor concentrations are malfunctioning and a fixed system to measure these concentrations is not installed. A U.S. Coast Guard PSCO must clear this deficiency prior to conducting cargo operations.
Action required: 705 - Other - as specified
Resolved 17 May 2019
Resolution: Two new portable meters were brought on board. PSCO verified calibration and proper functioning of meters. Cargo tanks were randomly sampled with average oxygen of 2.6%.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 16 October 2015
Resolved
The marks shall be plainly visible. The vessel had two visible load line markings that made it difficult to determine the correct marking.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 October 2015
Resolution: 19OCT2015- Received, reviewed, and accepted photo documentation showing that the vessel painted both loadlines IAW its International Load Line cerificate.
Communications › Internal Communications System › Engine Order Telegraph System
Issued 7 February 2007
Resolved
Bridge engine order telegraph failed to keep engine in all stop after all stop command and positioning of the engine order telegraph to all stop. Class provided a written report to USCG stating that until repairs are completed, Maine Engine is to be operated in local engine room control only. The Pilot is comfortable transiting the vessel with this issue. Tugs will assist the vsl away from pier.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 February 2007
Resolution: Replacement provided by manufacturer in France this date.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 18 January 2005
Resolved
30mm crack between COT #6 stbd and BWT #4 stbd. Crack had previously been welded, however the weld has failed, requiring temporary repairs. Make permanent repairs prior to next US port.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 17 February 2005
Resolution: The minor crack between Cargo Oil Tank 6 starboard and Water Ballast Tank 4 starboard has now been re-welded. DNV has been on board the vessel and approved the repair.
Construction/Loadline › Hull
Issued 26 January 2004
Resolved
Vessel suffered a grounding while discharging unleaded gasoline. Vessel must have a dive survey of the hull, rudder, and propeller and must supply this office with the vessel's classification society survey report certifying that the vessel is fit for route and service.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2004
Resolution: Vessel submited a classification society, and satisfactory dive survey report to the USCG.
Deck/Cargo › Inert Gas System
Issued 7 May 2003
Resolved
Inert Gas System oxygen annalyzer is inoperative. Repairs are required prior to discharging of cargo.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2003
Resolution: Received report from Class attesting to repairs, system test and by in proper operation.
Fire Fighting › Structural Fire Protection - General
Issued 7 May 2003
Resolved
Galley has no installed fire protection system over the deep fat fryer/oven/griddle area as required by Solas. Repair to satisfaction of issuing authority of safety equipment prior to 6-7-03. LEGACY COMPONENT DESC: Cooking Area
Condition: Unknown
Due 7 June 2003
Resolved 9 May 2003
Resolution: System not required to have FF protection on fryer.