Records from 1987 to 2026. Most recent: inspection, 10 June 2026.
Inspection history · 41
10 June 2026
Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8397825
8 July 2025
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8179258
7 November 2024
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8032010
25 June 2024
Internal Structural Exam · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7942329
14 July 2023
Administrative Inspection · In-Service Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7742685
8 May 2023
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7683853
11 February 2022
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7394683
18 December 2021
Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 7370120
7 June 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7218644
12 January 2021
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7123149
21 October 2020
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7081756
12 November 2019
Administrative Inspection · Initial Certification · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6854169
23 September 2017
Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6274800
23 September 2017
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6291750
3 June 2016
MTSA Verification · Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5907337
23 November 2013
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4758342
30 May 2013
Industry Initiated Exam · Deficiency Check · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4606542
18 September 2012
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4448296
8 June 2010
Industry Initiated Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3762228
8 June 2010
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3762254
26 April 2010
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3725038
23 February 2009
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3422516
8 January 2008
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3132078
18 July 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2431400
3 September 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2185530
9 August 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2160734
2 August 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2160664
24 June 2004
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2109383
24 June 2004
MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2109458
9 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1962505
19 May 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 428798
9 February 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 57183
18 December 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 456267
3 February 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 39237
29 November 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 522334
20 June 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 40114
7 January 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 482779
24 November 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 675510
22 November 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 167487
10 July 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 38452
25 February 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 314845
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 July 2025
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Measures must be in place to prevent flammable or combustible liquid piping leaks from coming into contact with these components. Missing lagging on hot side of main diesel engines turbos.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2025
Resolved 21 August 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 July 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. 3 isolation valves missing for racor filters.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2025
Resolved 21 August 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 July 2025
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Starboard main engine displaying active fault.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2025
Resolved 21 August 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 July 2025
Resolved
The hose must be a lined commercial fire hose 15 meters (50 feet) in length, at least 40 millimeters (1.5 inches) in diameter, and fitted with a nozzle made of corrosion-resistant material capable of providing a solid stream and a spray pattern. Port side fire hose
found worn and with holes.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2025
Resolved 21 August 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 June 2024
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must be maintained to ensure proper operation.
Starboard main engine panel displayed five active faults including engine crankcase vent system, transmission oil temp, engine aux system, fuel level sensor, and rudder angle sensor.
Enact permanent repairs to the satisfaction of a USCG Marine Inspector. 46 CFR 143.205(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 June 2024
Resolution: Received satisfactory tech report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 June 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions.
Starboard main engine hydraulic line fitting from the reduction gear to the cooler was actively leaking onto the starter electrical cables creating a hazard.
Enact permanent repairs to the satisfaction of a USCG Marine Inspector.46 CFR 143.205(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2024
Resolution: Shipyard installed new hydraulic hose on oil cooler.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 25 June 2024
Resolved
The cognizant OCMI may require additional examinations of the vessel whenever he or she discovers or suspects damage or deterioration to hull plating or structural members that may affect the seaworthiness or fitness for the route or service of a vessel. These examinations may include a drydock examination, including:(1) An internal structural examination of any affected space of a vessel, including its fuel tanks;
Condition of the vessel requires in-water Internal Structure Examination by a USCG Marine Inspector within 30 days. 46 CFR 137.300(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2024
Resolved 19 July 2024
Resolution: Conducted ISE with deficiencies noted in new entry.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 25 June 2024
Resolved
An existing vessel may be deemed by the OCMI, or TPO, to be in compliance with this subpart provided that either:(a) The vessel is built, equipped, and maintained to conform to the rules of a recognized classification society appropriate for the intended service and routes, but not classed.
MIs noted wastage in the FWD and AFT voids of the longitudinal and transverse framing. Owner/operator shall enact permanent repairs at next dry dock, no later than 30NOV2024.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2024
Resolved 7 November 2024
Resolution: Witnessed satisfactory repairs.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 July 2023
Resolved
Electrical conductors passing though watertight bulkheads must be installed so that the bulkhead remains watertight. Vessel had two penetrations in the forward bulkhead of the engine room. Repair to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2023
Resolved 3 October 2023
Resolution: Rio marine attended vessel and replaced with putty with marine-grade hardening material.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 July 2023
Resolved
Alarms must be visible and audible at each operating station. Vessel did not have an audible bilge high level alarm. Repair or replace to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2023
Resolved 3 October 2023
Resolution: Rio marine attended vessel and reconnected wire to the bilge high level alarm buzzer.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 July 2023
Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. Vessel did not test or replace relief valves on their required interval. Repair or replace to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2023
Resolved 14 September 2023
Resolution: Provided new relief valves with spares.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 20 July 2023
Resolved
Machinery must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Vessel was missing flame impingement bowls under two fuel filters. Repair or replace to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2023
Resolved 23 August 2023
Resolution: Vessel has installed 02 flame impingement bowls for the Racor filters designed to have the bowls.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 July 2023
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. Switchboard in the engine room had two open wire penetrations on the bottom. Repair or replace to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2023
Resolved 23 August 2023
Resolution: 02 metallic grommets were installed in the openings.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 July 2023
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel did not have a record of fire extinguisher servicing. Provide service record to the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2023
Resolved 14 September 2023
Resolution: Provided firefighting servicing tech report, dated 07SEP2023.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 20 July 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on board under normal and emergency conditions. Generator did not have machinery guard installed in front of rotating belt. Repair or replace to the satisfaction of the attending Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2023
Resolved 23 August 2023
Resolution: Machinery guards were reinstalled on the generators.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 20 July 2023
Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must be maintained to ensure proper operation. Vessel had a pipe being supported by two metal hose clamps. Repair or replace to the satisfaction of the attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2023
Resolved 22 September 2023
Resolution: Pipe is supported via angle steel, welded to the deck and fastened via u-bolt.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 July 2023
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Vessels hertz meter was missing face plate reading stick. Repair or replace to the satisfaction of the attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2023
Resolved 22 September 2023
Resolution: Hertz meter was removed and blank cover was installed; switchboard has an additional hertz meter.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 April 2022
Resolved
46 CFR 142.330(b)
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges that alerts individuals in those spaces.
The smoke detectors in the berthing passageway and the galley spaces are inoperable and will not test.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2022
Resolved 6 May 2022
Resolution: Vessel replaced inop smoke detectors and installed additional detectors in other spaces.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 April 2022
Resolved
46 CFR 143.410(b)
Emergency lighting must be provided for all internal crew working and living areas.
Emergency lighting in the galley will not test, and the right side light is broken and hanging by the wires.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2022
Resolved 18 May 2022
Resolution: Vessel installed new emergency lighting in the galley.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 21 April 2022
Resolved
46 CFR 140.405(c)
The emergency duties and duty stations required by this section must be posted at each operating station and in a conspicuous location in visited by crewmembers.
There are no crew emergency assignments posted onboard the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2022
Resolved 11 May 2022
Resolution: Company created a crew duties chart and installed on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 21 April 2022
Resolved
46 CFR 141.315 refers to 46 CFR 199.176(b)
Each rigid life float must be marked as follows: Name of the vessel, name of the homeport, and capacity.
The life-float does not have any markings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2022
Resolved 6 May 2022
Resolution: Life float is labeled with the vessel's name.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 April 2022
Resolved
46 CFR 141.340(f)
Each lifejacket must be marked in block capital letters with the name of the vessel.
None of the lifejackets are marked with the vessel's name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2022
Resolved 6 May 2022
Resolution: All life jackets are labeled with the vessel's name.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 April 2022
Resolved
46 CFR 141.340(g)
Each lifejacket must have the following attachments and fittings: A light approved under series 161.012/161.112.
07 lifejackets had expired chemically activated lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2022
Resolved 6 May 2022
Resolution: Expired chemical lights were replaced with new ones.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 April 2022
Resolved
46 CFR 141.360(b)
Each life buoy on a towing vessel must: be marked in capital block letters with the name of the vessel.
02 life buoys were not marked with the vessels name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2022
Resolved 6 May 2022
Resolution: All life buoys are labeled with the vessel's name.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 21 April 2022
Resolved
46 CFR 140.705(b)
A towing vessel must carry current charts, maps, and nautical publications for the intended voyage.
Vessel does not have paper charts or a back-up system for electronic charts if the primary system fails.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2022
Resolved 20 June 2022
Resolution: Vessel is utilizing a approved alternate method via cell phone for nautical charts. The system allows for downloading of the charts to use for navigation without the need for cell service.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 21 April 2022
Resolved
46 CFR 143.220(b)
Piping and machinery components must be insulated.
Portions of exhaust on both MDEs is not insulated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2022
Resolved 20 May 2022
Resolution: Vessel installed insulation around the exposed portions of the exhaust and generator turbo.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 April 2022
Resolved
46 CFR 143.260(e)
Each remote valve control must be marked in clearly legible letters, at least 1 inch high, indicating the purpose of the valve and the way to operate it.
The emergency fuel shut-off valve has no markings.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2022
Resolved 6 May 2022
Resolution: Emergency fuel shut-off is permanently marked.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 April 2022
Resolved
46 CFR 142.230(c)
The frame or support of any semi-portable fire extinguisher with wheels must be welded or permanently attached to a bulkhead or deck.
The 160-B semi-portable is not secured/attached
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2022
Resolved 6 May 2022
Resolution: The 160-B semi-portable extinguisher has been attached to the railing on the starboard aft rail on the 2nd deck.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 April 2022
Resolved
46 CFR 143.205(a)
Machinery and electrical systems must designed and maintained for safe operation of the towing vessel.
Forward storage area has an uncovered electrical outlet.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2022
Resolved 6 May 2022
Resolution: A face plate has been installed onto the electrical outlet.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 21 November 2019
Resolved
No fire dampers for engine ventilation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2019
Resolved 21 November 2019
Resolution: Cleared and verified by attending MIs during COI inspection.
Documentation
Issued 25 February 1987
Resolved
PROVIDE A POLLUTION PLACARD ON BOARD IN ACCORDANCE WITH 33CFR155.450.
Condition: Unknown
Due 25 February 1987
Resolved 25 February 1987
Navigation
Issued 25 February 1987
Resolved
PROVIDE A COPY OF THE NAVIGATION RULES ON BOARD IN ACCORDANCE WITH 33CFR88.05.
Condition: Unknown
Due 25 February 1987
Resolved 25 February 1987
Accommodation/Occupational Safety
Issued 25 February 1987
Resolved
VESSEL IS EQUIPPED WITH AN INSTALLED TOILET AND WAS FOUND OPERATING WITH THE TYPE III MSD ON BOARD BYPASSED ALLOWING RAW SEWAGE TO DISCHARGE DIRECTLY OVERBOARD IN VIOLATION OF 33CFR159.7.
Condition: Unknown
Due 25 February 1987
Resolved 25 February 1987
Lifesaving
Issued 25 February 1987
Resolved
PROVIDE A COAST GUARD APPROVED RING BUOY ON BOARD IN ACCORDANCE WITH 46CFR25.25-5(D).
Condition: Unknown
Due 25 February 1987
Resolved 25 February 1987