MAURY USCG vessel records
← All vessels

WARRIOR

Built
1943
Last inspected
24 September 2008
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 24 September 2008
…with no type recorded10
…past their stated due date6
Operational controls None recorded without a removal date
Years with a record 5 calendar years (1992–2008)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

5111268
WDB6462
Flag
UNITED STATES
Maury page id
psix-61952

Documentation record

Tonnage as PSIX records it146 - Regulatory (Subpart C or D), Gross Ton
99 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 16 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each, 7 without one; operational controls, none recorded without a removal date; 3 other vessels inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SEI 180-6 Tank Barge · MISLE 51979 · 23 March 2005 · activity 2318060SEI 180-7 Freight Barge · MISLE 54140 · 23 March 2005 · activity 2318060MARINERS HARBOR Freight Barge · MISLE 54615 · 6 August 2004 · activity 2160803

Inspection history · 16

24 September 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3438454
28 February 2008 Type not recorded
No type recorded · Station St Petersburg · USCG Southeast District (CGD-SE) · Activity 3155703
28 February 2008 Examination of Repairs · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3156147
21 February 2008 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3156120
27 July 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3008927
23 July 2007 Uninspected Other
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3005801
19 April 2007 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2914382
30 March 2005 Uninspected Other · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2323204
23 March 2005 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2318060
7 March 2005 Hawser Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2305634
2 March 2005 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2302764
11 August 2004 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2163429
6 August 2004 Type not recorded
No type recorded · USCGC YELLOWFIN (WPB 87319) · USCG Southeast District (CGD-SE) · Activity 2158325
6 August 2004 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2160803
18 June 1992 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 660783
17 June 1992 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 120294

Deficiency record · 10

Engineering › Diesel Engine (propulsion-direct drive) › Pump, Positive Displacement
Issued 28 February 2008 Resolved
Properly repair water pump and seal.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 February 2008
Resolution: Witnessed satisfactory test of the water pump.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 28 February 2008 No resolution recorded
Replace or remove expired fire exitinguishers.
Action required: 705 - Other - as specified
Due 28 March 2008 — due date passed with no resolution recorded
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 23 July 2007 No resolution recorded
Vessel is missing logbook enteries for required tests and inspections.
Condition: Improper/Lack of Maintenance
Due 23 July 2007 — due date passed with no resolution recorded
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 23 July 2007 No resolution recorded
Missing the company policy for chemical testing program
Condition: Improper/Lack of Maintenance
Due 28 July 2007 — due date passed with no resolution recorded
Documentation › Logs/Records › Declaration of Inspection
Issued 23 July 2007 No resolution recorded
Vessel is missing their D.O.I's. Vessel was instructed to keep all fuel/oil transfers for at least 30 days.
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Fire Fighting › Fire Pumps › Location
Issued 23 July 2007 Resolved
Vessel is missing fixed or portable fire pump.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2007
Resolution: Vessel purchased a portable fire pump and ran the pump with Coast Guard on board.
Operations/Management › Drills/Instruction › Activating General Alarm
Issued 23 July 2007 Resolved
Vessels general alarm audible not working in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2007
Resolution: Vessel fixed audible alarm in engine room. Tested with Coast Guard present.
Documentation › Markings/Placards › Warning Signs
Issued 23 July 2007 No resolution recorded
Vessel is missing a Noise hazard sticker around the entry area of the engine room.
Condition: Improper/Lack of Maintenance
Due 28 July 2007 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 July 2007 No resolution recorded
Vessel has wires jury rigged all through-out. Junction boxes and fuse panels are missing covers.
Condition: Improper Installation
Due 6 August 2007 — due date passed with no resolution recorded
Electrical › Lighting (service) › Lighting Fixture
Issued 23 July 2007 No resolution recorded
Vessel is missing lights and covers through out.
Condition: Improper/Lack of Maintenance
Due 28 July 2007 — due date passed with no resolution recorded

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.