MAURY USCG vessel records Sign in
← All vessels

SPRING TIME

SPRING TIME is a 1964 freight ship. The Coast Guard has recorded 22 inspections since 2003, most recently in October 2024, along with 38 deficiencies — 2 with no resolution recorded — and 4 operational controls.

Records from 2003 to 2024. Most recent: inspection, 21 October 2024.

Built
1964
Last inspected
21 October 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

6503626 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
621806
Flag
CAMBODIA
—
Maury page id
psix-621806

Inspections, by type

…with no type recorded10
Years with a record 4 calendar years (2003–2024)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it247 - Regulatory (Subpart C or D), Gross Ton
678 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SEACOR ENDEAVOR Offshore Supply Vessel · MISLE 466654 · 9 October 2003 · activity 1971341

Inspection history · 22

21 October 2024 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8022135
29 February 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7872397
21 May 2005 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2364016
25 April 2005 PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2342202
1 February 2005 Type not recorded
No type recorded · Tactical Law Enforcement Team South · Activity 2317384
8 March 2004 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2020159
2 March 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2016459
27 February 2004 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2014353
23 February 2004 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2011278
23 February 2004 Administrative Inspection
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2011397
23 February 2004 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2012075
22 January 2004 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1999511
1 December 2003 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1956534
30 October 2003 Periodic Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1939163
9 October 2003 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1971341
7 October 2003 Periodic Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1923186
12 September 2003 Periodic Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1936940
15 August 2003 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1920355
9 July 2003 Periodic Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1850251
16 June 2003 Security Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1818936
14 June 2003 Type not recorded
No type recorded · Station Point Allerton · USCG Northeast District (CGD-NE) · Activity 1817658
16 May 2003 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1796432

Deficiency record · 38

Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 21 May 2005 Resolved
Provide a Chief Engineer.
Due 25 May 2005
Resolved 21 May 2005
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 25 April 2005 Resolved
Vsl to have a valid COFR.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2005
Documentation › Certificates/Documents › International Load Line Certificate
Issued 25 April 2005 Resolved
Vsl to have a valid Load Line Cert.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2005
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 25 April 2005 No resolution recorded
Vsl to provide proof of a vaild CCSSC cert issued by Flag/Class prior to enering U.S. waters.
Action required: 15 - Rectify deficiencies by next port
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 25 April 2005 No resolution recorded
Vsl to provide proof of valid ISM docs prior to entering U.S. waters
Action required: 15 - Rectify deficiencies by next port
Documentation › Certificates/Documents
Issued 8 March 2004 Resolved
A valid Caribbean Cargo Ship Safety Code certificate (CCSSC). (Current certificate is a Panamanian Certificate issued to a Honduran flagged vessel in February 2004 based on a survey completed in Aug 2003.)
Action required: 705 - Other - as specified
Due 29 February 2024
Resolved 29 February 2024
Resolution: 29FEB2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since '04. vessel returned to US (San Juan, 2342202). From activity: 2020159
Personnel › Certificates/Documents/Licenses
Issued 8 March 2004 Resolved
Provide crew licenses with valid Honduran Endorsements for all licensed officers.
Action required: 705 - Other - as specified
Due 29 February 2024
Resolved 29 February 2024
Resolution: 29FEB2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since '04. vessel returned to US (San Juan, 2342202). From activity: 2020159
Fire Fighting › Fire Pumps
Issued 8 March 2004 Resolved
Fire pump not operational under load. Make permanent and proper repairs to the satisfaction of the designated flag representative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 February 2024
Resolved 29 February 2024
Resolution: 29FEB2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since '04. vessel returned to US (San Juan, 2342202). From activity: 2020159
Pollution Prevention/Response › Prevention Equipment
Issued 8 March 2004 Resolved
No proper containment around any of the oil fill, sounding or vent piping. Make permanent and proper repairs to the satisfaction of the designated flag rep. prior to bunker operations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 29 February 2024
Resolution: 29FEB2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since '04. vessel returned to US (San Juan, 2342202). From activity: 2020159
Navigation › Electronic Positioning
Issued 8 March 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 February 2024
Resolved 29 February 2024
Resolution: 29FEB2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since '04. vessel returned to US (San Juan, 2342202). From activity: 2020159
Communications › Radio Communications
Issued 8 March 2004 Resolved
Battery charger not properly mounted or wired. Make permanent and proper repairs to the satisfaction of the designated flag representative.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 February 2024
Resolved 29 February 2024
Resolution: 29FEB2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since '04. vessel returned to US (San Juan, 2342202). From activity: 2020159
Documentation › Certificates/Documents
Issued 8 March 2004 Resolved
Prove proper operation of radios once new Station License has been obtained. Make permanent and proper repairs to the satisfaction of the designated flag representative.
Action required: 705 - Other - as specified
Due 29 February 2024
Resolved 29 February 2024
Resolution: 29FEB2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since '04. vessel returned to US (San Juan, 2342202). From activity: 2020159
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 22 January 2004 Resolved
GLASS COVERS FOR EDISON FUSES ON ELECTRICAL PANEL IN PILOT HOUSE ARE MISSING.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2004
Resolution: GLASS COVERS HAVE BEEN REPLACED.
Electrical › Electric Generation Source (service)
Issued 22 January 2004 Resolved
REPAIR ENGINE ROOM VENTILATION FANS (BOTH PORT & STBD). LEGACY COMPONENT DESC: Number of Sources
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2004
Resolution: BOTH FANS HAVE BEEN REPAIRED & ARE NOW OPERATING.
Electrical › Electric Generation Source (emergency) › Generator
Issued 22 January 2004 Resolved
REPAIR EMERGENCY GENERATOR VENTILATION FAN.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2004
Resolution: EMERGENCY GENERATOR VENTILATION FAN HAS BEEN REPAIRED & IS OPERABLE.
Electrical › Electric Supply System (service)
Issued 22 January 2004 Resolved
REPAIR ACCOMODATION SPACE VENTILATION FAN.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2004
Electrical › Electric Generation Source (emergency)
Issued 22 January 2004 Resolved
MUST REPAIR OR REPLACE SMOKE DETECTION SYSTEM (ENGINE ROOM)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2004
Resolution: INSTALLED NEW SMOKE DETECTORS.
Electrical › Electric Generation Source (emergency)
Issued 22 January 2004 Resolved
PROVE PROPER OPERATION OF GENERAL ALARM FROM BRIDGE.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2004
Resolution: GENERAL ALARM HAS BEEN TESTED FROM BRIDGE & IS NOW OPERATING.
Engineering › Bilge Water Management System
Issued 22 January 2004 Resolved
PROVE PROPER OPERATION OF BILGE PUMPING SYSTEM IN ALL COMPARTMENTS.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2004
Resolution: BILGE PUMPING SYSTEM HAS BEEN PROVEN TO SUCCESSFULLY OPERATE.
Pollution Prevention/Response
Issued 22 January 2004 Resolved
REMOVE EXCESS OIL AND SLUDGE FROM ENGINE ROOM BILGES AND DISPOSE OF PROPERLY ON SHORE. LEGACY COMPONENT DESC: ENGINE ROOM BILGE
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2004
Resolution: EXCESS OIL AND SLUDGE FROM ENGINE ROOM BILGES HAVE BEEN DISPOSED OF PROPERLY ON SHORE VIA PROOF OF USE OF A LOCAL CONTRACTING COMPANY.
Communications › Radio Communications
Issued 22 January 2004 Resolved
PROVIDE AN EFFECTIVE MEANS OF 2 WAY COMMUNICATIONS FROM THE BRIDGE TO THE STEERING FLAT FOR USE WHEN STEERING IN EMERGENCY MODE.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2004
Resolution: VESSEL HAS PROVIDED AN EFFECTIVE MEANS OF 2 WAY COMMUNICATIONS FROM THE BRIDGE TO THE STEERING FLAT FOR USE WHEN STEERING IN EMERGENCY MODE.
Lifesaving › Lifejacket/PFD (General)
Issued 22 January 2004 Resolved
PROVIDE LIFEJACKET WITH OPERABLE WATERLIGHT,WHISTLE AND REFLECTIVE TAPE FOR EACH CREWMEMBER PLUS FOUR SPARES IN THE SAME CONDITIONS TO BE LOCATED IN A MARKED LOCATION NEAR THE LIFE BOAT. ALL STRAPS SHOULD BE INTACT AND IN SERVICABLE CONDITION. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2004
Resolution: LIFEJACKET REQUIREMENTS HAVE BEEN MET.
Lifesaving › Buoyant Smoke Signals
Issued 22 January 2004 Resolved
PROVIDE SIX ORANGE SMOKE DAY SIGNALS. LEGACY COMPONENT DESC: SIX ORANGE SMOKE DAY SIGNALS
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2004
Resolution: VESSEL HAS PROVIDED THESE ITEMS.
Fire Fighting › Firemans Outfit › Air Hose
Issued 22 January 2004 Resolved
PROVIDE COMPLETE FIREMAN'S OUTFIT INCLUDING FIRE RESISTANT GLOVES, WATER AND HEAT RESISTANT CLOTHING, RIGID HELMET WITH FACESHIELD, FLASHLIGHT, FIRE AXE, RUBBER BOOTS, 50 FT. FIREPROOF LIFELINE AND AN AIR SOURCE. (SCBA)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2004
Resolution: THE VESSEL HAS PROVIDED A COMPLETE FIREMAN''S OUTFIT INCLUDING FIRE RESISTANT GLOVES, WATER AND HEAT RESISTANT CLOTHING, RIGID HELMET WITH FACESHIELD, FLASHLIGHT, FIRE AXE, RUBBER BOOTS, 50 FT. FIREPROOF LIFELINE AND AN AIR SOURCE. (SCBA)
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 22 January 2004 Resolved
REFILL/REPLACE PKP FIRE EXTINGUISHER EXPENDED DURING ENGINE ROOM FIRE AT SEA ON 19 JAN 04.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2004
Resolution: VESSEL REPLACED PKP FIRE EXTINGUISHER EXPENDED DURING ENGINE ROOM FIRE AT SEA ON 19 JAN 04.
Personnel › Training › Fire Fighting Basic
Issued 22 January 2004 Resolved
CONDUCT AND LOG FIRE AND ABANDON SHIP DRILLS WITH A COAST GUARD MARINE INSPECTOR IN ATTENDANCE.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2004
Resolution: SATISFACTORILY CONDUCTED AND LOGGED FIRE AND ABANDON SHIP DRILLS WITH A COAST GUARD MARINE INSPECTOR IN ATTENDANCE.
Fire Fighting › Miscellaneous Items
Issued 22 January 2004 Resolved
PROVIDE AND POST WRITTEN EMERGENCY INSTRUCTIONS FOR CREW RESPONSE TO ON BOARD FIRE AND ABANDON SHIP EMERGENCIES. LEGACY COMPONENT DESC: WRITTEN EMERGENCY INSTRUCTIONS
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2004
Resolution: VESSEL HAS PROVIDED AND POSTED WRITTEN EMERGENCY INSTRUCTIONS FOR CREW RESPONSE TO ON BOARD FIRE AND ABANDON SHIP EMERGENCIES.
Accommodation/Occupational Safety › Potable Water System
Issued 22 January 2004 Resolved
ENSURE ADEQUATE SUPPLY OF POTABLE WATER ON BOARD FOR DURATION OF THE NEXT VOYAGE. LEGACY COMPONENT DESC: WATER IS NOT SUITABLE FOR DRINKING
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2004
Resolution: 120 GALLONS OF BOTTLED WATER HAS BEEN PROVIDED TO THE VESSEL''S CREW FROM THE VESSEL''S OWNER.
Navigation
Issued 22 January 2004 Resolved
REPAIR WINDSHIELD WIPER MOTOR AND CLEARVIEW SCREEN IN THE PILOT HOUSE. LEGACY COMPONENT DESC: WINDSHIELD WIPER & CLEARVIEW SCREEN
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2004
Resolution: VESSEL REPLACED WINDSHIELD WIPER MOTOR & FIXED THE CLEARVIEW SCREEN IN THE PILOT HOUSE.
Pollution Prevention/Response › Prevention Equipment
Issued 22 January 2004 Resolved
PROVIDE AT LEAST 1 PUMP INSTALLED TO DISCHARGE OILY MIXTURES THROUGH A FIXED PIPING SYS.(33 CFR 155.350) TO RECEPTION FACILITIES. PIPING MUST HAVE AT LEAST 1 OUTLET ACCESSIBLE FROM THE WEATHER DECK WITH A SHORE CONNECTION OR ADAPTER THAT MEETS THE DIMENSIONS AND SPECS DESCRIBED IN 33CFR 155.430 A-C LEGACY COMPONENT DESC: BILGE DISCHARGE SYSTEM
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 October 2024
Resolution: Cleared
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 22 January 2004 Resolved
ADD ADDITIONAL RUNGS TO LIFE BOAT BOARDING LADDER TO ALLOW EGRESS FROM BOAT DECK. (33 CFR 160.111 C)
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 October 2024
Resolution: Cleared
Construction/Loadline › Markings
Issued 30 October 2003 Resolved
Deck water line mark not painted. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 November 2003
Resolution: VSL HAS CLEARY MARKED THE DECK WATER LINE.
Lifesaving › Buoyant Smoke Signals
Issued 30 October 2003 Resolved
Expiration dates missing from bouyant smoke light signals attached to lifebouys.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 November 2003
Resolution: EXPIRATION DATES ON BOUYANT SMOKE SIGNAL LIGHTS HAVE BEEN CLEARY MARKED.
Fire Fighting › Ventilation Systems
Issued 30 October 2003 Resolved
Flame screens on all fuel oil tank vents missing/wasted.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 November 2003
Resolution: VSL REPLACED FLAME SCREENS ON ALL FUEL OIL TANK VENTS.
Engineering
Issued 30 October 2003 Resolved
Engine room bilge contains excess ammounts of oil.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 November 2003
Resolution: VSL REMOVED EXCESS AMOUNTS OF OIL FROM ENGINE ROOM BILGE.
Electrical › Electric Generation Source (emergency)
Issued 27 October 2003 Resolved
WHILE CONDUCTING A PRIORITY ONE PSC EXAM, THE EMERGENCY GENERATOR WAS INOPERABLE DUE TO A BAD STARTING BATTERY, AFTER OBTAINING NEW BATT, GENERATOR STILL WOULD NOT START. LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2003
Resolution: GENERATOR WAS TESTED UNDER LOAD, ALL SAT.
Construction/Loadline › Penetrations
Issued 27 October 2003 Resolved
COMBING HOLDING GASKET MATERIAL IN PLACE WAS WASTED AND GASKET WOULD NOT STAY IN PLACE. LEGACY COMPONENT DESC: Weld
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 November 2003
Resolution: VSL REPLACED COMBING HOLDING GASKET MATERIAL, TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Construction/Loadline › Hull
Issued 9 July 2003 Resolved
Issued COTP order described in narrative. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Due 30 July 2003
Resolved 15 August 2003
Resolution: Examined two inserts plates in the side shell in the engine room port side including pressure hose test and found satisfactory .

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.