This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it19343 - Convention (Subpart B), Net Ton 83975 - Displacement, Metric Ton 70146 - Dead Weight, Metric Ton 41679 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel
Behind this panel: 13 inspections, each with its date, unit and type; 2 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 13
13 July 2020In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7004119
18 June 2020Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6979845
3 May 2020COC-TVE Renew · MARPOL Annex VI Survey · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6947206
5 February 2019Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6620049
23 January 2019ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6613879
7 December 2018COE-Administrative
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6593499
28 October 2018COE-Dockside
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6569631
22 October 2018Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6565905
9 January 2018Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6334548
8 February 2017Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6079991
21 July 2016COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5947054
15 January 2016Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5798352
5 January 2016ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5788443
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 January 2019Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, contructed and installed as to withstand the maximum allowable working stresses to which it may be subjected. Inspector observed multiple steam system leaks at the following locations:
-steam line gasket at cargo tank 1 STBD
-steam pipe leak #2 cargo tank STBD
-steam pipe leak #6 cargo tank STBD
-steam pipe supply to HFO tank
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2019
Resolved 5 February 2019
Resolution: Vessel submitted class report attesting to the repairs listed in deficiency.
0613 - Stowage of lifeboats - Maintenance of conditions after survey - the condition of the ship and its equipment shall be maintained whenever an accident occurs which affects the safety of its life-saving appliances or other equipment. PSCO observed aft securing gripe break during operational test of Starboard life boat. 74 SOLAS 14 con. I/11
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 January 2016
Resolved 14 January 2016
Resolution: PSC NOLA received a class report from LR satisfying the requirement.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.