Records from 2003 to 2020. Most recent: inspection, 13 July 2020.
Inspection history · 40
13 July 2020
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7004119
18 June 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6979845
3 May 2020
COC-TVE Renew · MARPOL Annex VI Survey · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6947206
5 February 2019
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6620049
23 January 2019
ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6613879
7 December 2018
COE-Administrative
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6593499
28 October 2018
COE-Dockside
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6569631
22 October 2018
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6565905
9 January 2018
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6334548
8 February 2017
Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6079991
21 July 2016
COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5947054
15 January 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5798352
5 January 2016
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5788443
23 June 2012
COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4353139
12 July 2011
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4078607
12 July 2011
PI Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4078923
11 July 2011
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4118856
10 July 2011
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4077173
10 July 2011
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4077207
6 October 2010
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3862081
2 July 2009
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3518703
28 January 2009
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3401524
12 August 2008
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3296566
28 July 2008
COC-TVE Annual · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3278871
2 May 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3196311
2 May 2008
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3205413
28 April 2008
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3194117
1 November 2007
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3091287
25 June 2007
ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2973903
1 March 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2876892
31 July 2006
COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2724500
27 July 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2727050
23 June 2005
ISPS II Exam · COC-TVE Renew
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2400603
22 May 2005
Random ISPS/MTSA/PSC
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2364698
21 May 2005
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2364452
6 July 2004
PII Safety Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2123671
4 July 2004
PII Safety Exam · ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2120723
17 May 2004
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2070242
17 May 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2070402
8 June 2003
Certificate of Compliance · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1812403
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 January 2019
Resolved
Every steam pipe and every fitting connected thereto through which steam may pass shall be so designed, contructed and installed as to withstand the maximum allowable working stresses to which it may be subjected. Inspector observed multiple steam system leaks at the following locations:
-steam line gasket at cargo tank 1 STBD
-steam pipe leak #2 cargo tank STBD
-steam pipe leak #6 cargo tank STBD
-steam pipe supply to HFO tank
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2019
Resolved 5 February 2019
Resolution: Vessel submitted class report attesting to the repairs listed in deficiency.
Lifesaving › Launching Appliances › Release Mechanism
Issued 5 January 2016
Resolved
0613 - Stowage of lifeboats - Maintenance of conditions after survey - the condition of the ship and its equipment shall be maintained whenever an accident occurs which affects the safety of its life-saving appliances or other equipment. PSCO observed aft securing gripe break during operational test of Starboard life boat. 74 SOLAS 14 con. I/11
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 January 2016
Resolved 14 January 2016
Resolution: PSC NOLA received a class report from LR satisfying the requirement.
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 12 July 2011
Resolved
1410 Sufficient power for going astern shall be provided to secure proper control of the ship in all normal circumstances. While departing the port of Long Beach, the main engine did not respond to dead slow astern commands twice from the bridge and once from engine control room while operating on MGO. 74 SOLAS (2004 cons.) II-1/28. 10ac
Action required: 705 - Other - as specified
Due 12 July 2011
Resolved 12 July 2011
Resolution: Fuel rack setting increased from 43% to 47% as per MAN technical consult by ship. Class (Lloyds) Surveyor & CG MIs verified proper operation by testing from bridge, ECR, & local controls.
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 12 July 2011
Resolved
2535 The company and ship shall comply with the requirements of the ISM. The company shall establish procedures, plans, and instructions, including checklists as appropriate for key shipboard operations. Current fuel changeover procedures for operations on MGO contain settings below that which sustain operation of the main engine in all commands. 74 SOLAS (2009) IX/3 & ISM Reg 7.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 August 2011
Resolution: Received class report attesting to the correction to the changeover procedures and updated set point for the governor on the affected engines.
Navigation › Collision/Grounding Avoidance › Relative Motion Plotting Equipment
Issued 2 May 2008
Resolved
03May2008 After notification that the vessel was unable to rectify the deficiency in this port, the vessel was granted an Outbound Letter of Deviation. The vessel is still required to submit inbound deviation requests at future U.S. ports until the equipment is repaired.
Vessel is unable to repair speed log until next dry dock.
Action required: 705 - Other - as specified
Due 4 May 2008
Resolved 12 August 2008
Resolution: VESSEL PROVIDED CLASS REPORT ATTESTING TO THE CORRECTION OF THE DEFICIENCY. CLASS REPORT PROVIDED BY MARELEQ S.A. MARINE ELECTRONIC EQUIPMENT ATHENS, GREECE TEL +30 210 9711.332
Navigation › Collision/Grounding Avoidance › Relative Motion Plotting Equipment
Issued 2 May 2008
Resolved
Received inbound deviation request for inoperable Speed log.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 12 August 2008
Resolution: VESSEL PROVIDED CLASS REPORT ATTESTING TO THE CORRECTION OF THE DEFICIENCY. CLASS REPORT PROVIDED BY MARELEQ S.A. MARINE ELECTRONIC EQUIPMENT ATHENS, GREECE TEL +30 210 9711.332
Navigation › Collision/Grounding Avoidance › Radar
Issued 1 November 2007
Resolved
S BAND RADAR MALFUNCTIONING
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 November 2007
Resolved 7 November 2007
Resolution: RECIVED AND APPROVED CLASS REPORT