Records from 2003 to 2025. Most recent: inspection, 7 June 2025.
Inspection history · 31
7 June 2025
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8154123
3 April 2025
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8104570
29 March 2025
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8099069
20 March 2025
PSC B · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8096713
20 September 2024
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8006444
7 July 2024
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7951347
2 July 2024
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7946592
17 February 2024
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7866875
13 February 2024
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7864882
23 November 2023
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7828900
21 November 2023
PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7825271
17 November 2023
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7826414
5 January 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7617372
27 December 2022
Ballast Water Examination · PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7612442
8 August 2014
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4948390
20 June 2014
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4894486
21 July 2012
Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4385557
26 December 2011
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4212191
17 July 2005
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2429781
7 June 2005
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2384886
8 February 2005
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2288912
6 February 2005
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2287434
2 February 2005
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2285525
21 December 2004
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2262947
6 October 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2461611
5 October 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2214717
16 August 2004
PII Safety Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2168140
4 July 2004
ISPS II Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2121183
24 January 2004
Ballast Water Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1992123
2 August 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1864376
2 August 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1865129
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 March 2025
Resolved
The machinery, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed leaking pipe on cascade tank and leaking pump for #1 feed water pump to the boiler.
74 SOLAS (04)
II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2025
Resolved 3 April 2025
Resolution: BV attested to the flanges being replaced on the cascade tank and the #1 feed water pump to the boiler was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 29 March 2025
Resolved
The provision of safe means of access to and throughout the ship, and the satisfactory physical condition of [...] handrails. PSCO observed broken handrails on landing platform of main engine.
ILO-147/PWSA
46 USC 70002
ILO-147 pg. 45, 3-b
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2025
Resolved 3 April 2025
Resolution: BV attested to the handrail being properly secured and bolted in on the landing platform.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 March 2025
Resolved
The machinery, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed leaks on quick closing valve to #2 service generator.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 March 2025
Resolved 29 March 2025
Resolution: PSCO observed tighting of gland on quick closing valve.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 March 2025
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: Means shall be provided to control leaks of flammable liquids. PSCO observed evidence of old fuel oil leaks on FO pump for cylinders 9 and 13 on ME, inlet valve for No. 2 fuel oil purifier, and flange on FO supply to incinerator.
74SOLAS(14) II-2/ 4.1 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2025
Resolved 26 March 2025
Resolution: tie-downs were tightened, lagging replaced, stem packing tightened, oil cleaned. Pumps tested/witnessed by class surveyor and remain leak free.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 20 March 2025
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. PSCO observed hydraulic oil leaks on the No.1 steering gear.
74SOLAS(04) II-1/26.1 16AC
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2025
Resolved 26 March 2025
Resolution: seepage from gasket of pilot valve rectified by tightening holding bolts.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 20 March 2025
Resolved
To assist in casualty investigations ships when engaged on international voyages, subject to the provisions of Reg. 1.4, shall be fitted with a voyaged data recorder(VDR)as follows; ships, other than passenger ships, of 3,00 gross tonnage and upwards constructed on or after 1 July 2002. PSCO was informed by vessel even that the PCB unit is not operational, preventing voyage data transfer to the float free unit.
74SOLAS(20) V/20.1.4 16ac
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2025
Resolved 26 March 2025
Resolution: shore side tech replaced junction box damaged by water
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 20 March 2025
Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. PSCO observed 2 load lines on Port side due to worn paint.
66ICLL (Prot88) Reg 8 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 March 2025
Resolution: crew repainted lines as per ILLC
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 20 March 2025
Resolved
Oil residue (sludge) may be disposed of directly from the oil reside (sludge) tank(s) to reception facilities through the standard discharge connection referred to in regulation 13, or to any other approved means of disposal of oil residue (sludge), such as... other acceptable means which shall be annotated in 3.2 of the Supplement to IOPP Certificate Form A or B. PSCO observed evaporation being used as other acceptable means, this method was not approved item 3.2 of IOPP Supplement.
MARPOL I/ 12.2 40ac
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 March 2025
Resolution: IOPP supplement Form A updated to reflect evaporation method approval
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 20 March 2025
Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power required by Regulation II-1/ 42 & 43, as appropriate. PSCO observed two non- operational emergency lights in the vicinity of the STBD survival craft muster station.
74SOLAS(20) III/ 11.4 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 20 March 2025
Resolution: New light bulbs were installed and shown to work.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 2 July 2024
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. The design shall have regard to materials used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected and the environmental conditions on board. PSCO observed portable air duct connecting from engine room ventilation duct to air intake on No 4 diesel generator.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 July 2024
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 2 July 2024
Resolved
Every ship of 100 gross tonnage and above, and every ship which is certified to carry 15 or more persons, and fixed or floating platforms shall carry a garbage management plan which the crew shall follow. PSCO observed multiple oil buckets filled with engine oil next to the main engine.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 2 July 2024
Resolved
"THE MACHINERY, BOILERS, AND OTHER PRESSURE VESSELS ASSOCIATED PIPING SYSYEMS AND FITTINGS SHALL BE OF A DESIGN AND
CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED SALL BE SO INSPTALLED AND PROTECTED AS TO REDUCE A MINIMUM ANY DANGER TO PERSONS ON BOARD...." PSCO OBSERVED PORTABLE AIR DUCT CONNECTING FROM ENGINE ROOM VENTILATION DUCT TO AIR INTAKE ON NO. 4 DIESEL GENERATOR. VESSEL MUST REPLACE THE COVER RING ON THE TURBOCHARGER EXAHUST GAS INLET.
74 SOLAS (04) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 September 2024
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 27 December 2022
Resolved
The second means of starting, hydraulic accumulator, failed to start emergency generator after multiple attempts.
74SOLAS(2004 cons)II-I/44.2 (CODE 17AC)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2022
Resolution: Received Class report
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 20 June 2014
Resolved
74 SOLAS (04 CONS) II-1/17-1 & 17.2: The arrangement and efficiency of the means for closing any opening in the shell plating shall be consistent with its intended purpose and the position in which it is fitted and to the satisfaction of the administration. Lube oil was discharged from the stern tube due to unknown causes. 60ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2014
Resolution: Received satisfactory Class Report from Class NKK attesting to proper repair. See attached Class Report.
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 2 February 2005
Resolved
AIS MALFUNCTIONING
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 March 2005
Resolution: Fax received notification of new AIS transponder supplied by manufacturer.