Records from 2016 to 2026. Most recent: inspection, 17 February 2026.
Documentation record
Registered dimensions (L × B × D)61.0 ft × 15.0 ft × 8.0 ft
Registered tonnagegross 49 / net 39
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTHEODORE PETERSON · POMPANO BEACH, FL, UNITED STATES · built 2003
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portFORT LAUDERDALE, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 February 2026 · expires 31 March 2027
Service, as the file records itTank Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it49 - Simplified, Gross Ton
39 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
17 February 2026
Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8313212
24 July 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8193746
11 July 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7954906
2 July 2024
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7942605
3 October 2023
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7840323
16 February 2023
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8008971
25 January 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7627012
9 June 2022
Damage Survey · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7472869
3 February 2022
Drydock Exam · Administrative Inspection · Cargo Tank Internal · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7390904
31 August 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7302547
20 November 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7105921
18 July 2019
Drydock Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6753881
11 July 2019
COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6732437
4 October 2018
MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6554533
4 October 2017
MTSA Verification · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6281730
16 August 2017
Deficiency Check · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6242704
2 February 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6100411
11 August 2016
MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5970760
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 July 2024
Resolved
Boilers, main and auxiliary machinery, and piping systems shall conform to the requirements of subchapter F (Marine Engineering) of this chapter, except as otherwise provided for in this subchapter.
At each inspection for certification the marine inspector shall conduct such tests and inspections of the main propulsion and auxiliary machinery and of its associated equipment as he feels necessary to check safe operation. MI discovered fuel filter housing for Main Diesel Engine missing drain plug.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2024
Resolved 11 July 2024
Resolution: replaced fuel filter housing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 2 July 2024
Resolved
Boilers, main and auxiliary machinery, and piping systems shall conform to the requirements of subchapter F (Marine Engineering) of this chapter, except as otherwise provided for in this subchapter.
At each inspection for certification the marine inspector shall conduct such tests and inspections of the main propulsion and auxiliary machinery and of its associated equipment as he feels necessary to check safe operation. MI discovered fuel filter housing for Auxilliary Diesel Engine missing drain plug.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2024
Resolved 11 July 2024
Resolution: Replaced fuel filter housing.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 6 February 2023
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years... If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate.
Absence of FCC Safety Radiotelephony Certificate onboard. Obtain valid certificate.
47 CFR §80.903
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2023
Resolved 24 February 2023
Resolution: Received digital copy of valid FCC Radiotelephony Cert.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 6 February 2023
Resolved
Electric installations on vessels must ensure...protection of passengers, crew, other persons, and the vessel from electrical hazards. Dead-end wire discovered in bow-thruster space. Remove dead-end wire.
46 CFR §111.01-1(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2023
Resolved 24 February 2023
Resolution: Unused electrical junction box removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 February 2023
Resolved
...the marine inspector shall examine the tank tops and bilges in the fireroom and engineroom to see that there is no accumulation of oil which might create a fire hazard. Excess oily bilge water discovered in engine room. Remove oily bilge water from bilges.
46 CFR §31.10-50
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2023
Resolved 28 February 2023
Resolution: Invoice provided for engine room cleaning.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 16 August 2017
Resolved
Vessel experienced fire within exhaust pipeing. Vessel must provide technician's report prior to operations.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 August 2017
Resolution: Vessel did not have a fire as reported in the CG 2692. Crew member had mistakingly identified the waving reflection of the sun through the aux engine exhaust pipe as a flame. No damage was identified.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 11 August 2016
Resolved
Rudder ram is currently hitting auxiliary exhaust during operation. Repair exhaust line and provide proper support in way of steering gear.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 August 2016
Resolved 17 August 2016
Documentation › Logs/Records › MIS Form
Issued 11 August 2016
Resolved
Consortium MIS reports must be available onboard. -46 CFR 16.260
Action required: 705 - Other - as specified
Due 25 August 2016
Resolved 11 August 2016
Engineering › Steering Gear System › Hydraulic Hose
Issued 11 August 2016
Resolved
Excessive oil leaks on hoses stbd side overhead in engine room. Clean oil.
Action required: 705 - Other - as specified
Due 25 August 2016
Resolved 17 August 2016
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 August 2016
Resolved
Replace wing nuts on battery connections with permanent connections. -46 CFR 111.15
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 August 2016
Resolved 17 August 2016
Resolution: Wingnuts replaced.