PETERSON 3

PETERSON 3 is a 2003 tank ship. The Coast Guard has recorded 32 inspections since 2003, most recently in May 2026, along with 46 deficiencies and 3 casualty investigations between 2011 and 2023.

Records from 2003 to 2026. Most recent: inspection, 13 May 2026.

Built
2003
Last inspected
13 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI6165
654514
Flag
UNITED STATES
367076010 (licence lapsed)
Maury page id
psix-654514

Inspections, by type

…with no type recorded3
Years with a record 17 calendar years (2003–2026)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)61.0 ft × 15.0 ft × 8.0 ft
Registered tonnagegross 49 / net 39
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTHEODORE PETERSON · POMPANO BEACH, FL, UNITED STATES · built 2003
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portFORT LAUDERDALE, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 8 July 2026 · expires 31 July 2027
Service, as the file records itTank Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it49 - Simplified, Gross Ton
39 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC7736MMSI 367076010 · expired · voluntarily equipped · granted 10 November 2005, cancelled 16 January 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PETERSON 2 Tank Ship · MISLE 641378 · 16 February 2023 · activity 8008971

Inspection history · 32

13 May 2026 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8372341
3 June 2025 Annual Inspection · Cargo Tank Internal · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8150862
29 March 2024 COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7886995
25 March 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7888588
28 June 2023 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7725878
16 February 2023 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8008971
12 December 2022 Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7615795
1 March 2022 Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7405037
8 November 2021 Annual Inspection · MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7616725
20 November 2020 MTSA Verification · Administrative Inspection · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7104464
29 July 2020 Administrative Inspection · Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7019357
14 November 2019 Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6859272
17 September 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6818717
8 February 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6628184
11 July 2018 In-Service Inspection · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6475795
29 January 2018 Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6345202
30 January 2017 Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6079319
2 November 2015 DAPI Audit · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5755356
6 August 2015 Cargo Tank Internal · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5207387
18 May 2012 Deficiency Check · Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4317277
17 May 2012 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4314375
9 February 2012 Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4241155
8 November 2010 COI Inspection · MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3887233
4 November 2010 Internal Structural Exam · Hull Examination · Cargo Tank Internal
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3884591
27 January 2010 Annual Inspection · MTSA Verification · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3670694
14 November 2008 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3362840
29 October 2008 Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3353477
9 October 2008 Hull Examination · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3341260
31 January 2008 Annual Inspection · MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3139254
5 February 2007 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2867005
10 June 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2094059
29 December 2003 Initial Certification · Initial Construction-Excluding Oversight · MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2525457

Deficiency record · 46

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2026 Resolved
The type, size, location and arrangement of portable and semi portable extinguishers shall be as set forth in subpart 34.50. MI identified 01: 40-B portable extinguisher on the port side engine room not properly charged.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 29 May 2026
Resolution: Fire extinguisher replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 June 2025 Resolved
Each self-propelled vessel must be provided with a power-driven pump, or pumps connected to the bilge main as required by table 1 to § 56.50-55(a). Operator could not prove proper operation on required bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 June 2025
Resolved 6 June 2025
Resolution: Bilge pump repaired as needed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 June 2025 Resolved
Each individual bilge suction must be fitted with a suitable strainer having an open area of not less than three times that of the suction pipe. Mid compartment did not have strainer connected.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2025
Resolved 24 June 2025
Resolution: Bilge suction screen installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 June 2025 Resolved
Gears, couplings, flywheels, and all rotating machinery capable of injuring personnel must be provided with adequate covers or guards. Main propulsion and generator are missing belt guards.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2025
Resolved 24 June 2025
Resolution: Both belts guards, reinstalled.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 March 2024 Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in § 176.500(b)(1) [annual inspection within 3 months before or after each anniversary date] and your Certificate of Inspection must be endorsed. Vessel did not complete 2024 annual COI inspection w/i 3 months before or after anniversary date. 46 CFR 176.502
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2024
Resolution: Completed renewal COI, all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 July 2018 Resolved
Cutlass bearing is worn. Rewnew cutlass bearing.
Action required: 705 - Other - as specified
Due 11 July 2018
Resolved 30 July 2018
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 November 2015 Resolved
Provide guards for engine equipment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 November 2015
Resolved 29 January 2016
Resolution: Guards were installed for engine equipment.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 November 2015 Resolved
Properly terminate nav light wiring (running lights).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 November 2015
Resolved 29 January 2016
Resolution: Nav lights are properly terminated into secure conduit.
Engineering › Thrusters › Piping
Issued 4 November 2015 Resolved
Secure bow thruster leaking hydraulic line
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 November 2015
Resolved 29 January 2016
Resolution: Bow thruster hydraulic line leak was secured.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 18 May 2012 Resolved
Prior to operation make repair/renew STBD aft spud or provide a plan for equal level of safety to operate vessel without STBD aft spud. Once spud is repaired/renewed make available for USCG inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2012
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 9 February 2012 Resolved
Due to change of management, amend the VRP, including list of QI's.
Due 23 February 2012
Resolved 22 February 2012
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 9 February 2012 Resolved
Due to change of management, designate a new DER for the chemical testing program and provide documentation for supervisory (min 60 minute training) drug awareness training (EAP). 46CFR16.401.
Due 23 February 2012
Resolved 22 February 2012
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 8 November 2010 Resolved
Service discharged B-II portable fire extinguisher.
Action required: 705 - Other - as specified
Resolved 12 November 2010
Resolution: Corrected on the spot.
Stability › Watertight Integrity › General
Issued 4 November 2010 Resolved
Make bolts connecting helm chair to deck watertight.
Action required: 705 - Other - as specified
Due 12 November 2010
Resolved 12 November 2010
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 29 October 2008 Resolved
Replace flex hose on main engine wet exhaust
Due 12 November 2008
Resolved 4 November 2008
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 29 October 2008 Resolved
Double clamp flex hose on main engine wet exhaust water supply line.
Due 12 November 2008
Resolved 4 November 2008
Engineering › Freshwater System (cylinder head cooling) › Piping
Issued 29 October 2008 Resolved
Repair or replace bracket on Aux. Engine freash water crossover pipe.
Due 12 November 2008
Resolved 4 November 2008
Engineering › Bilge Water Management System › Strainer
Issued 30 January 2008 Resolved
Install bilge strainer in tank void space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2008
Engineering › Bilge Water Management System › Strainer
Issued 30 January 2008 Resolved
Install bilge strainer in forward peak.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2008
Engineering › Steering Gear System › Hydraulic Hose
Issued 30 January 2008 Resolved
Replace fuel pump hydraulic flex hose located in engine room.
Action required: 705 - Other - as specified
Due 7 February 2008
Resolved 7 February 2008
Documentation › Manuals/Policy Documentation › Tank Vessel Loading Information
Issued 5 February 2007 Resolved
Provide a diagram of cargo piping valves in transfer book.
Due 5 March 2007
Resolved 6 February 2007
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 5 February 2007 Resolved
Repair/replace rudder angle indicator.
Due 5 March 2007
Resolved 6 February 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 5 February 2007 Resolved
Service or prove servicing on all fire extingiushers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2007
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 5 February 2007 Resolved
Provide log of monthly safety drills.
Due 5 March 2007
Resolved 6 February 2007
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Securing Means
Issued 5 February 2007 Resolved
Secure the BV fire extinguisher so it can't roll around.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2007
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 5 February 2007 Resolved
Provide copy of annual cargo piping pressure test.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 February 2007
Documentation › Certificates/Documents › Stability Letter
Issued 3 November 2005 Resolved
Provide dead weight and stability information.
Action required: 705 - Other - as specified
Due 3 December 2005
Resolved 20 December 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 3 November 2005 Resolved
Provide certs on cargo piping fittings elbows.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 November 2005
Documentation › Markings/Placards › Warning Signs
Issued 27 July 2005 Resolved
Provide warning signs per 46 CFR 35.30-1 and security signs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 July 2005 Resolved
Provide metal hanger for electrical wiring and hydraulic hoses in overhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2005
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 27 July 2005 Resolved
Permently mount rudder angle indiator arm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 27 July 2005 Resolved
Provide protective covers on exhaust pipes.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 27 July 2005 Resolved
Provide metal hanger for exhaust pipe.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2005
Engineering › Steering Gear System › Linkage
Issued 27 July 2005 Resolved
Tighten bolts on steering sysem.
Action required: 15 - Rectify deficiencies by next port
Resolved 3 November 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 July 2005 Resolved
Provide proper wiring for bow runningl ights (14 gauge).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 25 July 2005 Resolved
Provide properly charged BI and BII fire extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 25 July 2005 Resolved
Prove proper operation of flaot light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 25 July 2005 Resolved
Prove proper operartion of rudder anle indicator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 25 July 2005 Resolved
Prove proper operation of pressure relief valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Documentation › Markings/Placards › Oil Discharge Placard
Issued 25 July 2005 Resolved
Provide oil pollution warning placard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 25 July 2005 Resolved
Provide deck lightling at transfer station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 25 July 2005 Resolved
Prove leak tight exhaust manifold on Aux. Engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 25 July 2005 Resolved
Provide manufacture cert on hose of pressure test or perform test.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 25 July 2005 Resolved
Provide fire control plans per 46 CFR 35.10-3
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2005
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 25 July 2005 Resolved
Be prepared to demostrate the vessel during an under way sea trial for up to two hours.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 July 2005
Electrical › Electrical Distribution System (service) › Panelboard
Issued 29 December 2003 Resolved
Provide cover, labels for 12 v DC panel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005

Casualty record · 3

25 April 2011Routine · role: Involved in a Marine Casualty · activity 4000369
17 May 2012Routine · role: Involved in a Marine Casualty · at CSXT RR, DANIA CUT-OFF CANAL · activity 4314375
16 February 2023Routine · role: Involved in a Marine Casualty · at SW 1ST STREET BRIDGE, MIAMI RIVER · activity 8008971
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

PROVIDER II (2011–2012). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.