Records from 2003 to 2026. Most recent: inspection, 5 June 2026.
Documentation record
Registered dimensions (L × B × D)195.0 ft × 35.0 ft × 12.0 ft
Registered tonnagegross 687 / net 687
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · PORT ALLEN, LA, UNITED STATES · built 2003
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 3 October 2025 · expires 30 November 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it687 - Simplified, Gross Ton
687 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 42
5 June 2026
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8387739
7 May 2025
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8135271
5 March 2024
Internal Structural Exam · Cargo Tank Internal · Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7874621
27 March 2023
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7657639
9 March 2023
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7648271
6 January 2022
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7376425
30 November 2020
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7104124
7 February 2020
MTSA Verification · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6904673
7 May 2019
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6678840
10 December 2018
Internal Structural Exam · Cargo Tank Internal · COI Inspection · MTSA Verification · Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6595217
24 October 2017
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6293939
19 October 2016
Periodic Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6025954
23 June 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5916267
13 January 2016
MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5796968
17 July 2015
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5187042
15 July 2015
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5185442
19 June 2015
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5157537
28 May 2015
In-Service Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5148349
2 February 2015
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5062923
5 January 2015
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5048066
24 December 2014
Load Line/Change of Employment · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5043942
10 November 2014
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5021430
9 November 2014
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5021503
28 October 2013
Hull Examination · Cargo Tank Internal · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4742689
7 October 2013
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4730642
27 July 2012
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4392529
27 February 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4252054
30 April 2010
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3727618
24 April 2009
Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3459698
2 May 2008
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3197463
9 April 2008
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3180714
23 April 2007
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2913940
2 May 2006
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2635768
30 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2504750
31 August 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2480332
28 June 2005
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2406183
14 June 2005
MTSA Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2390653
4 April 2005
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2326220
29 July 2004
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2149483
27 May 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2080099
30 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1998990
20 October 2003
Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1941783
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 October 2016
Resolved
Vessel shall install guard to protect personnel around alternator/alternator belt.
Action required: 705 - Other - as specified
Due 19 November 2016
Resolved 24 October 2017
Electrical › Electrical Distribution System (service) › Cable
Issued 19 October 2016
Resolved
Renew busted conduit in way of overfill alarm, port side aft on vessel
Action required: 705 - Other - as specified
Due 19 November 2016
Resolved 24 October 2017
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 13 January 2016
Resolved
Provide two B-II fire extiguishers prior to transferring or loading cargo.
Condition: Improper Installation
Due 15 January 2016
Resolved 13 January 2016
Deck/Cargo › Cargo Stowage › General
Issued 13 January 2016
Resolved
Provide securing fork for cargo tank #3 hatch.
Condition: Improper Installation
Due 15 January 2016
Resolved 13 January 2016
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 9 June 2015
Resolved
Drawings for proposed cargo pipe system modifications shall be submitted for approval and hydrostatic pressure testing conducted after approval. Piping must be segregated from approved cargo system until such time as these requirements are complete.
Action required: 705 - Other - as specified
Due 28 June 2015
Resolved 14 July 2015
Resolution: Corrected
Engineering › Gasoline Engine (auxiliary) › Alternator (4 cycle)
Issued 9 April 2008
Resolved
Installed alternator is not UL approved or stamped. Appears to be of automotive type. Vsl limited to loading and discharging grade E cargoes only until fixed and inspected by attending marine inspector.
Condition: Improper Installation
Due 7 May 2008
Resolved 2 May 2008
Resolution: Correct alternator installed.
Construction/Loadline › Hull › Hull Plating
Issued 23 April 2007
Resolved
Noted 2ft x 1ft inset on the starboard aft quarter approx 4ft above the waterline. Damage to be repaired at next yard period.
Condition: Unknown
Due 23 April 2007
Resolved 28 May 2009
Resolution: Inset repaired
Electrical › Electrical Distribution System (service) › Cable
Issued 20 October 2003
Resolved
Vsl did not have approved plans for electrical installations or prime mover installation.
Condition: Unknown
Due 29 June 2004
Resolved 29 July 2004
Resolution: vsl rep demonstrated plan removal