STARSHIP

STARSHIP is a 2003 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2016, most recently in June 2025, along with 63 deficiencies and 1 casualty investigation in 2011.

Records from 2011 to 2025. Most recent: inspection, 17 June 2025.

Built
2003
Last inspected
17 June 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 June 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDQ5913
659984
Flag
UNITED STATES
Maury page id
psix-659984

Documentation record

Registered dimensions (L × B × D)82.2 ft × 20.0 ft × 6.0 ft
Registered tonnagegross 73 / net 49
ITC dimensions (L × B × D)82.2 ft × 20.0 ft × 6.0 ft
ITC tonnagegross 178 / net 63
BuilderTSS FABRICATING INC · LA CROSSE, WI, UNITED STATES · built 2003
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMIAMI, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 22 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it178 - Convention (Subpart B), Gross Ton
73 - Regulatory (Subpart C or D), Gross Ton
63 - Convention (Subpart B), Net Ton
49 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

14 inspections, each with its date, unit and type; 63 deficiencies with the resolution recorded against each; 1 other recorded name, with years; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

17 June 2025 Administrative Inspection · Annual Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8157724
25 November 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8039495
12 July 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7956762
13 June 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7938998
13 June 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7714519
31 October 2022 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7586784
7 April 2022 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7426883
7 March 2021 Administrative Inspection · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7151593
13 October 2020 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7075952
7 April 2020 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6939407
23 April 2019 COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6656673
9 May 2018 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6410289
25 April 2017 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6132591
13 April 2016 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 5854814

Deficiency record · 63

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 June 2025 Resolved
A fire hose with a nozzle must be attached to each fire hydrant at all times. 2nd Deck fire hose found to be holed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 22 July 2025
Resolution: Hoses replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 June 2025 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). One of the required two bilge pumps found inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 12 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 June 2025 Resolved
Control of the main steering gear, including control of any necessary associated devices (motor, pump, valve, etc.), must be provided from the operating station. Power driven main steering pump is not operating when turned on from the bridge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2025
Resolution: Identified faulty switch. Replaced. Tested satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 17 June 2025 Resolved
The engine head, block, and exhaust manifold must be water-jacketed and cooled by water from a pump that operates whenever the engine is operating. Main generator heat exchanger wasted and holed leaking approximately 1 gallon per minute.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2025
Resolution: Wasted housing material cropped and renewed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 June 2025 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. High water level alarm panel at operating station is not working properly. An extra crew member is required on vessel to monitor bilges unit deficiency is corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 July 2025
Resolution: Replaced panel with new
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 17 June 2025 Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The markings required by this section must be made in clearly legible letters of the Latin alphabet or Arabic or Roman numerals not less than four inches in height. Vessel's name is not on the bow.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 22 July 2025
Resolution: Name installed
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 17 June 2025 Resolved
Each potable water tank shall be provided with a means of drainage and, if it is equipped with a manhole, overflow, vent, or a device for measuring depth of water, provision shall be made to prevent entrance into the tank of any contaminating substance. Water tank fill missing cap and vent screen. 21 CFR 1250.82(C)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 12 September 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 June 2025 Resolved
Waste receptacles. Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. All waste bins on vessel are made of combustible plastic material.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 22 July 2025
Resolution: Replaced with non combustible cans
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 17 June 2025 Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who meets the following requirements: (1) Where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license. Vessel captain did not have a FCC marine radio operator permit. 47 CFR 80.159(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 12 September 2025
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 17 June 2025 Resolved
Except as noted in paragraph (c) of this section, stations in the maritime service must be licensed by the FCC either individually or by fleet. FCC station license is registered to the vessel's old owner. 47 CFR 80.13(a)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 12 September 2025
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 17 June 2025 Resolved
No marine employer may engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. 1 Captain and 1 Deckhand were missing from DAPI test list.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 22 July 2025
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 17 June 2025 Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members. Public address system was not working
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 12 September 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 June 2025 Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by table 1 to § 181.500(b) and other provisions of this section. Vessel is missing extinguisher for engine room and pantry/bar area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 12 September 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 June 2025 Resolved
A vessel at anchor shall exhibit where it can best be seen in the fore part, an all-round white light. Anchor light not working
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 12 September 2025
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 June 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. Required publications were missing
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 12 September 2025
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 17 June 2025 Resolved
Lakes, bays, and sounds, and rivers routes. A vessel on a lakes, bays, and sounds, or rivers route must carry: (1) Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and (2) Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Distress signals on vessel were expired.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 22 July 2025
Resolution: Replaced with new
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 June 2025 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Portable light at operating station not working
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 July 2025
Resolved 22 July 2025
Resolution: Provided working light
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 June 2025 Resolved
Valves for removing water or impurities from diesel fuel in water traps or strainers are permitted. These valves must be provided with caps or plugs to prevent fuel leakage. Racor fuel filter for main generator equipped with drain valve but missing cap.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 12 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 June 2025 Resolved
In systems where flexible hoses are permitted, two clamps must be on each end of the hose. The cooling hose on the steering system is missing a clamp.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 22 July 2025
Resolution: Hose clamp installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 June 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Belt on starboard engine for bilge pump PTO loose and belt for port engine jacket water pump loose.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 12 September 2025
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 June 2025 Resolved
A vessel must carry either a First Aid Kit that meets the requirements of 46CFR199.175(b)(10) or a kit with equivalent contents and instructions. FA kit must meet the requirements of ISO 188.13:2006(E). First Aid kit was missing items.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 22 July 2025
Resolution: Replaced with new
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 June 2025 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible to the crew and passengers. Placard was missing on second deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 22 July 2025
Resolution: Plaquared installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 June 2025 Resolved
The number and identification of the items stowed inside and their sized must be marked in clearly legible letters and numbers on each container. Letters and numbers must be at least 2 inches high. Storage location was not marked legibly.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 22 July 2025
Resolution: Location marked
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 June 2025 Resolved
A vessel must carry one floating waterlight. Lifebouy waterlight inop. Replace.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 22 July 2025
Resolution: Battery replaced
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 17 June 2025 Resolved
Each light fixture globe, lense or diffuser must have a guard. All florescent lights below deck were secured with zip ties and did not have guards.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 12 September 2025
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 17 June 2025 Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen corrosion resistant wire of at least 30 x 30. The flame screen was missing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 12 September 2025
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 17 June 2025 Resolved
Portable fire extinguishers must be inspected and maintained IAW NFPA 10. Vessel did not have log of monthly fire extinguisher checks.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 12 September 2025
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 17 June 2025 Resolved
Man over board drills and training shall be logged. Vessel did not have proof of completion of MOB drills and training.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 22 July 2025
Resolution: Drills completed
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 17 June 2025 Resolved
Fire firefighting drills and training shall be logged. Vessel did not have proof of completion of fire fighting drills and training.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2025
Resolved 22 July 2025
Resolution: Drills completed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 July 2024 Resolved
Failure to meet requirements of 46 CFR Part 16
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2026
Resolution: DAPI updated, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 June 2024 Resolved
46 CFR 46.180.70:A vessel must have one or more ring life buoys.02 lifebouys have deteriorated grab lines. Repair or replace to Marine Inspector satisfaction.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 July 2024
Resolved 14 June 2024
Resolution: Life rings replaced, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 June 2024 Resolved
46 CFR 182.420:Engine cooling, all engines must be water cooled. Primary generator has a pinhole leak in Heat exchanger. Repair/Replace to the satisfation of Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 14 June 2024
Resolution: Coolant pipe replaced, all sat.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 13 June 2024 Resolved
46 CFR 185.728 (f):Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. Master shall ensure drills are being logged IAW CFR
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 14 June 2024
Resolution: Drill logs updated, all sat.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 13 June 2024 Resolved
46 CFR 185.524 (d):Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2024
Resolved 14 June 2024
Resolution: Drill logs updated, all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 June 2024 Resolved
46 CFR 16.260:Employers must maintain records of chemical tests and must make these records available to Coast Guard officials upon request. Only Master and one deckhand were on Consortium. All crew need to be in in full compliance on the consortium. Submit updated consortium with a Master and 2 deckhands in full compliance.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2024
Resolved 18 July 2024
Resolution: All deckhands were added to the consortium, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 June 2023 Resolved
Each floating water light… must be attached to the lanyard with a corrosion resistant clip. Replace floating water light battery and attach to the ring buoy via lanyard and clip. 46 CFR 180.70(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2023
Resolution: Proof of item correction recieved.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 June 2023 Resolved
Fire hazards to be minimized. Correct fuel leaks for aux generator's fuel strainers and isolation valves. 46 CFR 177.405(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2023
Resolution: Proof of item correction recieved.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 June 2023 Resolved
A vessel of more than 65ft in length must carry a minimum of three life buoys. Renew deteriorated ring buoy lines or replace ring buoys. 46 CFR 180.70
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2023
Resolution: Proof of item correction recieved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 June 2023 Resolved
A bilge suction must be fitted with a suitable strainer. Install strainer in aft compartment. 46 CFR 182.510(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2023
Resolution: Proof of item correction recieved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 June 2023 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment. Clean all check valves for bilge suction and perform operational testing. 46 CFR 182.500(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2023
Resolution: Proof of item correction recieved.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 June 2023 Resolved
A vessel must carry either a first aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents. Obtained proper first aid kit. 46 CFR 184.710
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2023
Resolution: Proof of item correction recieved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 June 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety and emergency conditions. Charge or renew (if necessary) electrical equipment for starting propulsion machinery. Perform testing of machinery remotely form the operating station. 46 CFR 183.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2023
Resolution: Proof of item correction recieved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 7 April 2022 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, some of the overhead insulation is saturated with oil. Remove and replace insulation with approved material. 46 CFR 176.830(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2022
Resolved 21 April 2022
Resolution: All insulation was removed and replaced with new.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 April 2022 Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Strainers must be leak free. Aft generator had a leak on Raicor housing. Replace necessary parts and test for leaks. 46 CFR 182.455(b)(6)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2022
Resolution: Vessel replaced parts. No leaks found.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 April 2022 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection. Stbd valve wasn't fully closing when pulling from emergency shutoff. Adjust until valve is fully close. 46 CFR 182.455 (b)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2022
Resolution: Vessel adjusted valve. Test Sat
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 April 2022 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, must be in satisfactory condition. Center fuel tank supply valve is leaking. Fix and test. 46 CFR 176.830(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2022
Resolution: Vessel tighten valve. No leaks found.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 April 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to, protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Remove all temporary extension cords and lights from Engine Room and Steering Compartment. 46 CFR 183.200(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2022
Resolution: Vessel removed all temporary extension cords and lights.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 April 2022 Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel... Mount and secure anchor windlass batteries to prevent shifting. 46 CFR 183.350(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2022
Resolved 21 April 2022
Resolution: All batteries were secured with approved brackets and straps.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 April 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to, protect vessel from electrical hazards, clean corrosion on battery terminals. 46 CFR 183.200 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2022
Resolved 21 April 2022
Resolution: Vessel cleaned and protected all battery terminals onboard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 April 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to, protect vessel from electrical hazards, clean corrosion on battery terminals. 46 CFR 183.200 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2022
Resolved 21 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 April 2022 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from machinery failure, Air conditioning pump is leaking, replace parts and test. 46 CFR 182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2022
Resolved 21 April 2022
Resolution: Vessel replaced pump with new one. Test Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 April 2022 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from machinery failure, Forward generator water pump is leaking. Replace parts and test. 46 CFR 182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2022
Resolved 21 April 2022
Resolution: Vessel replaced pump gasket. Test Sat
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 7 April 2022 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from machinery failure, remove plastic zip-ties from generator exhaust blanket. 46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2022
Resolution: Zip ties were replaced with metal wire.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 7 April 2022 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system, Both engine room vents aren't closing. Adjust and test 46 CFR 182.465(h)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2022
Resolution: Ventilation pull handles were lube and vessel added foam in between vents. Test Sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 April 2022 Resolved
Each ring life buoy on a vessel must: (1) Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, life rings grab lines are deteriorating. Replace with new life ring. 46 CFR 180.70 (b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2022
Resolved 8 April 2022
Resolution: Vessel acquired new life rings.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 7 April 2022 Resolved
Medical certificates issued to all other mariners will be issued for a maximum period of 5 years. Provide medical certificates for all MMC holders. 46 CFR 10.301 (b)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2022
Resolved 5 May 2022
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 7 April 2022 Resolved
Abandon ship, man overboard drills, Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Provide logbook with all drills records. 46 CFR 185.520/524
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2022
Resolved 5 May 2022
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 7 April 2022 Resolved
Radio telephony safety certificate wasn't on-board at the time of inspection. Provide this office with certificate. Vessel is restricted to 1000 FT from shore until certificate is provided. 46 CFR 80.903
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2022
Resolved 5 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 7 April 2022 Resolved
Each flare carried to meet this section must be stowed in one of the following: (1) A portable watertight container marked as required by § 185.614 of this chapter, carried at the operating station; Replace and mark new container. 46 CFR 180.68(e)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 April 2022
Resolved 21 April 2022
Resolution: Vessel replaced container with new. All Sat
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 25 March 2021 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fized fas entringuishing system. Engine room ventilation louvers were not closing. 46CFR182.465(h)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 April 2021
Resolved 25 March 2021
Resolution: Crew members conducted repairs on and demonstrated proper operation of ventilation louvers.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 April 2019 Resolved
Stern light was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2019
Resolved 17 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 23 April 2019 Resolved
Oil pressure gauge port side inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2019
Resolved 17 May 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 April 2019 Resolved
Drills are not being recorded as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 May 2019

Casualty record · 1

2 October 2011Routine · role: Involved in a Marine Casualty · activity 4165820
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

PARADISE LADY (2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.