Records from 2009 to 2026. Most recent: inspection, 26 June 2026.
Inspection history · 32
26 June 2026
Hull Examination · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8402848
8 May 2026
Administrative Inspection · MSP Additional Oversight - Risk Assessment · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8369176
19 March 2026
Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8328600
3 September 2025
Damage Survey · Administrative Inspection · Internal Structural Exam · Examination of Repairs · Vessel Attendance · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8207427
20 August 2025
Administrative Inspection · Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8216014
10 June 2025
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8166614
21 October 2024
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8026596
6 June 2024
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7927139
17 November 2023
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7826470
16 May 2023
Deadweight Survey · In-Service Inspection · Examination of Repairs · Hull Examination · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7689890
10 April 2023
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7664441
12 October 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7575790
5 May 2022
DAPI Audit · MTSA Verification · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7443706
9 November 2021
In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7346094
20 September 2021
Internal Structural Exam · Hull Examination · Deficiency Check · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7295158
5 August 2021
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7278236
9 June 2021
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7219240
8 April 2020
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6936953
18 December 2019
Administrative Inspection · In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6876580
12 November 2019
Internal Structural Exam · Damage Survey · Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6855455
22 August 2019
Administrative Inspection · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6784421
24 November 2018
Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6585810
7 October 2018
COI Inspection · MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6554164
2 October 2018
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6553282
21 September 2018
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6545442
24 August 2018
Internal Structural Exam · Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6521773
6 June 2018
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6434952
25 July 2017
Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6220074
9 June 2017
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6170270
12 April 2017
Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6122668
27 December 2016
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6069512
23 June 2016
Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5908029
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 March 2026
Resolved
Vessel reported suffering a coolant leak on the forward starboard engine while departing Key West on 14 Mar 2026. Replace ruptured coolant line prior to using the forward starboard engine (aft starboard and both port engines are operational).
Action required: 705 - Other - as specified
Resolved 19 March 2026
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 6 June 2024
Resolved
A fire control plan must be posted on the vessel in a location that is accessible and visible to all passengers.
MI observed vessel's newest version of the fire control plan was not posted on board.
46 CFR 116.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2024
Resolved 7 June 2024
Resolution: Vessel rep provided photos of newly posted fire control plan with approval from MSU Morgan City.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 6 June 2024
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced.
MI observed several pieces of retro reflective material on vessel's life floats that were severely deteriorated.
Renew and replace to satisfaction of marine inspector.
46 CFR 115.808(b)
Action required: 10 - Deficiency Rectified
Due 6 June 2024
Resolved 6 June 2024
Resolution: MI observed renewal and replacement of deteriorated retro reflective material on life floats.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 6 June 2024
Resolved
The instructions supplied by the manufacturer must contain directions for each of the following: (17) a statement as follows: The EPA standards state that in freshwater lakes, freshwater reservoirs or other freshwater impoundments whose inlets or outlets are such as to prevent the ingress or egress by vessel traffic subject to this regulation, or in rivers not capable of navigation by interstate vessel traffic subject to this regulation, marine sanitation devices certified by the U.S. Coast Guard installed on all vessels shall be designed and operated to prevent the overboard discharge of sewage, treated or untreated, or of any waste derived from sewage...
33 CFR 159.59(b)(17)
MI observed an instruction and warning placard near the vessel's sewage overboard discharge valve was missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2024
Resolved 12 June 2024
Resolution: Vessel rep provided photos of new sewage overboard discharge warning and instructional placards.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 6 June 2024
Resolved
The light must be a floating waterlight approved under approval series 161.010 or a standard specified by the Commandant.
46 CFR 117.175(f)(4)
MI observed 01 floating waterlight was inoperable. The battery was replaced by an approved type and corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 6 June 2024
Resolved 6 June 2024
Resolution: Life float waterlight battery was replaced with an approved type and expiration date of 2026.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 6 June 2024
Resolved
Each paddle must be of at least 1,220 millimeters (4 feet) in length, lashed to the life float to which they belong, and buoyant.
46 CFR 117.175(f)(2)
MI observed several life float oars were not secured to its respective life float. Each paddle was lased to its respective life float.
Action required: 10 - Deficiency Rectified
Due 6 June 2024
Resolved 6 June 2024
Resolution: MI observed unsecured life float oars were lased to its respective life float.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 6 June 2024
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers.
46 CFR 122.516(a)
MI observed 02 placards for donning life jackets were not current with the type of life jackets on board the vessel. MI observed vessel crew replace the placards.
Action required: 10 - Deficiency Rectified
Due 6 June 2024
Resolved 6 June 2024
Resolution: MI observed vessel crew members replaced outdated life jacket donning placards.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 9 November 2023
Resolved
Each vessel certified to operate on an oceans route in warm water must be provided with life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. Inspection of the life floats revealed numerous UV affected lines and pennants. Spacers between each life float were cracked and broken. All life floats shall be serviced and inspected by the Coast Guard prior to the carriage of any passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2023
Resolution: Worn UV grab lines were replaced and new spacers were placed between life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 November 2023
Resolved
Each ring buoy on a vessel must be approved in accordance with 160.050 in subchapter Q of this chapter. The port and stbd ring buoys located on the stern of the vessel have UV affected grab lines. Replace the ring buoys or the grab lines prior to the carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2023
Resolution: UV grab lines were replaced.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 April 2023
Resolved
A means of escape that is not readily apparent to a person from both inside and outside the space must be adequately marked in accordance with § 122.606 of this subchapter.
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant [name withheld] escape hatches in the engine room were not labeled, and must be labeled inside and out.
46CFR116.500(j)
46CFR122.606
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2023
Resolved 17 April 2023
Resolution: Vessel properly labeled the emergency exits from the engine room.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 9 June 2021
Resolved
A-Class bulkheads or decks must be so insulated with approved structural insulation. MI discovered missing insulation in both STBD/PORT engine room bulkheads adjacent to the waterline. Repair/replace missing insulation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2021
Resolved 16 June 2021
Resolution: Owner sent pictures showing unsat insulation replaced and satisfactorily repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 9 June 2021
Resolved
When used, flexible hose must meet the requirements of 46 CFR 56.60-25. Nonmetallic flexible hose must be in accordance with J1942. MI discovered lube oil pressure lines on both STBD/PORT generators are cotton lined and pose a fire hazard. Replace cotton lined lines.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2021
Resolved 16 June 2021
Resolution: Owner sent photos of cotton jacketed lines replaced with satisfactory uscg approved non-metallic hoses for oil service.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 June 2021
Resolved
The pendants must be as furnished by the manufacturer with the approved life float or buoant apparatus. Replacement pendants must meet the requirements in 46CFR160.010. Each pendant must be made up in a hank, and the hank secured by not more than two turns of light twine. MI discovered life float pendatns secured with line, other light twine, tied with multiple wraps preventing ability to break free.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2021
Resolved 16 June 2021
Resolution: Owner provided photos of life float pendants being secured with acceptable alternative to allow pendant hanks to readily break free.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 August 2019
Resolved
The spring in relief valve in service up to and including 250 pounds per square inch shall not be reset 10 percent below that for which the relief valve is marked. The marine inspector found that the relief valve would not reset after being manually activated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2019
Resolved 1 October 2019
Resolution: New PRV was installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 August 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to protect crew or other persons and the vessel from electrical hazards. Including fire caused by or originating in electrical equipment. In all spaces below the main deck found numerous light fixtures where the packing for cable penetrations were loose or missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2019
Resolved 1 October 2019
Resolution: Repairs have been completed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 August 2018
Resolved
U T shot under 4 engines cooling system flexible hose and send report to Marine Inspector. 46 CFR 116.300
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2018
Resolved 5 September 2018
Resolution: work list item cleared
Construction/Loadline › Hull › Weld
Issued 9 June 2017
Resolved
Grind back and make repairs to five cracked welds in port forward compartment.
Action required: 705 - Other - as specified
Due 14 June 2017
Resolved 14 June 2017
Resolution: Welds were ground back and repaired using 5356 wire.
Construction/Loadline › Structures › Deck Plating
Issued 9 June 2017
Resolved
Crop and renew wasted and holed aluminum deck plating in way of starboard and port heads (toilets) as identified. Repair proposal received.
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 24 August 2017
Resolution: Areas called out have been cropped and renewed.
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 12 April 2017
Resolved
Provide Coast Guard approved design verification test procedures.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 25 September 2018
Resolution: Performed approved tests with Hamilton jet represenative.
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 12 April 2017
Resolved
Provide Coast Guard approved periodic safety tests procedures.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 25 September 2018
Resolution: CVC no longer requires PSTPs.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 12 April 2017
Resolved
Provide carbon dioxide warning signs on both engine room entrances and entrance to CO2 storage space on each hull.
Action required: 705 - Other - as specified
Due 5 June 2017
Resolved 31 May 2017
Resolution: Posted proper signs at entrances.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 12 April 2017
Resolved
Renew emergency exit signage in jet rooms.
Action required: 705 - Other - as specified
Due 5 June 2017
Resolved 31 May 2017
Resolution: Stenciled exit signage.