KEY WEST EXPRESS

KEY WEST EXPRESS is a 2006 passenger vessel (inspected). The Coast Guard has recorded 49 inspections since 2005, most recently in October 2025, along with 60 deficiencies and 11 casualty investigations between 2007 and 2019.

Records from 2005 to 2025. Most recent: inspection, 7 October 2025.

Built
2006
Last inspected
7 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9348895 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDC9158
803446
Flag
UNITED STATES
367098340
Maury page id
psix-803446

Inspections, by type

…with no type recorded12
Years with a record 18 calendar years (2005–2025)
The 49 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)155.5 ft × 38.0 ft × 15.0 ft
Registered tonnagegross 92 / net 62
ITC dimensions (L × B × D)155.5 ft × 38.0 ft × 15.0 ft
ITC tonnagegross 791 / net 266
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 2006
Hull materialAluminum
PropulsionJet Drive
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portKEY WEST, FL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 21 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it92 - Regulatory (Subpart C or D), Gross Ton
791 - Convention (Subpart B), Gross Ton
62 - Regulatory (Subpart C or D), Net Ton
266 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC9158MMSI 367098340 · active · compulsorily equipped · granted 11 February 2026, expires 10 March 2036
EX281MMSI 367098340 · expired · exemption · granted 8 October 2020, cancelled 12 October 2024
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BIG CAT EXPRESS Passenger (Inspected) · MISLE 662399 · 27 December 2016 · activity 6069512

Inspection history · 49

7 October 2025 COI Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8238936
25 April 2025 Type not recorded
No type recorded · Station Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8121205
3 December 2024 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8039552
5 September 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7959752
28 November 2023 Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7830109
29 November 2022 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7600484
14 October 2022 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7577237
21 September 2022 Deficiency Check · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7524049
30 November 2021 MTSA Verification · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7358710
15 April 2021 In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7178345
17 November 2020 Administrative Inspection · COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7092746
29 June 2020 Plan Review (Other than "T") · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6953488
27 June 2020 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6991259
3 December 2019 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6863592
29 May 2019 Administrative Inspection · Examination of Repairs · Damage Survey · Deficiency Check · Welding Related Inspections Qualification Testing
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6698320
25 April 2019 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6670359
1 March 2019 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6635036
10 January 2019 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6624682
30 October 2018 Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6568738
6 September 2018 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6489062
15 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6512886
13 June 2018 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6490407
5 December 2017 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6314783
25 September 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6274381
18 August 2017 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6244544
7 June 2017 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6168339
27 December 2016 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6069512
29 November 2016 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6043592
8 December 2015 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5768492
18 November 2015 Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5766186
5 October 2015 Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5758172
22 January 2012 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4231533
9 January 2012 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4230691
13 December 2011 Deficiency Check · MTSA Verification · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4206801
24 August 2011 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4125741
20 January 2011 Deficiency Check · COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3924169
9 September 2010 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3846751
24 February 2010 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3688477
12 December 2008 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3379061
4 June 2008 Annual Inspection · MTSA Verification
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3207043
20 May 2008 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3211569
6 September 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3049966
25 June 2007 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2973074
2 April 2007 In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2901327
1 March 2007 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3022401
2 June 2006 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2668512
20 April 2006 In-Service Inspection · MTSA Verification · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2627435
2 February 2006 Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2577892
27 January 2005 Initial Construction-Excluding Oversight · COI Inspection · Initial Certification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2580619

Deficiency record · 60

09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 October 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Li-ion batteries and devices should be securely stored in a dry and cool location away from combustible material. MI observed Li-ion batteries, chargers, and associated equipment stored in the PORT AFT vestibule, a heated space. Relocate batteries to a cool, dry space. 46 CFR 115.830 (a) CG-CVC Policy Letter 20-03
Action required: 10 - Deficiency Rectified
Due 7 October 2025
Resolved 7 October 2025
Resolution: Batteries removed to cool, dry space.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 7 October 2025 Resolved
Fire dampers must be capable of manual operation from outside the space served. MI observed STBD AFT fire damper stuck in closed position when remote switch returned to OPEN. Make repair to the satisfaction of the attending Coast Guard MI. 46 CFR 116.610 (g) (4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2025
Resolved 9 October 2025
Resolution: STBD AFT fire damper no longer stuck in closed position when remote switch returned to OPEN, and is operating as designed.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 7 October 2025 Resolved
The owner, charterer, master, or managing operator shall instruct each crew member as to the duties that the crew member is expected to perform in an emergency. MI observed crewmembers unfamiliar with emergency engine fuel shutoff valve reset procedures leading to inadvertent shutdown of ship service generators while underway. Conduct all hands training on proper valve reset procedures within 14 days. 46 CFR 122.420 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2025
Resolved 9 October 2025
Resolution: Conducted all hands training on proper valve reset procedures and updated training check sheets.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 October 2025 Resolved
Except as otherwise provided in this section, each space accessible to passengers or used by the crew on a regular basis, must have at least two means of escape, one of which must not be a watertight door. MI observed interior door handle to the PORT side engine room entrance disconnected and preventing engine room egress. Repair door handle and prove proper operation to the attending Coast Guard MI. 46 CFR 116.500 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2025
Resolved 9 October 2025
Resolution: Repaired door handle and proved proper operation.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 October 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the inspection and operation of all watertight closures in the hull, decks, and bulkheads including through hull fittings and sea valves. MI observed through hull fitting located in deck of PORT side jet room missing a handle and preventing proper operation. Make permanent repair to through hull fitting to the satisfaction of the attending Coast Guard MI. 46 CFR 115.802 (a) (2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2025
Resolved 9 October 2025
Resolution: Installed handle on hull fitting located in deck of PORT side jet room.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 3 December 2024 Resolved
A fire damper and casing must be at least 11USSG and not more than 0.125 inch gap between the blade and casing. 01 fire damper servicing starboard E/R and 02 servicing the port E/R are not fully closing and leaving a gap exceeding 0.125 inch. 46 CFR 116.610(g)(1)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 December 2024
Resolution: Dampers were exercised (open/closed) and no longer "sticking" and now fully closing.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 December 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. MI observed section of non-skid on second deck that is peeling back and creating a tripping hazard for passengers and crew members. 46 CFR 115.830(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2024
Resolved 4 December 2024
Resolution: Non-skid was secured to the deck and no longer a tripping hazard.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 3 December 2024 Resolved
Each paddle must be of at least 4 feet in length, lasted to the life float to which they belong and buoyant. 02 paddles on one set of life floats on starboard side and 01 paddle on another set on the forward port side are not lashed to the life float. 46 CFR 117.175(f)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2024
Resolved 4 December 2024
Resolution: Life float paddles were properly lashed to their respective life float.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 December 2024 Resolved
A vessel on a limited coastwise route must carry six hand red flare distress signals and six hand orange smoke distress signals. Six orange smoke distress signals were expired. 46 CFR 117.68(a)(2)
Action required: 10 - Deficiency Rectified
Resolved 3 December 2024
Resolution: Six expired orange smoke distress signals were put replaced with new valid ones.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 3 December 2024 Resolved
Each life float must be fitted with a lifeline, pendants, a painter, and a light. 01 life float had a inoperable light. 46 CFR 117.175(e)
Action required: 10 - Deficiency Rectified
Resolved 3 December 2024
Resolution: Life float light was replaced with a working light.
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 28 November 2023 Resolved
The intended primary rescue platform locations, port and starboard, must be readily visible from the vessel's control position. The rescue platform and adjacent area where the recovery of a person in the water is conducted is unable to adequately observe from the operation station. Submit a proposal to the Coast Guard to make the primary platform locations, port and starboard, readily visible from the vessel's control position. 46 CFR 180.210(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 December 2023
Resolved 30 November 2023
Resolution: The vessel installed an additional camera to the existing closed circuit monitoring system to make the rescue platform and adjacent area readily visible from the vessel's control position. The vessel installed an additional camera to the existing CCTV.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 22 September 2022 Resolved
Identified two self tapping screws coming through the inboard side shell located in the starboard hull jet room. Provide plan proposal for repairs.
Action required: 705 - Other - as specified
Due 22 September 2022
Resolved 6 October 2022
Resolution: New 18"x 18" plate was inserted, inspected back gouge and vacuum box test.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 21 September 2022 Resolved
A hatch exposed to the weather must be watertight. Identified forward center line anchor line hatch that had been leaking due to gasket. 46 CFR 179.360(a)
Action required: 705 - Other - as specified
Due 21 September 2022
Resolved 24 October 2022
Resolution: Rcvd email with new replacement gasket installed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 30 November 2021 Resolved
Each vessel certificated to operate on an oceans route in warm water must be provided with life floats that will accommodate at least 100% of the total number of persons onboard. 25 person life float in the middle of the starboard forward stack is condemned due to excessive deterioration and shrinkage of insulation. Total person capacity reduced to 500 until a new life float is properly installed to the satisfaction of a Marine Inspector. 46 CFR 117.200(c) table
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 2 December 2021
Resolution: Received photos of newly installed 22 person life float. Amended vessel details to reflect total lifesaving capacity of 522. COI allows 520 persons onboard.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 17 November 2020 Resolved
Vessel does not have MF radio installation. FCC issued an exemption for transit up to 50 miles offshore due to sat-phone installation. Vessel limited to 50 miles offshore.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2020
Resolved 24 November 2020
Resolution: Received updated FCC exemption with 100 mile stipulation.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 17 November 2020 Resolved
A-60 fire boundary in port engine room IWO the generator adjacent to underwing compartment is compromised via stuffing box not properly insulated.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2020
Resolved 24 November 2020
Resolution: Verified properly insulated electrical run in bulkhead.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 November 2020 Resolved
Electrical wiring in both engine rooms for newly installed M/E controls is connected to previous cable runs with zip ties. Properly secure new cables with metal fasteners.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2020
Resolved 24 November 2020
Resolution: Verified properly secured electrial runs.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 August 2018 Resolved
Vsl is broadcasting: No IMO # and not broadcasting an AIS Ship Type.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 September 2018
Resolved 9 October 2018
Resolution: AIS deficiency corrected
Fire Fighting › Fire Pumps › Pressure
Issued 5 December 2017 Resolved
FCire pump gauge is not displaying pressure, repair/replace. (46CFR181.300)
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 19 December 2017
Resolution: Replaced gauge.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 5 December 2017 Resolved
Replace signage for CO2 in engine room and space containing CO2 from 46CFR185.612(g)(1)(2)
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 19 December 2017
Resolution: Proper signage posted on both areas.
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 29 November 2016 Resolved
Provide Coast Guard approved design verification test procedures
Action required: 705 - Other - as specified
Due 29 December 2016
Resolved 13 June 2018
Resolution: Completed required msc approved tests.
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 29 November 2016 Resolved
Provide Coast Guard approved periodic safety tests
Action required: 705 - Other - as specified
Due 29 December 2016
Resolved 13 June 2018
Resolution: completed required MSC approved tests.
Lifesaving › Lifefloat › Pendant
Issued 29 November 2016 Resolved
Two straps for lifefloat pendant are broken
Action required: 705 - Other - as specified
Due 13 December 2016
Resolved 1 December 2016
Resolution: Straps replaced.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 November 2016 Resolved
Line on two aft life rings is frayed and worn.
Action required: 705 - Other - as specified
Due 13 December 2016
Resolved 1 December 2016
Resolution: Lines replaced.
Lifesaving › Lifefloat › Lifeline
Issued 8 December 2015 Resolved
As per 46CFR117.202, vessel is required to have serviceable grab lines on all lifefloats. 02 lifefloats have wasted grab lines. Vessel's passenger count reduced by 50 to a max passenger count of 461.
Action required: 705 - Other - as specified
Resolved 9 December 2015
Resolution: Replaced wasted grab lines.
Electrical › Electric Supply System (service) › Cable
Issued 8 December 2015 Resolved
As per 46CFR120.350(d), vessel's batteries must have permanent type connectors.
Due 15 December 2015
Resolved 9 December 2015
Resolution: Permanent type connector installed on all batteries.
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 December 2015 Resolved
As per 46CFR115.830, vessel's batteries must have caps installed to prevent spillage. "Good marine practice"
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2015
Resolution: Caps were installed on all batteries.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 8 December 2015 Resolved
As per 46CFR115.830 (Good marine practice), vessel must remove all trash in engine room bilges.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2015
Resolution: All trash in Engine Room bilge has been removed.
Engineering › Fuel Oil Service System › Piping
Issued 8 December 2015 Resolved
As per 46CFR119.445(b), vessel's port fwd engine's fuel leak must be repaired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2015
Resolution: Repaired fuel leak.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 December 2015 Resolved
As per 46CFR111.60-13, ensure both port and stbd fans in engine rooms be hard wired or removed.
Due 15 December 2015
Resolved 8 December 2015
Resolution: Fans hard wired.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 December 2015 Resolved
As per 46CFR120.200(a), repair faulty globe light and fluorescent lights in stbd jet room.
Due 15 December 2015
Resolved 9 December 2015
Resolution: Repaired faulty lighting.
Stability › Watertight Integrity › General
Issued 8 December 2015 Resolved
As per 46CFR116.1160, replace gasket on port side jet room hatch.
Due 15 December 2015
Resolved 9 December 2015
Resolution: Gasket replaced on port side jet room hatch.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 8 December 2015 Resolved
As per 46CFR120.432, repair emergency lighting port, aft passageway.
Due 15 December 2015
Resolved 9 December 2015
Resolution: Emergency light repaired.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 8 December 2015 Resolved
As per 46CFR120.200, replace missing breaker in breaker panel on bridge, or install a blank.
Due 15 December 2015
Resolved 9 December 2015
Resolution: Blank was installed where breaker was missing.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 8 December 2015 Resolved
As per 46CFR122.604(b), ensure all lifejackets are stenciled with vessel's name on both sides.
Due 15 December 2015
Resolved 9 December 2015
Resolution: Lifejackets properly marked on both sides.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 8 December 2015 Resolved
As per 46CFR117.75(a), ensure all lifejackets have lights.
Due 15 December 2015
Resolved 9 December 2015
Resolution: All lifejackets have lights.
Construction/Loadline › Hull › Bottom Plating
Issued 18 November 2015 Resolved
Submit Repair Proposal for the replacement/repairs to the MDE & SSDG sea suction scoops IAW 46 CFR 115.610.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 25 November 2015
Resolved 24 November 2015
Engineering › Sea-water System (primary cooling) › Valve
Issued 18 November 2015 Resolved
Demonstrate proper operation of the following sea valves: (2) SSDG sea water suction, (1) Port side Bilge suction, and (1) Stbd side firemain suction, IAW 46 CFR 115.610.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 November 2015
Resolved 24 November 2015
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 18 November 2015 Resolved
Properly repair (4) cracked welds, located in #2 stbd void. IAW 46 CGR 115.610
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 November 2015
Resolved 24 November 2015
Deck/Cargo › Holds/Tanks › Hatch
Issued 18 November 2015 Resolved
Properly replace all gaskets to machinery space hatches. IAW 46 CFR 171.124
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 November 2015
Resolved 24 November 2015
Engineering › Lubricating Oil Service System › Filter
Issued 13 December 2011 Resolved
Secure oil leak at stbd side oil filter on main (aft) IAW 46 CFR 115.830.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2011
Engineering › Sea-water System (primary cooling) › Piping
Issued 13 December 2011 Resolved
Secure coolant leak at vent tube on stbd side fwd main IAW 115.830.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2011
Lifesaving › Lifefloat › Painter
Issued 13 December 2011 Resolved
Secure life light painters around the body of all life floats onboard painters found not secured around life floats IAW 46 CFR 117.137(d)(1).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2011
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 January 2011 Resolved
Provide first aid kit on board IAW 46CFR121.710. Kit on board missing several required items. New kit shall be on board no later than 03FEB11.
Action required: 705 - Other - as specified
Due 3 February 2011
Resolved 1 February 2011
Resolution: Provided First Aid Kit
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 20 January 2011 Resolved
Remove portable oven from bar area. Oven in bar area does not have suitable fire protection for an oven and does not meet the requirements of 46CFR116.415 High Risk Service Space. Remove prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 January 2011
Fire Fighting › Remote Fuel Shutoff › General
Issued 20 January 2011 Resolved
Adjust fuel oil shut off valves so they close completely IAW 46CFR119.455(b)(3) prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 January 2011
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 20 January 2011 Resolved
Revise the vessel's oil transfer procedures IAW 33CFR155.750 by 21FEB11.
Action required: 705 - Other - as specified
Due 21 February 2011
Resolved 15 February 2011
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 20 January 2011 Resolved
Repair main deck hatches so that they are completely secured IAW 46CFR115.830 by 03FEB11.
Action required: 705 - Other - as specified
Due 3 February 2011
Resolved 21 January 2011
Engineering › Steering Gear System › Motor
Issued 25 June 2007 Resolved
REPAIR OUTBOARD #4 STEERING SYSTEM TO BE OPERABLE IN ALL LOCATIONS AND PROVE PROPER OPERATION.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2007
Engineering › Bilge Water Management System › Not Operational
Issued 25 June 2007 Resolved
PROVE PROPER OPERATION OF THE BILGE SYSTEM.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2007
Resolution: CLEARED
Engineering › Fuel Oil Service System › Valve, Control
Issued 25 June 2007 Resolved
PROVE PROPER OPERATION OF THE FUEL SHUT OFF SYSTEM.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2007
Resolution: CLEARED
Electrical › Lighting (service) › Lighting Fixture
Issued 25 June 2007 Resolved
REPLACE LIGHTS IN VOID #2 (FUEL OIL COMPARTMENT).
Action required: 705 - Other - as specified
Resolved 26 June 2007
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 25 June 2007 Resolved
REPLACE RETRO REFLECTIVE TAPE STBD AFT RINGBUOY AND RE-STENCIL PORT AFT. ADDITIONALLY, PROVIDE NON CORROSIVE CLIP FOR WATERLIGHT.
Action required: 705 - Other - as specified
Resolved 26 June 2007
Operations/Management › Vessel Safety Management › Designated Person(s)
Issued 25 June 2007 Resolved
PROVE COMPLIANCE WITH [name withheld] FOR DEVELOPING CREW TRAINING PROGRAM FOR ENGINEERS.
Action required: 705 - Other - as specified
Due 31 July 2007
Resolved 15 August 2007
Lifesaving › Lifefloat › Float Free
Issued 2 April 2007 Resolved
Remove line securing lifefloats to deck , lifefloat would not float free.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2007
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 20 April 2006 Resolved
Provide a copy of the company's operations and training manuals to the cognizant OCMI for approval. Provide draft N.L.T. 20MAY2006.
Action required: 705 - Other - as specified
Due 20 May 2006
Resolved 26 May 2006
Resolution: Rcvd a copy of both plans via mail
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 20 April 2006 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 21 April 2006
Operations/Management › Passenger Operations › Safety Orientation
Issued 20 April 2006 Resolved
Provide maximun passenger capacity signage for upper most passenger deck. The upper deck is limited/restricted to a maximun of 124 passengers as per the certificate of Inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2006
Resolved 21 April 2006
Documentation › Logs/Records › Logbook (official)
Issued 20 April 2006 Resolved
Provide evidence/proof of an official logbook to include emergency drills preformed by the vessels crew. Log book should include all drills preformed in the presence of a CG marine inspector.
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 21 April 2006
Personnel › Training › Familiarization Training
Issued 27 January 2005 Resolved
Crew shall conduct drills with local Coast Guard marine inspectors in Ft. Myers Florida prior to operation for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2006

Casualty record · 11

1 March 2007Routine · role: Involved in a Marine Casualty · activity 3022401
12 December 2008Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 3379061
2 March 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3960453
8 June 2011Routine · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · 1 injured · activity 4039165
13 November 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4188291
9 January 2012Routine · role: Involved in a Marine Casualty · 1 injured · activity 4230691
22 January 2012Routine · role: Involved in a Marine Casualty · 1 injured · activity 4231533
20 June 2013Routine · role: Involved in a Marine Casualty · activity 4626107
27 December 2016Routine · role: Transiting Vicinity of Primary Subject · activity 6069512
18 August 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6244544
10 January 2019Routine · role: Involved in a Marine Casualty · 1 injured · activity 6624682
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.