Records from 2007 to 2025. Most recent: inspection, 7 October 2025.
Inspection history · 28
7 October 2025
COI Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8238936
25 April 2025
Type not recorded
No type recorded · Station Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8121205
3 December 2024
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8039552
5 September 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7959752
28 November 2023
Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7830109
29 November 2022
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7600484
14 October 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7577237
21 September 2022
Deficiency Check · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7524049
30 November 2021
MTSA Verification · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7358710
15 April 2021
In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7178345
17 November 2020
Administrative Inspection · COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7092746
29 June 2020
Plan Review (Other than "T") · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6953488
27 June 2020
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6991259
3 December 2019
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6863592
29 May 2019
Administrative Inspection · Examination of Repairs · Damage Survey · Deficiency Check · Welding Related Inspections Qualification Testing
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6698320
25 April 2019
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6670359
1 March 2019
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6635036
10 January 2019
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6624682
30 October 2018
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6568738
6 September 2018
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6489062
15 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6512886
13 June 2018
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6490407
5 December 2017
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6314783
25 September 2017
Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6274381
18 August 2017
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6244544
7 June 2017
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6168339
27 December 2016
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6069512
29 November 2016
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6043592
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 October 2025
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Li-ion batteries and devices should be securely stored in a dry and cool location away from combustible material. MI observed Li-ion batteries, chargers, and associated equipment stored in the PORT AFT vestibule, a heated space. Relocate batteries to a cool, dry space.
46 CFR 115.830 (a)
CG-CVC Policy Letter 20-03
Action required: 10 - Deficiency Rectified
Due 7 October 2025
Resolved 7 October 2025
Resolution: Batteries removed to cool, dry space.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 7 October 2025
Resolved
Fire dampers must be capable of manual operation from outside the space served. MI observed STBD AFT fire damper stuck in closed position when remote switch returned to OPEN. Make repair to the satisfaction of the attending Coast Guard MI.
46 CFR 116.610 (g) (4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2025
Resolved 9 October 2025
Resolution: STBD AFT fire damper no longer stuck in closed position when remote switch returned to OPEN, and is operating as designed.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 7 October 2025
Resolved
The owner, charterer, master, or managing operator shall instruct each crew member as to the duties that the crew member is expected to perform in an emergency. MI observed crewmembers unfamiliar with emergency engine fuel shutoff valve reset procedures leading to inadvertent shutdown of ship service generators while underway. Conduct all hands training on proper valve reset procedures within 14 days.
46 CFR 122.420 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2025
Resolved 9 October 2025
Resolution: Conducted all hands training on proper valve reset procedures and updated training check sheets.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 October 2025
Resolved
Except as otherwise provided in this section, each space accessible to passengers or used by the crew on a regular basis, must have at least two means of escape, one of which must not be a watertight door. MI observed interior door handle to the PORT side engine room entrance disconnected and preventing engine room egress. Repair door handle and prove proper operation to the attending Coast Guard MI.
46 CFR 116.500 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2025
Resolved 9 October 2025
Resolution: Repaired door handle and proved proper operation.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 October 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the inspection and operation of all watertight closures in the hull, decks, and bulkheads including through hull fittings and sea valves. MI observed through hull fitting located in deck of PORT side jet room missing a handle and preventing proper operation. Make permanent repair to through hull fitting to the satisfaction of the attending Coast Guard MI.
46 CFR 115.802 (a) (2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2025
Resolved 9 October 2025
Resolution: Installed handle on hull fitting located in deck of PORT side jet room.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 3 December 2024
Resolved
A fire damper and casing must be at least 11USSG and not more than 0.125 inch gap between the blade and casing. 01 fire damper servicing starboard E/R and 02 servicing the port E/R are not fully closing and leaving a gap exceeding 0.125 inch.
46 CFR 116.610(g)(1)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 December 2024
Resolution: Dampers were exercised (open/closed) and no longer "sticking" and now fully closing.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 December 2024
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. MI observed section of non-skid on second deck that is peeling back and creating a tripping hazard for passengers and crew members.
46 CFR 115.830(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2024
Resolved 4 December 2024
Resolution: Non-skid was secured to the deck and no longer a tripping hazard.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 3 December 2024
Resolved
Each paddle must be of at least 4 feet in length, lasted to the life float to which they belong and buoyant. 02 paddles on one set of life floats on starboard side and 01 paddle on another set on the forward port side are not lashed to the life float.
46 CFR 117.175(f)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2024
Resolved 4 December 2024
Resolution: Life float paddles were properly lashed to their respective life float.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 December 2024
Resolved
A vessel on a limited coastwise route must carry six hand red flare distress signals and six hand orange smoke distress signals. Six orange smoke distress signals were expired.
46 CFR 117.68(a)(2)
Action required: 10 - Deficiency Rectified
Resolved 3 December 2024
Resolution: Six expired orange smoke distress signals were put replaced with new valid ones.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 3 December 2024
Resolved
Each life float must be fitted with a lifeline, pendants, a painter, and a light. 01 life float had a inoperable light.
46 CFR 117.175(e)
Action required: 10 - Deficiency Rectified
Resolved 3 December 2024
Resolution: Life float light was replaced with a working light.
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 28 November 2023
Resolved
The intended primary rescue platform locations, port and starboard, must be readily visible from the vessel's control position.
The rescue platform and adjacent area where the recovery of a person in the water is conducted is unable to adequately observe from the operation station.
Submit a proposal to the Coast Guard to make the primary platform locations, port and starboard, readily visible from the vessel's control position.
46 CFR 180.210(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 December 2023
Resolved 30 November 2023
Resolution: The vessel installed an additional camera to the existing closed circuit monitoring system to make the rescue platform and adjacent area readily visible from the vessel's control position. The vessel installed an additional camera to the existing CCTV.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 22 September 2022
Resolved
Identified two self tapping screws coming through the inboard side shell located in the starboard hull jet room.
Provide plan proposal for repairs.
Action required: 705 - Other - as specified
Due 22 September 2022
Resolved 6 October 2022
Resolution: New 18"x 18" plate was inserted, inspected back gouge and vacuum box test.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 21 September 2022
Resolved
A hatch exposed to the weather must be watertight.
Identified forward center line anchor line hatch that had been leaking due to gasket.
46 CFR 179.360(a)
Action required: 705 - Other - as specified
Due 21 September 2022
Resolved 24 October 2022
Resolution: Rcvd email with new replacement gasket installed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 30 November 2021
Resolved
Each vessel certificated to operate on an oceans route in warm water must be provided with life floats that will accommodate at least 100% of the total number of persons onboard.
25 person life float in the middle of the starboard forward stack is condemned due to excessive deterioration and shrinkage of insulation.
Total person capacity reduced to 500 until a new life float is properly installed to the satisfaction of a Marine Inspector.
46 CFR 117.200(c) table
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2021
Resolved 2 December 2021
Resolution: Received photos of newly installed 22 person life float. Amended vessel details to reflect total lifesaving capacity of 522. COI allows 520 persons onboard.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 17 November 2020
Resolved
Vessel does not have MF radio installation. FCC issued an exemption for transit up to 50 miles offshore due to sat-phone installation. Vessel limited to 50 miles offshore.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2020
Resolved 24 November 2020
Resolution: Received updated FCC exemption with 100 mile stipulation.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 17 November 2020
Resolved
A-60 fire boundary in port engine room IWO the generator adjacent to underwing compartment is compromised via stuffing box not properly insulated.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2020
Resolved 24 November 2020
Resolution: Verified properly insulated electrical run in bulkhead.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 November 2020
Resolved
Electrical wiring in both engine rooms for newly installed M/E controls is connected to previous cable runs with zip ties. Properly secure new cables with metal fasteners.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2020
Resolved 24 November 2020
Resolution: Verified properly secured electrial runs.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 August 2018
Resolved
Vsl is broadcasting: No IMO # and not broadcasting an AIS Ship Type.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 September 2018
Resolved 9 October 2018
Resolution: AIS deficiency corrected
Fire Fighting › Fire Pumps › Pressure
Issued 5 December 2017
Resolved
FCire pump gauge is not displaying pressure, repair/replace. (46CFR181.300)
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 19 December 2017
Resolution: Replaced gauge.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 5 December 2017
Resolved
Replace signage for CO2 in engine room and space containing CO2 from 46CFR185.612(g)(1)(2)
Action required: 705 - Other - as specified
Due 19 December 2017
Resolved 19 December 2017
Resolution: Proper signage posted on both areas.
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 29 November 2016
Resolved
Provide Coast Guard approved design verification test procedures
Action required: 705 - Other - as specified
Due 29 December 2016
Resolved 13 June 2018
Resolution: Completed required msc approved tests.
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 29 November 2016
Resolved
Provide Coast Guard approved periodic safety tests
Action required: 705 - Other - as specified
Due 29 December 2016
Resolved 13 June 2018
Resolution: completed required MSC approved tests.
Lifesaving › Lifefloat › Pendant
Issued 29 November 2016
Resolved
Two straps for lifefloat pendant are broken
Action required: 705 - Other - as specified
Due 13 December 2016
Resolved 1 December 2016
Resolution: Straps replaced.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 November 2016
Resolved
Line on two aft life rings is frayed and worn.
Action required: 705 - Other - as specified
Due 13 December 2016
Resolved 1 December 2016
Resolution: Lines replaced.