Records from 2004 to 2026. Most recent: inspection, 10 March 2026.
Documentation record
Registered dimensions (L × B × D)76.7 ft × 28.0 ft × 11.0 ft
Registered tonnagegross 94 / net 64
ITC dimensions (L × B × D)76.7 ft × 28.0 ft × 11.0 ft
ITC tonnageNot recorded
BuilderRODRIGUEZ BOAT BUILDER INC · CODEN, AL, UNITED STATES · built 2003
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it94 - Regulatory (Subpart C or D), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 25
10 March 2026
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8324162
17 December 2025
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8284654
28 August 2024
COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7991489
13 December 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7831450
17 February 2023
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7638055
17 January 2023
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7625716
23 November 2021
Drydock Exam · Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7356465
15 November 2021
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7351593
14 November 2021
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7637951
23 November 2020
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7100737
13 November 2019
Initial Certification · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6859063
27 August 2015
Industry Initiated Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5231045
22 January 2015
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5057154
13 June 2014
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4887700
16 March 2014
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4821811
14 March 2014
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4816058
10 March 2014
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4815308
1 March 2014
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4822071
8 May 2013
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4768075
1 May 2013
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4580931
10 February 2010
Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3678598
29 October 2009
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3624020
2 August 2006
MTSA Verification · Uninspected Other
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2734104
8 September 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2190309
3 June 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2087326
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 February 2023
Resolved
Vessel hit stbd side of during operations against the stern of another vessel. Rail cap was damaged. Ensure all other structural members are sound and watertight integrity is not compromised.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 April 2023
Resolution: Received picture of fixed rail cap.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 15 November 2021
Resolved
An approved 160-B semi-portable fire-extinguishing system to protect the engine room. Semi-portable was unable to protect the engine room due to it being in the engine room.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 December 2021
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 November 2021
Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Bilge has excess amount of oily water.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 November 2021
Resolution: Bilges were cleaned of excess oily water.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 November 2021
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Lagging on stbd main was soaked in oil and degreaser.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 December 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 November 2021
Resolved
The valve must be operable from a safe place outside the space where the valve is installed. The fuel shut off valve did not work for the stbd main.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 December 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 November 2021
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. Sight glasses on fuel tanks were melted.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2021
Resolution: Sight glasses were replaced.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 November 2020
Resolved
Individuals who are not crew members, on board a towing vessel must receive a safety orientation prior to getting underway or as soon as practicable thereafter. Vessel did not provide orientation.
46 CFR 140.415
Action required: 10 - Deficiency Rectified
Due 23 November 2020
Resolved 23 November 2020
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 November 2020
Resolved
Owner or managing operator must implement a health and safety plan. Plan must document compliance with this part and include record keeping procedures. Crew training and annual refresher not recorded.
46 CFR 140.500(a)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2020
Resolved 1 December 2020
Resolution: Training provided to crew and recorded.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 23 November 2020
Resolved
Before vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Vessel's hydrostatic release and painter line on raft were installed improperly.
46 CFR 199.190(a)
Action required: 10 - Deficiency Rectified
Due 23 November 2020
Resolved 23 November 2020
Resolution: Corrected on the spot; unit installed correctly
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 November 2020
Resolved
Records of drills and instructions must be maintained in the TVR or official logbook to include the date of the drill and instruction, a description of the drill scenario and instruction topics and the personnel involved. Vessel did not describe in detail the drills conducted.
46 CFR 140.420(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2020
Resolved 1 December 2020
Resolution: Drill records provided with included details.