MISS COLETTE II

MISS COLETTE II is a 2003 tank barge. The Coast Guard has recorded 29 inspections since 2002, most recently in April 2026, along with 14 deficiencies and 1 casualty investigation in 2018.

Records from 2002 to 2026. Most recent: inspection, 27 April 2026.

Built
2003
Last inspected
27 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 27 April 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 21 calendar years (2002–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDB4756
663298
Flag
UNITED STATES
Maury page id
psix-663298

Documentation record

Registered dimensions (L × B × D)100.0 ft × 30.0 ft × 7.0 ft
Registered tonnagegross 176 / net 176
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCONRAD SHIPYARD LLC · MORGAN CITY, LA, UNITED STATES · built 2003
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portHOUMA, LA
Trade endorsementsRegistry, non-fishing vessel
DocumentationValid · issued 6 May 2026 · expires 30 June 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it176 - Simplified, Gross Ton
176 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAPT. JIM Towing Vessel · MISLE 475091 · 3 November 2018 · activity 6576405MARY ANNE MC Towing Vessel · MISLE 69156 · 16 April 2002 · activity 1611909

Inspection history · 29

27 April 2026 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8356477
20 May 2025 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8140147
15 May 2024 Drydock Exam · COI Inspection · Internal Structural Exam · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7912340
3 August 2023 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7759374
6 July 2022 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7498392
16 June 2021 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7226723
24 June 2020 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6985384
7 May 2019 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6678562
29 April 2019 Drydock Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6672387
3 November 2018 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6576405
3 November 2018 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6596626
5 June 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6434572
5 April 2017 Administrative Inspection · Inclining Experiment · Periodic Inspection · Deadweight Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6118621
13 April 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5853106
3 March 2016 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5826566
4 February 2015 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5063282
7 January 2015 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5048670
14 April 2014 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4833860
8 April 2014 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4831197
7 August 2012 Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4402649
4 June 2010 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3756926
25 February 2009 COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3423676
13 June 2007 Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2960773
11 April 2007 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2905806
30 March 2006 Re-Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2612954
15 April 2005 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2347286
22 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1973361
8 December 2003 Construction Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1960685
16 April 2002 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1611909

Deficiency record · 14

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 August 2023 Resolved
Thermal fluid heaters are examined by a marine inspector to determine that the complete unit is in a safe and satisfactory condition. Upon crew member voluntarily starting the thermal fluid heater, an exhaust gas leak was noticed on the bottom outer shell pipe connecting to the bottom of the thermal fluid tank. 46 CFR 61.30-15
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2023
Resolution: Verified operation of TFH and received the repair and hydrostatic testing from Third Party.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 August 2023 Resolved
The type, size, location and arrangement of portable and semiportable extinguishers shall be as set forth in subpart 34.50. Vessel only had 06 fire extinguishers when required 07. 46 CFR 34.05-10
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2023
Resolution: Vessel added Fire Extinguisher per Fire Plan.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 August 2023 Resolved
All safety and relief valves for use on pressure vessels or piping systems shall be designed to meet the protection and service requirements for which they are intended and shall be set to relieve at a pressure which does not exceed the maximum allowable working pressure of the pressure vessel. Pressure vessel relief valve was set at 180 psi while pressure vessel maximum allowable working pressure was set at 175 psi. 46 CFR 54.15-10(a)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 August 2023
Resolution: Received photo evidence of correct pressure relief valve installation with data tag installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 August 2023 Resolved
Each lifebuoy must be marked with the name of the vessel. Name on the FWD life buoy did not have the correct name as the COI. 46 CFR 199.70(2)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2023
Resolution: Lifebuoy is properly marked and installed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 August 2023 Resolved
Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Vessel could not produce a record of monthly inspection for their installed fire extinguishers. 46 CFR 31.10-18(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 August 2023
Resolution: Educated Master and Vessel rep on requriments.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 August 2023 Resolved
Each lifesaving appliance must be inspected monthly. Vessel could not produce a record of monthly inspection of lifesaving appliances. 46 CFR 199.190(e)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 August 2023
Resolution: Vessel Rep and Master educated on requirements.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 June 2021 Resolved
"Each vessel must carry lifebuoys approved under approval series 160.150" Ring buoy was full of water. Needs replacement. 46 CFR 199.70
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 16 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 June 2021 Resolved
"Where pressure-indicating gauges are used, they shall be chosen to be compatible with the pressure to be indicated.The size of the visual display, the fineness of graduations, and the orientation of the display will be considered. In no case shall the upper range of the gauge be less than 1.2 times nor more than 2 times the pressure at which the relieving device is set to function." Gauge was not able to read 1.2 times the setting of the relief device. Replace with gauge that reads 1.2-2 times the pressure of the relief device. 46 CFR 54.15-5(f)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 16 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 June 2020 Resolved
Operational tests and checks of all safety and limit controls, combustion controls, programming controls, and safety relief valves must be conducted at the inspection for certification, periodic inspection, and when directed by the OCMI; Thermal fluid heater was unable to run through series of shutdown tests and alarms; Provide proof of operation of Thermal fluid heater shutdown tests and alarms prior to operation; To the satisfaction of the OCMI.
Action required: 66 - Prior to drilling or production operations
Due 8 July 2020
Resolved 30 June 2020
Resolution: Attended vessel afloat and witnessed successful operation of all thermal fluid heater shutdowns and alarms.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 May 2019 Resolved
Non-Metallic F/O lines are required to comply with fire safety standards. VSL's thermal fluid heater and cargo pump prime mover F/O hoses are cotton jacketed. Documentation for said F/O lines were not available for inspection. VSL must provide Non-Metallic F/O lines which comply with applicable fire safety regulations.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 May 2019
Resolution: VSL replaced Non Metallic F/O lines with approved flex hoses.
Stability › Intact Stability (when using lifting gear) › General
Issued 5 April 2017 Resolved
Prove compliance with stability requirements in 46 CFR Subchapter S
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 21 July 2017
Resolution: approved stability letter issued, stability requirements of Subchapter S, met.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 14 April 2014 Resolved
Vessel's crane is due for its 60 month test IAW 46 CFR 107.258-260. Previous test was not done with the proper weights. Crane must remain out of service until a test IAW API standards and CFR is conducted in the presence of an attending CG Marine Inspector.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 7 January 2015
Resolution: MI attended vessel and witnessed 60 month crane weight tests IAW 107.260. All sat.
Personnel › Training › Familiarization Training
Issued 13 June 2007 Resolved
Train Person in Charge to conduct thermal fluid heater tests.
Due 30 June 2007
Resolved 25 June 2007
Resolution: Provided letter documenting training of employee.
Stability › Intact Stability (when using lifting gear) › General
Issued 13 June 2007 Resolved
Provide crane stability verification.
Due 31 July 2007
Resolved 20 July 2007
Resolution: Provided documentation.

Casualty record · 1

3 November 2018Routine · role: Involved in a Marine Casualty · activity 6576405
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

MISS COLLETTE II (2018). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.