Records from 1997 to 2026. Most recent: inspection, 4 June 2026.
Inspection history · 21
4 June 2026
Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8390707
27 May 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8145245
4 March 2024
COI Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7873772
15 February 2024
Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7866261
14 October 2022
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7577016
2 August 2021
Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 7275275
13 July 2021
COI Inspection · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7254823
4 April 2018
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6385119
6 October 2017
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6282602
14 September 2016
Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6000868
25 March 2016
Industry Initiated Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5843435
23 October 2015
Administration
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5749138
6 April 2015
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5098299
2 October 2012
Industry Initiated Exam · MTSA Verification
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4455141
23 August 2012
Administration
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4419641
5 November 2010
DAPI Audit
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 3887975
21 April 2009
Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3457680
21 March 2007
MTSA Verification · Uninspected Other
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2907252
10 March 2006
Uninspected Other
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2601649
29 October 2003
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1942425
30 June 1997
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 452051
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 May 2025
Resolved
Nonmetallic flexible hose is acceptable if it: Is used in lengths of not more than 0.76 meters (30 inches. Fuel hose on new forward generator exceeded length necessary, shorten hose to meet above requirement.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 June 2025
Resolved 30 May 2025
Resolution: Hose shortned.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 May 2025
Resolved
Portable and semi-portable fire extinguishers must be inspected, maintained, and tested in accordance with the inspection, maintenance procedures, and hydrostatic pressure tests required by Chapters 7 and 8 of NFPA 10, Standard for Portable Fire Extinguishers. Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. No monthly inspections conducted. Educated operator on requirements.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 May 2025
Resolved 28 May 2025
Resolution: Educated operator on requirements.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 27 May 2025
Resolved
Records of drills and instruction must be maintained in the TVR, official logbook. (1) The date of the drill and instruction;(2) A description of the drill scenario and instruction topics;(3) The personnel involved. Drill records state "fire drill". Educated master on requirement for details.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 28 May 2025
Resolved 28 May 2025
Resolution: Educated master on requirement for details.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 March 2024
Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. Vessel has two heat detectors, and only one is operational. Prove proper operation of inoperable engine room heat detector prior to commercial operations.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 6 December 2024
Resolved 6 March 2024
Resolution: Replaced heat detector.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 March 2024
Resolved
Fire detection systems installed on board vessels shall be tested and maintained in accordance the the manufacturers design manual. Vessel/crew could not provide testing or manual for installed fire detection system. Provide annual test report for fire detection system.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2024
Resolved 18 March 2024
Resolution: Provided Service report
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 February 2024
Resolved
A towing vessel subject to this subchapter and choosing the Coast Guard inspection option, or required to have the Coast Guard inspection option, must undergo an annual inspection within 3 months before or after the COI anniversary date. Owner did not schedule annual inspection during 6 month inspection window or provide Master on day requested past due annual inspection. COI invalidated. New COI inspection required prior to commercial operations.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 16 February 2024
Resolved 6 March 2024
Resolution: New COI inspection completed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 February 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. #1 generator, while operating, found difficulty maintaining load. Diagnose cause, repair as necessary and demonstrate operation to Marine Inspector. Operational status of #2 generator undetermined. Confirm status (lock/out tag/out) or demonstrate operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2024
Resolved 6 March 2024
Resolution: Gnerator returned to service and operationally tested
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 February 2024
Resolved
Electrical systems and equipment must function properly
and minimize system failures and fire and shock hazards.
Electro-Motor connection box for heat circulating pump in gear locker in fidley room missing cover with wire exposed. Secure unit.
Port side upper engine room missing globe for light. Replace globe/shield.
Starboard side near #2 generator has loose wiring. Secure wiring.
02 junction boxes in under-deck bridge battery compartment found open with twist on wire connections exposed and/or loose wires. Secure wires within junction boxes.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2024
Resolved 6 March 2024
Resolution: Loose wiring secured, lights replaced and junction box installed
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 February 2024
Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. The owner or managing operator must ensure the following: The system is installed, tested, and maintained in accordance with the manufacturer's design manual. Test system in accordance with manual in presence of Marine Inspector
or provide 3rd party testing record.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2024
Resolved 6 March 2024
Resolution: 3rd party testing of fire detection system completed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 February 2024
Resolved
Each towing vessel must be equipped with a means to
detect smoke in berthing spaces and lounges that alerts
individuals in those spaces.01 berthing space lacks smoke detection. Install UL 217 approved smoke detector in space.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2024
Resolved 6 March 2024
Resolution: smoke detector installed
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 15 February 2024
Resolved
A record of the type, size, and service of each towline, face wire, and spring line, used to make the towing vessel fast to her tow, must be available to the Coast Guard or third-party auditor for review. The results of the inspections required by 33 CFR 164.76 must be documented in the TVR. No records onboard. Provide records.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2024
Resolved 6 March 2024
Resolution: records provided
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 15 February 2024
Resolved
A navigation assessment entry must be recorded in the TVR, official log, or in accordance with the TSMS applicable to the vessel. Navigation assessments not onboard. Provide assessments for review.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2024
Resolved 6 March 2024
Resolution: navigation assessments provided
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 February 2024
Resolved
Fuel systems for towing vessel main engines and generators must have a documented maintenance plan to ensure proper operation of the system. Plan not onboard. Provide plan.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2024
Resolved 6 March 2024
Resolution: maintenance plan provided
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 February 2024
Resolved
All crewmembers must be provided with health and safety information and training that includes: Refresher training must be repeated annually. All training
required must be documented in owner/operators records.
No records onboard. Provide records.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 February 2024
Resolved 6 March 2024
Resolution: health and safety training records provided
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 October 2022
Resolved
Each lifejacket must have a lifejacket light. Lifejacket in pilot house missing battery for light.
CITE
46 CFR 141.340(g)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2022
Resolved 8 December 2022
Resolution: Battery replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 October 2022
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. Alarms for forward generator were not working on panel despite generator shutdown as intended by problem. Repair panel for forward generator and retest alarms.
CITE
46 CFR 143.230(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2022
Resolved 8 December 2022
Resolution: Repaired panel for forward generator and retested alarms.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 October 2022
Resolved
Machinery components that exceed 220 °C (428 °F) must be insulated. Backing on burner in engine room was rusted. Replace back.
CITE
46 CFR 143.220(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2022
Resolved 8 December 2022
Resolution: Replaced back.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 October 2022
Resolved
Electrical systems and equipment must function properly
and minimize system failures and fire and shock hazards.
110V panel on the bottom had holes from where wires once were. Plug holes.
CITE
46 CFR 143.400(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2022
Resolved 8 December 2022
Resolution: Plugged holes.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 October 2022
Resolved
Electrical systems and equipment must function properly
and minimize system failures and fire and shock hazards. Found extension cords throughout vessel that were being used as permanent connection means of power source for electrical items. Remove extension cords.
CITE
46 CFR 143.400(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2022
Resolved 8 December 2022
Resolution: Removed extension cords
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 October 2022
Resolved
Electrical systems and equipment must function properly
and minimize system failures and fire and shock hazards. Found fan set up in berthing that was tied to pipe and was receiving power via multiple extension cords. Prior to completion of inspection, fan set up was removed from the vessel and disposed of.
CITE
46 CFR 143.400(a)
Action required: 10 - Deficiency Rectified
Resolved 14 October 2022
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 15 October 2021
Resolved
The emergency duties and duty stations required by this section must be posted at each operating station and in a conspicuous location in a space commonly visited by crew members.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2021
Resolved 14 December 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 August 2021
Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the associated fleet that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 October 2021
Resolved 15 October 2021
Resolution: Conducted COI inspection
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 July 2021
Resolved
Lifejackets must be readily accessible. Stowage containers must be marked in block capital letters and numbers with the minimum quantity, identity. May be identified in words or with the appropriate IMO symbol. Lifejackets are stowed under a seat and are not readily accessible or properly marked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2021
Resolved 14 December 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 July 2021
Resolved
The frame or support of any semi-portable (B-V) fire extinguisher fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it from rolling. The semi portable is currently secured by a fabric ratchet strap.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2021
Resolved 14 December 2021
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 5 November 2010
Resolved
Hotline number not displayed
Due 12 November 2010
Resolved 5 November 2010
Resolution: Hotline number posted
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 5 November 2010
Resolved
Random testing not spread evenly throughout the year. No evidence of first quarter testing conducted. Marine Employer must provide an acknowledgement letter from Comprehensive Testing Solutions for addition of first quarter testing.
Due 12 November 2010
Resolved 8 November 2010
Resolution: Documentation provided for random drug testing spread evenly throughout the year.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 5 November 2010
Resolved
Substance Abuse Professional name and contact information not available at time of inspection.
Due 12 November 2010
Resolved 8 November 2010
Resolution: SAP name and contact info provided.
Communications › Radio Communications › EPIRB
Issued 21 April 2009
Resolved
Epirb not present
Action required: 705 - Other - as specified
Resolved 24 April 2009
Resolution: New epirb on board.