Records from 2006 to 2023. Most recent: inspection, 23 October 2023.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 October 2022
Resolved
Each towing vessel must be equipped with an industrial
type first aid kit, appropriate to the size of the crew
and operating conditions. Ammonia inhalants first aid
kit were expired. Replace expired item.
CITE
46 CFR 140.435
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2022
Resolved 8 December 2022
Resolution: Replaced expired item
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 October 2022
Resolved
Each lifejacket must have a lifejacket light. Batteries for lifejacket lights were dying. Replace batteries.
CITE
46 CFR 141.340(g)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2022
Resolved 8 December 2022
Resolution: Replaced batteries.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 October 2022
Resolved
Stowage positions for lifejackets stowed in a berthing space or stateroom and all lifejacket containers must be marked in block capital letters and numbers with the minimum quantity. Lifejacket stowage was not marked. Mark stowage.
CITE
46 CFR 141.340(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2022
Resolved 8 December 2022
Resolution: Marked stowage
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 October 2022
Resolved
Lifebuoys must be fitted with a floating electric water light approved under approval series 161.010 or 161.110. Water light battery for port main deck was expired. Replace battery.
CITE
46 CFR 141.360(c)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2022
Resolved 8 December 2022
Resolution: Replaced battery.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 October 2022
Resolved
Electrical systems and equipment must function properly
and minimize system failures and fire and shock hazards. Switch box for navigation lights was missing switches and had openings. Plug openings.
CITE
46 CFR 143.400(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2022
Resolved 8 December 2022
Resolution: Plugged openings
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 October 2022
Resolved
Electrical systems and equipment must function properly
and minimize system failures and fire and shock hazards. Outlet face plate in towing gear room was lifting at the corner. Replace plate.
CITE
46 CFR 143.400(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2022
Resolved 8 December 2022
Resolution: Replaced plate
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 October 2022
Resolved
Electrical systems and equipment must function properly
and minimize system failures and fire and shock hazards.
Breaker panel by generator had opening between breakers. Plug opening.
CITE
46 CFR 143.400(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2022
Resolved 8 December 2022
Resolution: Plugged opening
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 October 2022
Resolved
Electrical systems and equipment must function properly
and minimize system failures and fire and shock hazards. Found extension cords throughout vessel that were being used as permanent connection means of power source for electrical items. Remove extension cords.
CITE
46 CFR 143.400(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2022
Resolved 8 December 2022
Resolution: Removed extension cords
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 July 2021
Resolved
All bilges and void spaces are to be kept free from accumulation of combustible and flammable liquids. All seals and gaskets must be properly maintained to prevent leaks of flammable/combustible liquids. Bilges were found to contain excessive oil. Bilges to be kept free from oil and suspect source of oil found and controlled.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 19 August 2021
Resolution: Bilges were clean and free of oil
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 July 2021
Resolved
Essential systems must be regularly tested and examined. Crew could not readily test the bilge high level alarms in the engine room, and due to the complexity and lack of labeling or emergency instructions in the engine room, were unable to demonstrate the ability to de-water the engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 19 August 2021
Resolution: Crew has been trained and clear instructions have been posted on bilge system operations. Tested high bilge alarm.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 July 2021
Resolved
The operator of each self propelled vessel 12 meters or more in length shall carry on board and maintain for ready reference a copy of these rules. Navigation rules on board are out dated. Provide updated hard or electronic copy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 19 August 2021
Resolution: Vessel enrolled in auto chart and pub updating system.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 13 July 2021
Resolved
Towing vessels must be equipped with an illuminated magnetic compass. Magnetic compass on board does not give an accurate heading. Provide updated deviation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 8 December 2022
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 July 2021
Resolved
The results of the inspections required by 33 CFR 164.76 must be documented in the TVR, official logbook, or IAW the TSMS applicable to the vessel. No record was found in the TVR covering the items required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2021
Resolved 19 August 2021
Resolution: Company created procedures for logging the required inspections in the TVR.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 September 2020
Resolved
Each life jacket must have a whistle firmly secured by a cord to the life jacket. Each life jacket must have a light securely attached to the front shoulder area. Life jackets did not have whistles and batteries were found dead. Provide whistles and working batteries for all life jackets as required.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2020
Resolved 13 November 2020
Resolution: Verified whistles and lights on lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 September 2020
Resolved
Each towing vessel must carry at least one life jacket for each person on board. Vessel was missing one Life jacket which was brought on board during inspection.
Action required: 10 - Deficiency Rectified
Due 22 October 2020
Resolved 22 September 2020
Resolution: additional life jacket placed on board
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 September 2020
Resolved
Lifebuoys must have lifelines secured around the body and at least two lifebuoys must have lights. Lifeline were found deteriorated and batteries were expired. Replace line and battery as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2020
Resolved 13 November 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 September 2020
Resolved
Each vessel must be equipped with shapes in accordance with COLREGS or 33CFR part 84. Vessel does not have day shapes. Provide shapes as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2020
Resolved 13 November 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Document of Compliance (DoC/ ISM)
Issued 22 September 2020
Resolved
The person in command of a documented vessel must have onboard that vessel the original Certificate of Documentation currently in effect for that vessel. COD was not onboard
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2020
Resolved 8 October 2020
Resolution: Notarized copy of COD was placed in binder at the operating station
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 September 2020
Resolved
Original COI must be framed under glass or other transparent material and posted in a conspicuous place onboard the towing vessel. COI was not posted. Vessel to post as required.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2020
Resolved 13 November 2020
10 - Safety of Navigation › N/A - No Subsystem › Signalling lamp
Issued 22 September 2020
Resolved
Towing vessel must have search light. Search light found inoperable. Vessel to replace bulb and prove functionality.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2020
Resolved 8 October 2020
Resolution: Searchlight has been repaired
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 September 2020
Resolved
Each remote valve control must be marked in clearly legible letters at least 1" high indicating purpose of valve and the way to operate it. Fuel shut off was not labeled as required. Vessel to label valve per CFR.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2020
Resolved 8 October 2020
Resolution: Fuel shut off has been labeled and tested
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 September 2020
Resolved
There must be an installed or portable bilge pump for emergency dewatering. Fixed bilge pump found inoperable. Vessel to repair bilge system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2020
Resolved 13 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 September 2020
Resolved
Piping that exceeds 428F must be insulated. Exhaust piping found missing insulation. Vessel to replace insulation as required.
11/13/20 aft generator missing insulation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2020
Resolved 8 December 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 September 2020
Resolved
A supply of spare fuel filters must be provided on board. Vessel to verify filters are on board vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2020
Resolved 8 October 2020
Resolution: Spare fuel filters have been placed on board
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 September 2020
Resolved
Fire hoses are to be inspected for wear and subjected to a test pressure equal to service pressure. Fire hose and valve started leaking at max service pressure. Vessel to replace hose and repair valve as required. The hose must be commercial lined, 50' length and 1.5"diameter.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2020
Resolved 8 October 2020
Resolution: Fire hose has been replaced and leak has been repaired
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 September 2020
Resolved
All bilges and void spaces are to be kept free from accumulation of combustible and flammable liquids. All seals and gaskets must be properly maintained to prevent leaks of flammable/combustible liquids. Bilges were found to contain oil/water. Bilges to be pumped and kept free from oil as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2020
Resolved 13 November 2020
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 22 September 2020
Resolved
Towing vessel with overnight accommodations and alternating watches must have a system to detect when its master becomes incapacitated. Verify Pilothouse Alerter System. Proved as required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2020
Resolved 8 October 2020
Resolution: It has been found that this requirement is not due intil next COI issuance
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 22 September 2020
Resolved
Stow Fire extinguishers IAW manufacturer recommendation.
Fire extinguisher in galley is not in approved bracket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2020
Resolved 13 November 2020
Resolution: Proper bracket was installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 September 2020
Resolved
The following items to be verified:
Witness Drills, Fuel shut off from pull stations,
Engine alarms, Radio check, Fire detection functioning
11/13/20- fire detection functioning required to be verified.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2020
Resolved 8 December 2022
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 5 November 2010
Resolved
Random testing not spread evenly throughout the year. No evidence of first quarter testing conducted. Marine Employer must provide an acknowledgement letter from Comprehensive Testing Solutions for addition of first quarter testing.
Due 12 November 2010
Resolved 8 November 2010
Resolution: Documentation provided for random drug testing spread evenly throughout the year.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 5 November 2010
Resolved
Hotline number was not displayed
Due 12 November 2010
Resolved 5 November 2010
Resolution: Hotline number posted
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 5 November 2010
Resolved
Substance Abuse Professional name and contact information not available at time of inspection.
Due 12 November 2010
Resolved 8 November 2010
Resolution: SAP name and contact info provided.
Fire Fighting › Fire Pumps › Arrangement
Issued 7 November 2006
Resolved
Vessel had portable pump onboard, but master stated that it could not be run because it was also used to pump bilges and may have oil in it. Required vessel to provide portable pump designated solely as fire pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2006
Resolution: Fire pump onboard & tested.
Fire Fighting › Fire Hoses › Number
Issued 7 November 2006
Resolved
No firefighting hoses onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2006
Resolution: Hoses onboard.
Fire Fighting › Nozzles › Number
Issued 7 November 2006
Resolved
No firefighting nozzel onboard
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2006
Resolution: Verified firefighing nozzel onboard.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 7 November 2006
Resolved
Vessel master did not have license onboard vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2006
Resolution: Master''s license onboard.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 7 November 2006
Resolved
MSD overboard discharge device not permanently secured.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2006
Resolution: Removed MSD overboard discharge valve handle.
Engineering › Fuel Oil Service System › Valve
Issued 7 November 2006
Resolved
No remote fuel shut-off valves at fuel tank.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2007
Operations/Management › Drills/Instruction › Fire
Issued 7 November 2006
Resolved
No proof of required fire drills and crew training.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2007
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 7 November 2006
Resolved
Noted significant wastage in bow void, stern voids, on gunnel and supporting gussets, 4" hole on bow, 2" hole on port stern, 3' crack on port pilothouse starting on main deck and propogating upward at midbody area.
Action required: 705 - Other - as specified
Resolved 1 August 2007
Resolution: Repairs have been made.
Communications › Alarms/Indicators › General Alarm
Issued 7 November 2006
Resolved
No warning sign for general alarm in engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2007
Resolution: Warning sign posted.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 7 November 2006
Resolved
Vessel did not have required depth sounding device onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2007
Resolution: Deoth sounding device has been installed.
Navigation › Piloting/Steering › Marine Charts
Issued 7 November 2006
Resolved
Vessel's charts severely outdated.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2007
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 7 November 2006
Resolved
No Local Notice to Mariners onboard vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2007