Records from 2004 to 2012. Most recent: inspection, 17 January 2012.
Inspection history · 21
17 January 2012
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4224333
6 January 2012
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4218993
29 July 2011
Damage Survey · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4103079
28 July 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4135312
26 February 2010
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3686631
10 February 2010
Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3675102
30 March 2009
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3445686
27 March 2009
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3442692
27 March 2009
Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3442694
19 March 2009
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3436351
8 January 2008
Hull Examination · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3126917
20 July 2007
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3001697
2 February 2007
Damage Survey · COI Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2867659
29 January 2007
Damage Survey · Examination of Repairs · Administrative Inspection · Permit to Proceed
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2863412
26 January 2007
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3022593
10 January 2006
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2564122
24 February 2005
Internal Structural Exam · Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2299104
16 July 2004
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2153579
16 July 2004
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2155170
16 July 2004
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2170741
27 February 2004
Hull Examination · Plan Review "T" Boat · Initial Certification · Internal Structural Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2004964
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 10 February 2010
Resolved
Make repairs to port inboard propeller in way of old repairs or replace.
Action required: 705 - Other - as specified
Resolved 1 March 2010
Resolution: Propeller was replaced.
Accommodation/Occupational Safety › Washroom/Toilet › Location
Issued 10 February 2010
Resolved
Replace plastic fittings and make repairs to copper tubing that penetrate forward bulkhead of grey water tank room.
Action required: 705 - Other - as specified
Resolved 1 March 2010
Construction/Loadline › Penetrations › Weld
Issued 10 February 2010
Resolved
Weld up deck penetration on starboard side overhead in grey water tank room.
Action required: 705 - Other - as specified
Resolved 1 March 2010
Engineering › Freshwater System (jacketwater cooling) › Valve
Issued 10 February 2010
Resolved
Provide and install valve handle for starboard side generator keel cooler.
Action required: 705 - Other - as specified
Resolved 1 March 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 10 February 2010
Resolved
Make repairs to all lagging in engine room.
Action required: 705 - Other - as specified
Resolved 1 March 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 10 February 2010
Resolved
Properly support reduction gear cooling water overboard piping.
Action required: 705 - Other - as specified
Resolved 1 March 2010
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 10 February 2010
Resolved
Replace plastic cbg fittings in aft engine room bulkhead port side.
Action required: 705 - Other - as specified
Resolved 1 March 2010
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 10 February 2010
Resolved
Properly mount all raw water cooling strainers in the engine room.
Action required: 705 - Other - as specified
Resolved 1 March 2010
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 10 February 2010
Resolved
Secure fuel oil leaks at tank on starboard side in way of shut off valve.
Action required: 705 - Other - as specified
Resolved 1 March 2010
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 10 February 2010
Resolved
Provide and install metal plugs in fuel oil tank drains.
Action required: 705 - Other - as specified
Resolved 1 March 2010
Construction/Loadline › Hull › Bottom Plating
Issued 10 February 2010
Resolved
Crop and renew severly pitted areas in forepeak on port and starboard sides as marked and discussed.
Action required: 705 - Other - as specified
Resolved 1 March 2010
Construction/Loadline › Hull › Side Shell
Issued 27 March 2009
Resolved
Crop and renew approx 6' x 3'6" aluminum portion of afterdeck and 2'6" x 6' section of transom where the transom meets the afterdeck. Renew plating and internal longitudinal framing as original prior to departure from drydock in Morgan City, LA.
Action required: 705 - Other - as specified
Resolved 27 March 2009
Resolution: Inspected and cleared on activity # 3445686.
Engineering › Steering Gear System › Rudder
Issued 22 February 2007
Resolved
Provide a limit switch to stop the steering gear before it reaches the rudder stops as required by 46 CFR 182.610 (e)(5)
Action required: 705 - Other - as specified
Due 22 March 2007
Resolved 23 February 2007
Resolution: Shipyard installed limit switches that keep the steering gear from reaching the rudder stops.
Construction/Loadline › Hull › Hull Plating
Issued 29 January 2007
Resolved
Vsl hit submerged object witch caused 2 holes in the fwd birthing compartment. A box patch was placed over both holes to transit for permanent repairs.
Action required: 705 - Other - as specified
Resolved 14 February 2007
Resolution: Witnessed satisfactory test of repairs made to hull in areas of damage, inspected entire hull all sat.
Navigation › Piloting/Steering › Marine Charts
Issued 24 February 2005
Resolved
Chart 11347 missing.
Due 25 February 2005
Resolved 25 February 2005
Construction/Loadline › Hull › Hull Plating
Issued 24 February 2005
Resolved
Gouge and reweld welds cut from stern quarters.
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 28 February 2005
Construction/Loadline › Hull › Longitudinal Frame
Issued 24 February 2005
Resolved
Crop and renew three tripped longitudinals in the port quarter.
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 28 February 2005
Operations/Management › Passenger Operations › Safety Orientation
Issued 24 February 2005
Resolved
Post orientation.
Due 25 February 2005
Resolved 24 February 2005
Fire Fighting › Means of Escape › Escape Route Signs
Issued 24 February 2005
Resolved
Post signs for all escapes.
Due 25 February 2005
Resolved 24 February 2005
Fire Fighting › Means of Escape
Issued 23 February 2004
Resolved
Adjust emergency escape hatches in engine room, aft steering, and passenger lounge as required by 46 CFR 177.500. LEGACY COMPONENT DESC: Hatches
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 February 2004
Resolved 25 February 2004
Resolution: Witnessed a satisfactory hose test of all emergency escape hatches.
Engineering › Bilge Water Management System
Issued 23 February 2004
Resolved
Label bilge alarm panel located in pilot house as required by 46 CFR 182.530. LEGACY COMPONENT DESC: Alarm Panel
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 February 2004
Resolved 25 February 2004
Resolution: Ship''''s crew labeled bilge alarm panel.
Engineering › Steering Gear System
Issued 23 February 2004
Resolved
Tighten rudder and shaft packing as required by 46 CFR 176.802(c). LEGACY COMPONENT DESC: Rudder Bearing
Action required: 705 - Other - as specified
Due 27 February 2004
Resolved 25 February 2004
Resolution: Witnessed the proper adjustment of the rudder and shaft packing.
Engineering › Steering Gear System
Issued 23 February 2004
Resolved
Prove proper operation of the rudder angle indicator as required by 46 CFR 182.610(f)(2). LEGACY COMPONENT DESC: Rudder Angle Indicator
Action required: 705 - Other - as specified
Due 27 February 2004
Resolved 25 February 2004
Resolution: Witnessed a satisfactory test of the rudder angle indicator.
Engineering › Bilge Water Management System
Issued 23 February 2004
Resolved
Label bilge manifold. LEGACY COMPONENT DESC: Manifold
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 February 2004
Resolved 25 February 2004
Resolution: Witnessed the proper labeling of the bilge manifold.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 23 February 2004
Resolved
Repair exhaust leaks on #1 and #3 main diesel engines as required by 46 CFR 182.430(b). LEGACY COMPONENT DESC: Spark Arrestor (exhaust)
Action required: 705 - Other - as specified
Due 27 February 2004
Resolved 25 February 2004
Resolution: Inspected the proper repair of the exhaust leaks on #1 and #3 main diesel engines.
Documentation › Certificates/Documents
Issued 23 February 2004
Resolved
Provide Load Line Certificates. LEGACY COMPONENT DESC: Coastwise Load Line Certificate
Action required: 705 - Other - as specified
Due 27 February 2004
Resolved 27 February 2004
Resolution: Received a copy of the Load Line Certificate.
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 23 February 2004
Resolved
Provide Red Cross first aid/CPR cards for 50% of the crew.
Action required: 705 - Other - as specified
Due 27 February 2004
Resolved 25 February 2004
Resolution: Verified that atleast 50% of the crew had a Red Cross first aid/CPR cards.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 23 February 2004
Resolved
Provide operator's license as required by 46 CFR 185.402.
Action required: 705 - Other - as specified
Due 27 February 2004
Resolved 25 February 2004
Resolution: Verified that the operator had a valid license.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 23 February 2004
Resolved
Conduct an abandon ship drill as required by 46 CFR 185.520.
Action required: 705 - Other - as specified
Due 27 February 2004
Resolved 25 February 2004
Resolution: Witnessed a satisfactory abandon ship drill.
Operations/Management › Drills/Instruction › Fire
Issued 23 February 2004
Resolved
Conduct a fire drill as required by 46 CFR 185.524.
Action required: 705 - Other - as specified
Due 27 February 2004
Resolved 25 February 2004
Resolution: Witnessed a satisfactory fire drill.
Engineering › Pressure Vessel
Issued 23 February 2004
Resolved
Provide proper relief valve for hot water heater as required by 46 CFR 182.320.
Action required: 705 - Other - as specified
Due 27 February 2004
Resolved 25 February 2004
Resolution: Inspected the installation of a approved relief valve for the hot water heater.