K MARINE XXII is a 2007 offshore supply vessel. The Coast Guard has recorded 11 inspections since 2017, most recently in March 2026, along with 12 deficiencies and 2 casualty investigations between 2011 and 2013.
Records from 2011 to 2026. Most recent: inspection, 27 March 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
DocumentationValid · issued 29 April 2026 · expires 30 April 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1153 - Convention (Subpart B), Gross Ton 345 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 March 2026Resolved
Electrical equipment on a vessel must be designed, installed, and maintained to minimize accidental personal contact with energized parts. Emergency generator main switchboard had open wires exposed behind breaker, exposed opening needs to be covered
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2026
Resolved 30 March 2026
Resolution: Blanks were placed in the spot of all openings
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 March 2026Resolved
Visible and audible alarms must be installed for each main propulsion engine high jacket-water temperature. when High jacket-water temperature exceeds temp alarm needs to sound. High jacket-water temperature alarm did not sound on the STBD main engine when tested.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2026
Resolved 30 March 2026
Resolution: Received high water temp service report from tech that repaired the system on the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 27 March 2026Resolved
Crew members must be able to demonstrate operation of each self-closing fire door. Self-closing fire doors on vessel were found unable to close automatically presenting a safety risk in the event of fire. Fire doors are required to be self-closing must close without assistance of a crew member.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2026
Resolved 17 April 2026
Resolution: Received video of all fire doors properly closing
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 27 March 2026Resolved
Rescue boat needs appropriate markings on the vessel and a searchlight. Searchlight was purchased still awaiting markings. Must be plainly marked or painted on each side of bow of rescue boat in block capital letters and numbers; name of vessel, number of the boat, name of port, length & beam of boast, number of persons the boat will hold.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2026
Resolved 9 April 2026
Resolution: Recieved photos of corrected rescue boat markings in place
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 27 March 2026Resolved
Each vessel must be designed and constructed to minimize fire hazards, as far as reasonable and practicable. Fire dampner louvers for the emergency generator room were wasted and need to be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2026
Resolved 15 April 2026
Resolution: Received invoice for the ordered dampners enroute for installation.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 20 February 2025Resolved
The following tests and inspections of fire-extinguishing equipment must be performed by the owner, operator, or master, or by a qualified servicing facility, to verify compliance with paragraph (a) of this section. CO2 system was not fully operating due to a faulty switch, keeping ventilation from shutting off.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2025
Resolution: MI's went onboard to test repairs to CO2 system. Remote actuation of ventilation to shut-off during CO2 system test now operational.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 February 2025Resolved
Provide services necessary for the safety under normal and emergency conditions; Prevent electrical ignition of flammable vapors. Dryer vent lead directly to bulkhead with no lint trap, posing a fire hazard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 March 2025
Resolution: Vessel rep provided photo documentation showing newly installed lint trap for onboard dryer.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management Plan (BWMP)
Issued 20 February 2025Resolved
This subpart applies to all non-recreational vessels, U.S. and foreign, that are equipped with ballast tanks and operate in the waters of the United States, except as expressly provided in § 151.2015 or § 151.2020 of this subpart. Vessel needs new Ballast Water Management Plan IAW 33 CFR Subchapter O Part 151 Subpart D.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 March 2025
Resolution: Vessel rep provided BWMP via electronically and MI verified updated plan IAW with their ballast water management procedures.
STCW II/4, III/4: 01 OS did not have proper STCW stamps for deck watch standing. 01 QMED did not have the proper STCW stamps for engineering watch standing. Crewmembers shall not stand underway watch until corrected.
Action required: 705 - Other - as specified
Due 10 May 2023
Resolved 17 April 2023
Resolution: Crewmembers replaced with properly credentialed mariners.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 10 April 2023Resolved
46 CFR 132.350(c)(2)(iv) Each semiportable fire extinguisher and each fixed fire-extinguishing system must be inspected and tested to determine that alarms and ventilation shutdowns for each fire-extinguishing system operate properly. The following vent dampers were inoperable:
01 deck e-gen air intake
01 deck e-gen blower
01 deck stove vent
01 deck comp vent
02 deck stbd side
Action required: 17 - Rectify deficiencies prior to departure
Due 14 May 2023
Resolved 17 April 2023
Resolution: Vent dampers repaired and OPTEST SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 April 2023Resolved
56.50-50 Bilge and ballast piping.
(a)
(1) All vessels except unmanned barges shall be provided with a satisfactory bilge pumping plant capable of pumping from and draining any watertight compartment except for ballast, oil and water tanks which have acceptable means for filling and emptying independent of the bilge system. Test bilge pumping system in the presence of a MI.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 May 2023
Resolved 17 April 2023
Resolution: Bilge pumping system operability tested by filling forepeak with potable water and pumping overboard. SAT.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 6 February 2017Resolved
System for detecting smoke and fire not operational. Repair to satisfaction of marine inspector. 46CFR132.350(c)(4)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 February 2017
Resolution: Tested smoke detectors and thermal detectors panel. All satisfactory.
28 July 2011Routine · role: Involved in a Marine Casualty · activity 4135312
12 August 2013Routine · role: Involved in a Marine Casualty · 1 dead · activity 4682703
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.