Records from 2004 to 2025. Most recent: inspection, 2 September 2025.
Inspection history · 28
2 September 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8224881
9 May 2024
COI Inspection · Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7908221
12 April 2024
Inclining Experiment · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7904903
7 February 2024
Drydock Exam · Examination of Repairs · Construction Oversight · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7857756
3 March 2021
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7149462
31 July 2020
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7020803
12 March 2019
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6640736
28 February 2019
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6634333
16 July 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6480914
21 June 2018
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6451633
30 January 2018
Drydock Exam · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6346332
17 April 2017
COI Inspection · Examination of Repairs · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6126710
16 March 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5834727
11 March 2014
Hull Examination · Internal Structural Exam · Administrative Inspection · Examination of Repairs · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4814745
2 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4200214
8 March 2010
Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3691745
12 March 2009
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3432086
10 March 2008
Annual Inspection · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3161455
18 June 2007
Periodic Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2965619
17 January 2007
Damage Survey
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2857516
18 May 2006
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2652472
17 May 2006
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2652435
14 March 2006
Internal Structural Exam · Re-Inspection · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2679921
19 April 2005
Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2337453
27 July 2004
Examination of Repairs · Damage Survey
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2146486
26 July 2004
Damage Survey
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2145425
20 July 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2140490
4 March 2004
Initial Certification · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2017888
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 2 September 2025
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 September 2025
Resolved 2 September 2025
Resolution: Crew tightened dogs on watertight doors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 March 2019
Resolved
Cracked exhaust piping on #2 MDE
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2019
Resolved 13 March 2019
Resolution: Owner gouged and rewelded crack
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 March 2019
Resolved
Soft patch on piping elbow for raw water system on #1 MDE.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2019
Resolved 13 March 2019
Resolution: Owner removed soft patch and installed fixed piping
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 12 March 2019
Resolved
#1, #2, and #3 MDE missing alarm lights for overspeeds and emergency shutdowns. Owner shall either replace the light or install a cover over the holes to prevent accidental personnel shock.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2019
Resolved 13 March 2019
Resolution: Owner installed new alarm lights for all control panels
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 March 2019
Resolved
Cracked hose on fixed CO2 fire fighting system for generator compartment.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2019
Resolved 13 March 2019
Resolution: Owner replaced with new hose
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 March 2019
Resolved
Soft patch installed on port side generator.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2019
Resolved 13 March 2019
Resolution: Owner removed soft patch and installed fixed piping
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 16 July 2018
Resolved
Adjust all QAWTDs to make watertight-hinges/dogging devices were loose.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 July 2018
Resolved 18 July 2018
Resolution: Watertight door hinges/devices satisfactorally repaired
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 16 July 2018
Resolved
One auxiliary line consisting of at least 500ft of 3inches circuference manilla complying with federal specification T-R-605-Vessel did not have auxiliary line present
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 20 July 2018
Resolved 18 July 2018
Resolution: Auxiliary line purchased
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 16 July 2018
Resolved
Provide and install blank in electrical panel stbd of the AFT engine room QAWTD
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 July 2018
Resolved 18 July 2018
Resolution: Blank intalled
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 July 2018
Resolved
Replace #2 MDE Fuel/Oil return hose with one meeting J-1942
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 July 2018
Resolved 18 July 2018
Resolution: f/o hose replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 July 2018
Resolved
Make weld repaires to pin hole in #3 MDE Exhaust
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 20 July 2018
Resolved 18 July 2018
Resolution: Pin hole repaired.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 July 2018
Resolved
Make operable ground indicator on switchboard
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 20 July 2018
Resolved 18 July 2018
Resolution: Ground detection gauge fixed
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 July 2018
Resolved
Properly terminate dead end wire for stbd engine room blower fan
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 July 2018
Resolved 18 July 2018
Resolution: blower fan wire properly fixed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 July 2018
Resolved
Replaced expired items in first aid kits
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 20 July 2018
Resolved 18 July 2018
Resolution: All items in first aid kit are valid.
Electrical › Electric Generation Source (service) › Generator
Issued 28 April 2017
Resolved
P/S generators not equipped with proper data plates indicating service capability in 50degC ambient temperature.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 May 2017
Resolved 28 April 2017
Resolution: Vessel had new data plates indicating service for 50degC ambient temperature made and installed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 28 April 2017
Resolved
CO2 cylinders installed sitting directly on metal grating. Dissimilar metals causing corrosion of the CO2 cylinders.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 May 2017
Resolved 28 April 2017
Resolution: Vessel installed a wooden plank under the CO2 cylinders as a barrier between the dissimilar metals to arrest further corrosion.
Lifesaving › Launching Appliances › Lines
Issued 12 March 2009
Resolved
Provide means to recover unconcious man overboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2009
Resolution: Provided rescue harness and line.
Fire Fighting › Fire Main › Condition
Issued 12 March 2009
Resolved
Repair bilge piping for fire system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2009
Resolution: Pinhole leak welded.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 18 June 2007
Resolved
Distribution line for CO2 piping must extend 2 inches beyond the last orifice and be closed with a cap or plug IWO generator room. IAW 46 CFR 181.410(d)(2)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2007
Resolution: Recieved attestation via fax from 3rd Party Fire Suppression system Company that repairs have been made.
Lifesaving › Lifefloat › Platform
Issued 18 June 2007
Resolved
Life floats must have spacers between floats IAW 46 CFR 180.137(f)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2007
Resolution: Witnessed satisfactory installation.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 18 June 2007
Resolved
Vessels Crew must provide CPR Cards for certification of 50% OF THE CREW IAW NVIC 01-91.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2007
Resolution: Rcvd faxed copies of certification cards of the crew.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 June 2007
Resolved
Repair hole/fracture IWO Jacket Water exhaust cooling on the Port and Stbd inboard MDE's.
Condition: Unknown
Due 23 June 2007
Resolved 19 June 2007
Resolution: Rcvd attestation from repair tech/welder for weld repair for SS exhaust jacket water piping.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 18 June 2007
Resolved
Vessel must repair/replace electrical relay of emergency power to VHF radio's. IAW 46 CFR 183.310 (a)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2007
Resolution: Technician discovered battery back-up supply was dead. Installed new battery. CG Witnessed satisfactory test.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 15 March 2006
Resolved
International Load Line Certificate not on board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 March 2006
Resolution: Corrected.
Navigation › Piloting/Steering › Marine Charts
Issued 15 March 2006
Resolved
Provide updated charts and nautical publications as required.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 March 2006
Resolution: Corrected.
Lifesaving › Lifefloat › Markings
Issued 15 March 2006
Resolved
Not marked on both sides and spacers not provided in between.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 March 2006
Resolution: Corrected.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 15 March 2006
Resolved
Not stenciled with vessel name.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 March 2006
Resolution: Corrected.
Communications › Radio Communications › EPIRB
Issued 15 March 2006
Resolved
Renew hydrostatic release.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 March 2006
Resolution: Corrected.
Stability › Watertight Integrity › General
Issued 15 March 2006
Resolved
Adjust all watertight doors and scuttles.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 March 2006
Resolution: Corrected.
Construction/Loadline › Hull › Bottom Plating
Issued 26 July 2004
Resolved
Prior to carriage of passengers or cargo make permanent repairs to all grounding damage.
Action required: 705 - Other - as specified
Due 20 July 2005
Resolved 27 July 2004
Resolution: No hull plate required re-newing, Port Inboard, Port Outboard shafts and propellers replaced. Port Rudder repalced. Both Port reduction gears repalced.