MAURY USCG vessel records Sign in
← All vessels

OCEAN JEWEL OF ST. PETERSBURG

OCEAN JEWEL OF ST. PETERSBURG is a 1982 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 2004, most recently in March 2006, along with 136 deficiencies — 8 with no resolution recorded — and 7 operational controls.

Records from 2004 to 2006. Most recent: operational control imposed, 4 March 2006.

Built
1982
Last inspected
4 March 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7625823 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
667453
Flag
SAINT VINCENT AND THE GRENADINES
—
Maury page id
psix-667453

Inspections, by type

…with no type recorded16
Years with a record 3 calendar years (2004–2006)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it12857 - Convention (Subpart B), Gross Ton
12602 - Simplified, Gross Ton
1647 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MOIRA MCALLISTER Towing Vessel · MISLE 667821 · 28 June 2005 · activity 2464574

Inspection history · 28

4 March 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2595867
28 February 2006 PII Safety Exam · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2593414
12 October 2005 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2514052
29 September 2005 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2504318
17 August 2005 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2465706
16 August 2005 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2464578
16 August 2005 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2465701
15 August 2005 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2467790
26 July 2005 ISPS II Exam · COC-CVE Quarterly
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2441743
25 July 2005 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2452099
28 June 2005 In-Service Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2407352
28 June 2005 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2464574
10 June 2005 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2386407
10 June 2005 Deficiency Check · ISM Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2388963
26 May 2005 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2368874
26 May 2005 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2369021
21 April 2005 COC-CVE Quarterly
Type not classified · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2339503
8 February 2005 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2289051
1 February 2005 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2285406
25 January 2005 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2280994
20 January 2005 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2277865
18 January 2005 Ballast Water Examination · ISPS II Exam · Loadline Exam · STCW 95 Exam · ILO-147 Exam · ISM Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · COC-CVE Quarterly
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2278505
17 December 2004 In-Service Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2262299
26 October 2004 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2228437
21 October 2004 COC-CVE Initial
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2004906
21 October 2004 ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2237477
1 July 2004 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2157651
27 January 2004 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1994489

Deficiency record · 136

Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 28 February 2006 Resolved
Vessel di not provide Valid certificates upon inspection, to include ISM Safety Management Certificate, ISSC (Full Term), and Certificate of Registry. Vessel to provide valid Certificates prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2006
Personnel › Training › Familiarization Training
Issued 28 February 2006 Resolved
Crew was unable to effectively perform duties as per certificates of competency. Crew to be familiar with Duties in the operation of the vessel including emergency and shipboard procedures prior to departure
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 28 February 2006 Resolved
CO2 Fire Supression System not able to be proven operable. Vessel to demonstrate proper operation prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2006
Engineering › Steering Gear System › Power Unit
Issued 28 February 2006 Resolved
Steering Pump Failure alarms not operable on the bridge or locally. Vessel to repair or prove proper operation Prior to departure.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2006
Engineering › Generator (propulsion-electric) › Switch
Issued 28 February 2006 Resolved
Vessels number three, four and five Generators inoperable due to major repairs
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2006
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 28 February 2006 Resolved
Vessels fire Door closing system was inoperable due to numerous holdbacks and improper care and lack of maintenance. Vessel ot repair and or maintenance fire doors and demonstrate proper operation/ closure of Class A fire doors by means of bridge contol system.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 March 2006
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (100 ppm)
Issued 28 February 2006 No resolution recorded
Vessels OWS is not operating. Prior to returning to the US have class attest tp proper operation of the OWS and provide report to Coast Guard.
Action required: 15 - Rectify deficiencies by next port
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 28 February 2006 No resolution recorded
Vessel has not implemented there SMS as per ISM. No evidence can be provided showing the the established procedures for maintenance of the critical equipment is being conducted.
Action required: 15 - Rectify deficiencies by next port
Electrical › Electric Generation Source (service) › Generator
Issued 17 August 2005 No resolution recorded
Effect repairs to main electical generating set. Main electrical system must comply with SOLAS 74 II-1, Reg 24. Repairs must be made to satisfaction of attending class society surveyor and attending CG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 26 July 2005 Resolved
VESSEL WAS UNABLE TO PROVIDE ORIGINAL SAFE MANNING DOCUMENT. VESSEL MUST PROVIDE ORIGINAL SAFE MANNING DOCUMENT FROM VESSEL ADMINISTRATION.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 August 2005
Resolved 15 August 2005
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 26 July 2005 Resolved
VESSEL DID NOT PRODUCE ORIGINAL CERTIFICATE OF REGISTRY WITH UPDATED NET AND GROSS TONNAGE AFTER MAJOR MODIFICATION. VESSEL MUST PROVIDE UPDATED CERTIFICATE OF REGISTRY.
Condition: Unknown
Due 9 August 2005
Resolved 15 August 2005
Documentation › Manuals/Policy Documentation › Instructions for On-board Maintenance (lifesaving)
Issued 26 July 2005 No resolution recorded
VESSEL WAS NOT ABLE TO PROVE COMPLETION OF MEASURES AIMED AT PROMOTING THE RELIABILITY OF CRITICAL EQUIPMENT. VESSEL MUST SHOW COMPLETED PMS RECORDS FOR ALL CRITICAL EQUIPMENT.
Action required: 15 - Rectify deficiencies by next port
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 26 July 2005 Resolved
VESSELS OILY WATER SEPARATOR WAS NOT FUNCTIONING DURING INSPECTION. AS PER CLASS REQUIREMENTS OILY WATER SEPARATOR MUST BE OPERATIONAL .
Due 1 August 2005
Resolved 15 August 2005
Fire Fighting › Ventilation Systems › Ducts
Issued 26 July 2005 Resolved
VESSELS FIRE DAMPERS ON O6 DECK WERE IMPROPERLY LABELED. VESSEL MUST MAKE PROPER LABEL CHANGES TO THIS EQUIPMENT.
Due 9 August 2005
Resolved 15 August 2005
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Location
Issued 26 July 2005 Resolved
THE VESSELS EMERGENCY SHUTDOWN FOR THE HIGH PRESSURE FOG SYSTEM GENERATOR WAS [name withheld] GENERATOR SHUTDOWN . VESSEL MUST MAKE PROPER LABEL CHANGES.
Action required: 705 - Other - as specified
Due 9 August 2005
Resolved 15 August 2005
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 26 July 2005 Resolved
VESSEL FUEL VENTS ON THE 08 DECK AFT OF STACK HAD NO FIXED CONTAINMENT. VESSEL MUST FABRICATE CONTAINMENT SYSTEM.
Condition: Unknown
Due 9 August 2005
Resolved 3 March 2006
Fire Fighting › Nozzles › Condition
Issued 26 July 2005 Resolved
VESSELS FIREFIGHTING STATION 1-10 HAD A FROZEN AND INOPERABLE NOZZLE. VESSEL MUST REPLACE THE NOZZLE.
Condition: Improper/Lack of Maintenance
Due 1 August 2005
Resolved 15 August 2005
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 26 July 2005 Resolved
DURING VESSELS LICENSING INSPECTION VARIOUS OPERATIONAL LICENSES WHERE MISSING FROM CREW PACKAGES. .
Due 26 July 2005
Resolved 26 July 2005
Resolution: VESSEL ADMINISTRATION REMEDIED ISSUES ON THE SPOT
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 10 June 2005 Resolved
Safety Management System is not implemented and maintained on a ship-based level for the machinery and electrical systems. Perform an external audit of the Safety Management System specifically establishing the reliability of the machinery and electrical systems.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 June 2005
Resolved 27 July 2005
Operations/Management › Navigation Safety › Doors Closed at Sea
Issued 10 June 2005 Resolved
WTD 5 AND 6 WAS FOUND WEDGED OPEN WITH 2"x4"S DURING INSPECTION QUESTIONED CREW REVEALED THAT DOOR IS MAINTAINED WEDGED OPEN AT ALL TIMES INCLUDING DURING THE TIMES OF NAVIGATION
Action required: 17 - Rectify deficiencies prior to departure
Due 10 June 2005
Resolved 12 June 2005
Lifesaving › Emergency Outfit › Breathing Apparatus
Issued 10 June 2005 Resolved
Provide two missing emergency escape breathing device on deck six as required by the fire control plan
Action required: 17 - Rectify deficiencies prior to departure
Due 10 June 2005
Resolved 11 June 2005
Operations/Management › Navigation Safety › Doors Closed at Sea
Issued 10 June 2005 Resolved
WTD 11 WAS FOUND WEDGED OPEN DURING INSPECTION QUESTIONED CREW REVEALED THAT DOOR IS MAINTAINED WEDGED OPEN WITH ANGLE IRON AT ALL TIMES INCLUDING DURING THE TIMES OF NAVIGATION
Action required: 17 - Rectify deficiencies prior to departure
Due 10 June 2005
Resolved 12 June 2005
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 10 June 2005 Resolved
REMOVE EXCESS OIL FOUND IN BILGE
Action required: 17 - Rectify deficiencies prior to departure
Due 10 June 2005
Resolved 12 June 2005
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 10 June 2005 Resolved
Verify that appropriate corrective action has been taken to ensure the proper operation of the controllable pitch propeller system.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 June 2005
Resolved 11 June 2005
Engineering › Generator (propulsion-electric) › Bus
Issued 10 June 2005 Resolved
Ensure that a self-contained emergency source of electrical power is available to supply all of those services that are necessary for the safety of the passengers and the crew in an emergency
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2005
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 21 April 2005 Resolved
Vessel can not provide transfer procedures that meet the requirments of 33 CFR 155.750. Vessel must provide procedures before tanking on fuel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2005
Resolved 27 July 2005
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 21 April 2005 No resolution recorded
E/R is missing procedures to identify describe and respond to potential emergency shipboard situations. Vessel must provided procedures as per ISM Code 7 and 8.
Action required: 15 - Rectify deficiencies by next port
Construction/Loadline › Structures › Door
Issued 21 April 2005 Resolved
WTD #5 local control does not reset to remote operation position after local use. If not corrected prior to sailing a crew member must be provided to operate this door manually in case of an emergency.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 April 2005
Resolved 27 July 2005
Lifesaving › Launching Appliances › Winch Brake
Issued 1 February 2005 Resolved
Have Class attest to proper operation of the #1 Boat davit, the brakes did not work when boat was lowered and have Flag/Class address max # of passengers after removing Boat #1 and Boat #2 From Service Prior to Sailing.
Action required: 705 - Other - as specified
Due 16 February 2005
Resolved 1 February 2005
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 1 February 2005 Resolved
Class to examine and provide evaluation of and determination on doors from 5th deck leading out of aft port and starboard stair towers. Doors are on announciator panel as fire screen doors but have glass in them and lock so that passengers can not escape from stairtower.
Action required: 705 - Other - as specified
Due 1 March 2005
Resolved 28 April 2005
Lifesaving › Inflatable Liferafts › Container Marking
Issued 1 February 2005 Resolved
Provide cover for training davit launched liferaft so that it is not confused with an operable raft.
Due 15 February 2005
Resolved 28 April 2005
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 25 January 2005 Resolved
MASTER/FIRE FIGHTING CREW DOES NOT HAVE ACCESS TO ALL SPACES ONBOARD THE VESSEL. CASINO AREAS ARE LOCKED AND INACCESSABLE IN THE EVENT OF AN EMERGENCY.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2005
Resolved 1 February 2005
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 25 January 2005 Resolved
Fire screen door announciator panel on bridge indicated 11 of 54 doors did not close upon automatic release as required by SOLAS Ch.II-2, Reg. 30.4. Vessel to repair and provide class report prior to verification by Coast Guard and carriage of passengers.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2005
Resolved 1 February 2005
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 25 January 2005 Resolved
PROVIDE ADEQUATE EXTERIOR VENTILATION FOR CLOTHES DRYER IN LAUNDRY SPACE TO SATISFACTION OF FLAG; ILO 147 CREW ACCOMIDATION #24
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2005
Resolved 1 February 2005
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 25 January 2005 Resolved
Repair latch for fire door location Frame 134, Deck 3 Port Side as required by SOLAS 74, Ch. II-2, Reg. 23(d). Repair prior to sail.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2005
Resolved 27 January 2005
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 25 January 2005 Resolved
Provide latching device for fire screen door to AHU room, port side, Deck 4, Frame 57 as required by SOLAS 74, Ch. II-2, Reg. 23(d). Correct prior to sail.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2005
Resolved 1 February 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 25 January 2005 Resolved
Remove excessive rags and cardboard from galley and passageway as required by ILO-147 Accident Prevention 3(a). Correct prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2005
Resolved 1 February 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 25 January 2005 Resolved
PROVIDE POSTED CO2 INTRUCTIONS AT LOCAL CONTROL STATION IN ENGINE ROOM; FSS CODE CH 5 2.1.3.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2005
Resolved 1 February 2005
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 25 January 2005 Resolved
REPAIR DOOR HANDLE FOR FIRE DOOR PORTSIDE DECK 2 FRAME 95
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2005
Resolved 1 February 2005
Fire Fighting › Means of Escape › Escape Route Signs
Issued 25 January 2005 Resolved
Remove signage "Do Not Open" from exterior Exit Door Port Side Aft, Deck 6 Inside and Outside as required by SOLAS Ch. II-2, Reg. 13.3.2.5 prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2005
Resolved 1 February 2005
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 25 January 2005 Resolved
SOLAS II-2 Reg 10 requires two spare charges for each fireman's outfit. The vessel only has 12 spare bottles onboard vice 24. Provide 12 spare charges prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2005
Resolved 25 January 2005
Navigation › Collision/Grounding Avoidance › Radar
Issued 20 January 2005 Resolved
SECOND MARINE RADAR NOT FUNCTIONING PROPERLY
Due 9 February 2005
Resolved 27 January 2005
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 18 January 2005 Resolved
Excessive oil is present in engineroom and purifier room bilges. Remove oil and clean bilges prior to sailing
Action required: 705 - Other - as specified
Due 15 February 2005
Resolved 8 February 2005
Personnel › Training › Watchkeeping
Issued 18 January 2005 Resolved
Provide marine crew billet structure and training prior to sailing. Document Marine Crew familiarization - new billet structure
Action required: 17 - Rectify deficiencies prior to departure
Due 18 January 2005
Resolved 8 February 2005
Construction/Loadline › Structures › Door
Issued 18 January 2005 Resolved
Water Tight Door #10 was found disabled with a wire tie so that the door would not remotely close. Safety Officer to ensure this process is corrected.
Due 18 January 2005
Resolved 18 January 2005
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 18 January 2005 Resolved
Confirm fire alarm panel operations identified from CG witnessed drill on Jan 18, 2005. Prove proper operation of fire alarm panel on the bridge
Due 25 January 2005
Resolved 1 February 2005
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 18 January 2005 Resolved
Identify primary billets on the muster list and assign alternate personnel that when crew members are absent backups are present to assume the critical duties. Correct muster list to provide back-up personnel for critical billets
Due 25 January 2005
Resolved 8 February 2005
Fire Fighting › Means of Escape › Escape Route Signs
Issued 18 January 2005 Resolved
Safety Officer confirm all emergency evacuation arrows throughout the ship match emergency evacuation plan primary and secondary evacuation routes. To be reinspected at next Coast Guard visit
Due 15 February 2005
Resolved 28 April 2005
Navigation › Collision/Grounding Avoidance › Radar
Issued 18 January 2005 Resolved
10cm radar is does not operate. Repair inoperable radar
Due 9 February 2005
Resolved 27 January 2005
Operations/Management › Port and Waterways Safety › Notice of Hazardous Condition
Issued 18 January 2005 Resolved
Vessel did not submit Letter Of Deviation application for the inoperable 10cm radar. Provide request for and receive LOD prior to sailing.
Due 18 January 2005
Resolved 19 January 2005
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 18 January 2005 Resolved
Exposed wires on the bridge and in the engine room. Properly terminate or remove exposed wiring
Due 15 February 2005
Resolved 8 February 2005
Fire Fighting › Means of Escape › Blocked
Issued 18 January 2005 Resolved
Escape route out of Aft Ro-Ro deck Port side goes to a storage room that is not a clear passage Remove obstructions and provide a clear path for egress
Due 25 January 2005
Resolved 25 January 2005
Engineering › Fuel Oil Service System › Filter
Issued 18 January 2005 Resolved
Fuel Oil Purifier excessively leaking fuel vapors Identify and correct excessive oil leakage
Due 1 February 2005
Resolved 8 February 2005
Fire Fighting › Structural - A Class Divisions › Doors
Issued 18 January 2005 Resolved
Deck 3-Aft Portside Door #56, class A-60, found with no gasket and three holes in door Install new gasket and door to the satisfaction of class
Due 25 January 2005
Resolved 28 April 2005
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 18 January 2005 Resolved
Deck 2 Water Tight Door #65 was not manned IAW the vessel’s muster list during “soft crew” muster drill. Correct prior to carriage of passengers
Due 18 January 2005
Resolved 8 February 2005
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 18 January 2005 Resolved
Deck 3, Exit Door Walkway, Port Side was not manned IAW the vessel’s muster list during “soft crew” muster drill. Correct prior to carriage of passengers
Due 18 January 2005
Resolved 8 February 2005
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 18 January 2005 Resolved
Deck 4, starboard side aft stair tower was not manned IAW the vessel’s muster list during “soft crew” muster drill. Correct prior to carriage of passengers
Due 18 January 2005
Resolved 8 February 2005
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 18 January 2005 Resolved
Deck 5, aft lounge and deck aft of lounge were not manned IAW the vessel’s muster list during “soft crew” muster drill. Correct prior to carriage of passengers
Due 18 January 2005
Resolved 8 February 2005
Personnel › Training › Familiarization Training
Issued 18 January 2005 Resolved
IAW the vessel’s Personnel and Training Manual Chapter 4.02, familiarization tour is not documented for personnel on the muster list prior to being assigned shipboard duties. Complete checklist 4.2g IAW the vessel’s Personnel and Training Manual and provide evidence of crew familiarization
Due 1 February 2005
Resolved 8 February 2005
Personnel › Manning/Qualifications › Qualified Individual (VRP)
Issued 18 January 2005 Resolved
· The vessel’s Chief Engineer was unable to perform the duties as a Chief Engineer aboard the vessel. He was unable to communicate in the language of the crew, English, as he only spoke Spanish. Additionally he was unaware of his assigned duties during an emergency and did not follow the vessel’s Emergency Response Manual for the procedures relating to a steering failure. · The vessel’s Second
Due 25 February 2005
Resolved 28 April 2005
Fire Fighting › Combustible Materials › Matresses
Issued 18 January 2005 Resolved
Remove excessive rags and cardboard from galley and passageway prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 January 2005
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 18 January 2005 Resolved
Examine and verify proper operation of fire door indicator panel status for deck 5 aft stairwell sliding doors (indicator to be removed from panel if these are not fire doors)
Action required: 705 - Other - as specified
Due 3 February 2005
Resolved 8 February 2005
Fire Fighting › Combustible Materials › Facings/Mouldings/Decorations/Veneers
Issued 18 January 2005 Resolved
Perform general housekeeping of storage spaces and service spaces - excessive combustibles ILO 147 ACCIDENT PREVENTION 3(a)
Due 8 February 2005
Resolved 8 February 2005
Personnel › Manning/Qualifications › Qualified Individual (VRP)
Issued 18 January 2005 Resolved
Chief Engineer and Second Engineer were not able to communicate effectively in the English language with the crew during emergency drills
Action required: 705 - Other - as specified
Due 3 February 2005
Resolved 27 January 2005
Fire Fighting › Structural - B Class Divisions › Doors
Issued 18 January 2005 Resolved
Ensure that deck 7 stairwell stbd side B-15 antrance door to elevator closes properly - hits frame
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 February 2005
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 18 January 2005 Resolved
Remove all plastic trash cans - must be non-combustibleSOLAS 2004 CH II-2 REG 4 - 4.2
Due 1 February 2005
Resolved 1 February 2005
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 18 January 2005 Resolved
Label all fire screen doors in accordance with Fire Control Plan SOLAS 2004 CH II-2 REG 15 - 2.4
Action required: 705 - Other - as specified
Due 1 March 2005
Resolved 21 April 2005
Fire Fighting › Structural - B Class Divisions › Doors
Issued 18 January 2005 Resolved
deck 7 to starirwell Stbd side B-15 antrance door to elevator - install exit sign on inside of door
Action required: 705 - Other - as specified
Due 3 February 2005
Resolved 1 February 2005
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 18 January 2005 Resolved
Provide written status of all previously issued deficiencies and locate all associated paperwork required by outstanding deficiencies.
Due 1 February 2005
Resolved 1 February 2005
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 18 January 2005 Resolved
deck 7 aft frame 57 - identify all tank vents and install proper size oil containment.
Due 24 February 2005
Resolved 28 April 2005
Communications › Audible Communications › Bell
Issued 18 January 2005 Resolved
The public address speaker outside the security office on deck 5 was found disabled. SOLAS 04 Ch IIII, Reg 6.5.5
Due 25 January 2005
Resolved 25 January 2005
Documentation › Logs/Records › Logbook (official)
Issued 18 January 2005 Resolved
Participation in crew drills is not documented SOLAS Ch III, Reg 30
Due 25 January 2005
Resolved 25 January 2005
Fire Fighting › Self-contained Breathing Apparatus › Air Supply (minutes)
Issued 18 January 2005 Resolved
Three EEBD's in engine room were discharged
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 January 2005
Documentation › Logs/Records › Logbook (official)
Issued 18 January 2005 Resolved
SOLAS lifesaving familiarization manual is missing chapters 3.03, 3.04 & 4SOLAS Ch III, Reg 35
Due 25 February 2005
Resolved 21 April 2005
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 18 January 2005 Resolved
essel’s muster list does not match the issued crew duty cards, muster list has been modified since its approval SOLAS 04 Ch III, Reg 8
Due 1 February 2005
Resolved 8 February 2005
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Pressure
Issued 18 January 2005 Resolved
B-V EXTINGUISHER IN ENGINE ROOM WAS DISCHARGED
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 January 2005
Fire Fighting › Means of Escape › Blocked
Issued 18 January 2005 Resolved
PASSENGER ELEVATOR DOESNOT HAVE MEANS OF ESCAPE
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 January 2005
Operations/Management › Drills/Instruction › Safety Orientation
Issued 18 January 2005 Resolved
Deck 5 Restaurant aft blkhd - Provide other half of passenger orientation sign. solas 04 ch III/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 18 January 2005 Resolved
Deck 5 mid-ship fan room - perform housekeeping and identify status of two portable fire extinguishers lying on the deck.???ILO? ILO 147 ACCIDENT PREVENTION 3(a)
Due 1 February 2005
Resolved 1 February 2005
Documentation › Markings/Placards › Warning Signs
Issued 18 January 2005 No resolution recorded
PROVIDE ENGLISH TRANSLATION FOR ALL ENGINE ROOM EQUIMPMENT
Action required: 15 - Rectify deficiencies by next port
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 18 January 2005 Resolved
Deck 5 Aft Stage - backroom - ceiling light hanging by wire and housekeeping.ILO 147 ACCIDENT PREVENTION 3(a)
Due 1 February 2005
Resolved 1 February 2005
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 18 January 2005 Resolved
Station Billet - identify duplicate crew cards, crew must remain in emergency bill position until abandonship signal sounded, back-up person required for critical positions (i.e. #67 missing on 1/25/05). solas 04 ch III/8
Due 1 February 2005
Resolved 8 February 2005
Documentation › Markings/Placards › Warning Signs
Issued 18 January 2005 Resolved
PROVIDE ENGLISH TRANSLATION FOR RED VALVE IN AREA AFT OF GALLEY OUTSIDE THE TWO HEADS INSIDE ROOM 3333A
Action required: 705 - Other - as specified
Due 3 February 2005
Resolved 1 February 2005
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 18 January 2005 Resolved
Deck 5 aft deck - Provide Muster Station "A" signs and arrows in vicinity of ladder to Deck 6 when exiting theatre. solas 04 ch III/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2005
Documentation › Markings/Placards › Warning Signs
Issued 18 January 2005 No resolution recorded
PROVIDE ENGLISH TRANSLATION FOR ALL ELECTRICAL PANELS AND OTHER INSTRUCTIONS FOR ELECTRICAL SWITCHES
Action required: 15 - Rectify deficiencies by next port
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 18 January 2005 Resolved
Deck 5 aft stbd stairwell Frame 20 - remove items from compartment and seal door shut. ILO ACCIDENT PREVENTION 3(a)
Due 8 February 2005
Resolved 8 February 2005
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 18 January 2005 Resolved
REMOVE ALL PLASTIC TRASH CANS - MUST BE NONCOMBUSTABLE
Action required: 705 - Other - as specified
Due 8 February 2005
Resolved 8 February 2005
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 18 January 2005 Resolved
Deck 5 aft port AC Vent Room - provide light cover. SOLAS 2004 II-1 REG 45 1.3
Due 25 February 2005
Resolved 28 April 2005
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 18 January 2005 Resolved
LIGHT COVERS ARE MISSING THROUGHT ENGINE ROOM AND AUX ENGINE ROOMS
Action required: 705 - Other - as specified
Due 24 February 2005
Resolved 21 April 2005
Fire Fighting › Structural - A Class Divisions › Doors
Issued 18 January 2005 Resolved
Deck 2 Port side Frame 56 - fire door into fire equipment stowage latch inoperative. solas 04 ch II/9.4.1.1.1
Due 1 February 2005
Resolved 1 February 2005
Communications › Alarms/Indicators › General Alarm
Issued 18 January 2005 Resolved
ALARMS ARE NOT CLEARLY AUDIBLE IN THE ENGINE ROOM
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 January 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 18 January 2005 Resolved
Deck 2 Stbd Aft Frame 18 - Provide storage racks or remove 8 oxygen and 4 acetylene cylinders 46 CFR 147.60(b
Due 1 February 2005
Resolved 1 February 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 18 January 2005 Resolved
Deck 2 Aft Ventilation area compartments Frames 0-19 - General Housekeeping ILO 147 ACCIDENT PREVENTION 3(a)
Due 1 February 2005
Resolved 1 February 2005
Fire Fighting › Ventilation Systems › Operating Controls
Issued 18 January 2005 Resolved
Deck 1 Laundry - Provide written company policy for cleaning and maintaining dry ventilation preventative maintenance to prevent fire. ism code part A section 10
Due 8 February 2005
Resolved 8 February 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 18 January 2005 Resolved
Deck 2 laundry - Provide proper stowage of two cylinders in old head. 46 CFR 147.60(b)
Due 1 February 2005
Resolved 1 February 2005
Fire Fighting › Means of Escape › Blocked
Issued 18 January 2005 Resolved
Deck 2 Stbd stairwell next to elevator clean all stowage out of locker. ILO 147 ACCIDENT PREVENTION 3(a)
Due 1 February 2005
Resolved 1 February 2005
Fire Fighting › Means of Escape › Blocked
Issued 18 January 2005 Resolved
Deck 2 Stbd Forward frame 110 interior passageway - clear all equipment stowed on deck inhibiting emergency egress. ILO 147 ACCIDENT PREVENTION 3(a)
Due 1 February 2005
Resolved 1 February 2005
Fire Fighting › Nozzles › Condition
Issued 18 January 2005 Resolved
Deck 1 forward - Fire nozzle FH 1-8 frozen (where the fire drill was held on 1/25/05). SOLAS 2001 II-2 REG 21
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 January 2005
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 18 January 2005 Resolved
Deck 2 laundry Frame 68 - Close open wiring for light switch.SOLAS 2004 II-1 REG 45 1.3
Due 1 February 2005
Resolved 1 February 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 18 January 2005 Resolved
Access accumulation of waste oil in bilges due to excessive leaking of machinery and piping throughout engineering ILO-147
Due 8 February 2005
Resolved 8 February 2005
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 18 January 2005 Resolved
Crewman, badge #27, was missing during the “soft crew” drill. The location on muster list was not descriptive of the actual location in that the list stated “Main Stair Tower Leading Down” at that location, the main stair tower does not lead down. SOLAS 04 Ch III, Reg 37
Due 1 February 2005
Resolved 8 February 2005
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 18 January 2005 Resolved
DURING OPERATION OF THE OWS, WHEN THE ACTIVATING, VALVE CHANGES POSITION IT CAUSES THE SYSTEM TO OVER PRESSURE AND BLOW OILY WATER OUT THE PUMP SEAL. MARPOL 73/78 REG. 16
Due 8 February 2005
Resolved 8 February 2005
Fire Fighting › Structural - Horizontal Zones › General
Issued 18 January 2005 Resolved
DECK 4 AFT CASINO FR 30-50 PORT & STBD SEAL 1/4" HOLES IN WINDOW FRAMES. WINDOW 5 AND 6 STBD, 6 PORT
Due 3 February 2005
Resolved 1 February 2005
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 18 January 2005 Resolved
THE HAND RAIL IN THE FWD STAIRWELL LEADING TO THE FWD SEWAGE ROOM HAS RIPPED OFF THE WALL, AND HANGING FREELY. ILO 147
Due 8 February 2005
Resolved 8 February 2005
Fire Fighting › Structural - Horizontal Zones › General
Issued 18 January 2005 Resolved
DECK 4 STBD AFT STAIRWELL FR 27 - WINDOW 1/4" HOLES IN WINDOW FRAME
Due 3 February 2005
Resolved 1 February 2005
Documentation › Markings/Placards › Warning Signs
Issued 18 January 2005 Resolved
DECK 4 AFT ENTRANCE INTO MUSTER STATION B ADD SIGNAHE ON BULKHEAD OUTSIDE ENTRANCE
Due 3 February 2005
Resolved 1 February 2005
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 18 January 2005 Resolved
THE MIDDLE AND FWD SEWAGE TANKS WERE IN AN OPEN CONDITION ( ACCESS PLATES AND PIPES REMOVED) ALLOWING SEWAGE TO SPILL INTO THE BILGE CAUSING AN UNHEALTHY ENVIROMENT. ILO147
Due 27 January 2005
Resolved 27 January 2005
Fire Fighting › Combustible Materials › Matresses
Issued 18 January 2005 Resolved
DECK 4 CASINO PORT FORWARD FRAME 137- REMOVE STOWAGE IN OPEN COMPARTMENT
Due 3 February 2005
Resolved 1 February 2005
Fire Fighting › Fire Hydrants › Location/Position
Issued 18 January 2005 Resolved
DECK 3 FRAME 134 STBD FIRE HYDRANT FH 3-2 - TURN VALVE SO HOSE IS NOT KINKED
Due 8 February 2005
Resolved 8 February 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 January 2005 Resolved
OPEN PIPING IN ROOM 7808B ON 01 DECK IS EMITTING SEWAGE ODORS. ILO 147
Due 1 February 2005
Resolved 1 February 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 18 January 2005 Resolved
DECK 3 FRAME 134 STBD SIDE STORAGE LOCKER - REMOVE EXCESSIVE AMOUNT OF EMPTY CARDBOARD BOXES
Due 3 February 2005
Resolved 8 February 2005
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 18 January 2005 Resolved
LIFE RAFT HYDROSTATIC RELEASES DO NOT HAVE EXP. DATES INDICATED. SOLAS 74 CH. III REG 19
Due 1 February 2005
Resolved 8 February 2005
Lifesaving › Lifeboat Equipment › Pump (manual)
Issued 18 January 2005 Resolved
LIFEBOAT NO.2 BILGE PUMP HANDLE IS BROKEN. SOLAS 74 CHIII REG41
Due 1 February 2005
Resolved 1 February 2005
Fire Fighting › Means of Escape › Doorways
Issued 18 January 2005 Resolved
DECK 3 ESCAPE SCUTTLES - PROVIDE 'T' HANDLES AT EACH AND CUT CARPETS TO EXPOSE LOCKING BOLT
Action required: 705 - Other - as specified
Due 3 February 2005
Resolved 8 February 2005
Documentation › Markings/Placards › Warning Signs
Issued 18 January 2005 Resolved
LIFE JACKET STOWADE IS NOT MARKED WITH INTL' SYMBOLOGY ON SEVERAL OF THE CONTAINERS
Due 24 February 2005
Resolved 28 April 2005
Lifesaving › Lifeboat › Seating
Issued 18 January 2005 Resolved
LIFEBOATS NO. 2 & 3 HAVE OBSTRUCTED SEATING ARRANGEMENTS DUE TO INSTALLATION OF STARTING BATTERIES THAT LIMIT AVAILIABLE SEATING. SOLAS 74 CH. III REG 41
Due 1 February 2005
Resolved 1 February 2005
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 18 January 2005 Resolved
Conduct an external ISM audit of the vessel’s safety management system prior to departure. Based on observations aboard the vessel the following non-conformities were observed: · Marine crew did not have duties defined on a muster list for operations when the “soft crew” was not onboard · Duties listed on the vessel’s muster list did not match the issued crew duty cards. Muster list has been
Due 25 February 2005
Resolved 28 April 2005
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 18 January 2005 Resolved
PASSENGER STATE ROOMS 2215, 2216, 1133 AND 1130 ARE MISSING LIGHT COVERS AND HAVE EXPOSED UNPROTECTED WIRING IN THE OVERHEAD
Due 8 February 2005
Resolved 8 February 2005
Communications › Radio Communications › Emergency Source of Power
Issued 18 January 2005 Resolved
PERFORM REQUIRED MAINTAINENCE ON EMERGENCY BATTERIES FOR RADIOS. BATTERIES WERE FOUND LOW OF ELECTROLYTE. SOLAS 74 CH. IV/ REG 13
Due 25 January 2005
Resolved 25 January 2005
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 18 January 2005 Resolved
PROVIDE SPECIFIC DUTIES ON THE MUSTER LIST FOR PROVIDING sSART'S TO THE LIFEBOATS
Due 3 February 2005
Resolved 8 February 2005
Navigation › Piloting/Steering › Marine Charts
Issued 18 January 2005 Resolved
PROVIDE ADMIRAILTY CHART UPDATE PUBLICATION. 33CFR 164.72
Due 1 February 2005
Resolved 1 February 2005
Documentation › Logs/Records › Logbook (official)
Issued 18 January 2005 Resolved
PROVIDE UPDATED SOLAS TRAINING MANUALS FOR SOFT CREW AND ENSURE AVAILABILITY IN CREW AREAS
Due 10 February 2005
Resolved 1 February 2005
Engineering › Fuel Oil Service System › Hose
Issued 18 January 2005 Resolved
PROVIDE BACKPRESSURE NOZZLE FOR EXTRA GENERATOR FUEL HOSE AND PROVIDE PERMANET CONTAINMENT OF 1 BARREL
Due 3 February 2005
Resolved 1 February 2005
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 18 January 2005 Resolved
INITIATE NON-CONFORMITIES FOR THE FOLLOWING ITEM: GENERAL ALARM SYSTEM PROCEDURES FOR KLAXON AND PUBLIC ANNOUNCEMENT UPDATING OF MAINTAINCE RECORDS ERROR IN NO. 2 GYRO REPEATER PROCEDURES FOR PUMPING BILGES- CURRENTLY SEWAGE TANK ARE BEING USED FOR BILGE WASTE DISPOSAL. ISM CODE PART A-9
Due 1 February 2005
Resolved 1 February 2005
Electrical › Electric Generation Source (service) › Generator
Issued 17 December 2004 Resolved
Provide class report atesting to permanent repairs complete on DG-5. - Maintain live watch on mobile 1500 KW generator located on deck 8 when operating.
Condition: Design Flaw
Due 1 March 2005
Resolved 28 April 2005
Operations/Management › Drills/Instruction › Abandon Ship
Issued 17 December 2004 Resolved
PRIOR TO REDUCTION OF SOFT CREW FROM FULL EMERGENCY STATION BILL WHEN MAIN CASINO IS USED EXCLUSIVELY, PROVIDE CLASS ACCEPTANCE OF PROPOSAL AND UPDATES OF ALL ASSOCIATED DOCUMENTS, PUBS AND FORMS. DEMONSTRATE ADEQUATE REDUCED EMERGENCY STATION BILL IN THE PRESENCE OF A CG MARINE INSPECTOR.
Due 21 April 2005
Resolved 8 February 2005
Resolution: Vessel''s marine manager [name withheld] has decided not to operate the vessel without all soft crew aboard.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 21 October 2004 Resolved
Provide type approved double leaf fire doors and ensure that those fire doors installed in main vertical zone bulkheads and stairway enclosures comply with SOLAS II-2/30. Classification Society must issue a condition of class specifying any interim operational measures and timeline to be completed.
Condition: Improper Installation
Due 21 November 2004
Resolved 25 January 2005
Construction/Loadline › Structures › Trunk
Issued 21 October 2004 Resolved
Provide a passenger means of escape from the starboard side forward balcony on deck 3 that is not a vertical escape ladder through a scuttle in the deck above. SOLAS II-2/28. Classification Society must issue a condition of class specifying any interim operational measures and timeline to be completed.
Condition: Improper Installation
Due 1 March 2005
Resolved 21 April 2005
Resolution: Area has been taken out of passenger access
Construction/Loadline › Structures › Scuttle
Issued 21 October 2004 Resolved
Ensure that escape hatches in a means of escape are capable of being operated from each side. SOLAS II-2/28. Classification Society must issue a condition of class specifying any interim operational measures and timeline to be completed.
Condition: Placed in Improper Service
Due 21 November 2004
Resolved 25 January 2005
Lifesaving › Lifeboat › Capacity
Issued 21 October 2004 Resolved
Provide written Flag Administration acceptance of non-lifeboatman certificated individuals to serve as PIC of survival craft (liferafts) after being specially trained. Provide Flag Administration acceptance of current liferaft/survival training course as meeting this training. SOLAS III/10.4.
Due 24 February 2005
Resolved 21 April 2005
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 21 October 2004 Resolved
Provide SOLAS Training Manual Updates for each manual and provide current copy of manual in crew mess room per SOLAS III/35: A. Rescue boat recovery info placed in manual. B. Place udated Muster List in manual.
Condition: Unknown
Due 8 February 2005
Resolved 8 February 2005
Construction/Loadline › Structures › Door
Issued 5 July 2004 No resolution recorded
Ensure all passenger means of escape, above the bulkhead deck, are independent of watertight doors. SOLAS II-2/28. Classification Society must issue a condition of class specifying any interim operational measures and timeline to be completed.
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Lifesaving › Lifeboat › Capacity
Issued 5 July 2004 Resolved
Provide written Flag Administration determination if second in command of lifeboats must be a certificated person per SOLAS III/10.4. Request written determination of the number of certificated lifeboatmen required for this vessel.
Condition: Unknown
Due 24 February 2005
Resolved 21 April 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 5 July 2004 Resolved
Class provide evaluation of adequacy of lifejacket stowage so their distribution and donning does not impede orderly movement to survival craft embarkation stations to include embarking MES from Assembly Station B per SOLAS III/22.2
Condition: Unknown
Due 1 March 2005
Resolved 28 April 2005
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 5 July 2004 Resolved
Provide class report for demonstration of ability to launch rescue boat with vessel making 5 kts per SOLAS III/17.3
Due 1 March 2005
Resolved 28 April 2005
Operations/Management › Drills/Instruction › Abandon Ship
Issued 5 July 2004 Resolved
Provide additional means of comms for Assembly “B” PIC in addition to or replacement for the bull horn to communicate with other Assembly "B" crewmembers and passengers.
Due 21 November 2004
Resolved 25 January 2005

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.