Records from 2004 to 2026. Most recent: inspection, 26 February 2026.
Inspection history · 34
26 February 2026
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8314248
16 October 2025
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8254012
3 October 2024
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8013568
5 December 2023
COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7826578
10 October 2023
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7806939
7 March 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7646751
5 October 2021
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7206506
30 September 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7272568
31 January 2021
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7141632
14 October 2020
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7054327
3 December 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6797438
1 October 2019
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6797426
10 December 2018
Annual Inspection · Administrative Inspection · DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6570898
2 March 2018
Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6373274
5 December 2017
Internal Structural Exam · Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6318535
21 February 2017
Deficiency Check · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6092091
23 March 2016
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5840050
19 January 2016
Annual Inspection · Administrative Inspection · Drydock Exam · DAPI Audit · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5814975
15 February 2012
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4245062
19 January 2012
Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4227677
25 March 2010
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3702469
18 January 2010
Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3665597
5 March 2009
COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3427912
7 February 2008
Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3143618
6 February 2007
Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2867686
2 August 2006
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2733733
6 April 2006
Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2616589
8 February 2006
Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2581004
12 May 2005
Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2355289
10 November 2004
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2238324
31 October 2004
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2238282
2 October 2004
Type not recorded
No type recorded · Station Key West · USCG Southeast District (CGD-SE) · Activity 2211762
2 October 2004
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2216384
24 March 2004
Initial Certification
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2028900
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 February 2026
Resolved
Mark the entranceway to the flying bridge with the maximum allowable passengers allowed on the upper deck in letters of at least 1" in height.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2026
Resolved 6 March 2026
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 February 2026
Resolved
Mark each life jacket stowage location with the type and number of life jackets stowed inside (25 adult life jackets, etc.) in letters and numbers of at least 2" in height.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2026
Resolved 6 March 2026
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 October 2023
Resolved
There is a quarter sized gouge in the starboard stem. Rebuild damaged area.
Action required: 705 - Other - as specified
Resolved 12 October 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 March 2023
Resolved
The Port engine room automatic submersible bilge pump is inoperable. Repair or replace prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2023
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 7 March 2023
Resolved
The visual indicator for the port high water alarm is inoperable. Repair or replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 March 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 March 2023
Resolved
Permanently mount the starboard engine room electronic submersible bilge pump float switch.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 March 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 October 2021
Resolved
Lower 2" of the port shaft tube has been damaged. Grind back and repair the port shaft tube to original dimensions and lay up prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 8 October 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 September 2021
Resolved
One of the life floats did not have the name of the vessel marked or painted on it. Clearly mark of paint the name of the vessel the life float.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 October 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 October 2020
Resolved
Vessel's starboard steering ram showed a small leak that was corrected by tightening a fitting on the ram.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2020
Resolved 15 October 2020
Resolution: Deficiency corrected on the spot.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 3 December 2019
Resolved
De-laminated fiberglass just aft of the strut. Submit repair proposal to local OCMI.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 20 December 2019
Resolution: REPAIRED HULL
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 October 2019
Resolved
Replace 18 Adult PFD's, PFD's were compressed between 25%-50% from the original thickness and would not return back to original size. Vessel is restricted to the carriage of 35 total persons.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 November 2019
Resolution: New PFDs onboard
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 1 October 2019
Resolved
Repair/replace portside fuel vent screen, screen must be of a corrosion resistant wire and at least 30x30 mesh.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 November 2019
Resolution: Vent replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 October 2019
Resolved
Repair rudder stops on both Port and STBD main steering gear, stops had been broken off at some point. Repair by credit drydock (31DEC2019).
Action required: 10 - Deficiency Rectified
Resolved 1 October 2019
Resolution: Vessel will install new stops at next credit DD/ISE (31DEC2019).
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 October 2019
Resolved
Make STBD fuel lines available for re-inspection, fuel lines found between fuel tank and engine room were corroded.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 November 2019
Resolution: Fuel lines cleaned and remain serviceable
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 December 2018
Resolved
Submit electrical plans to local OCMI for installed power inverter under operating station. Plans in the form of a elementary one-line diagram shall include wire size, length of run, rating of over-current protection (fuses/breakers). Vessel is restricted from using power inverter until plans have been approved and installation verified.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 April 2019
Resolution: Installation specifications received, installation meets ABYC/46 standards.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 10 December 2018
Resolved
Replace/repair magnetic compass light, light was not operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 December 2018
Resolution: Light is operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 December 2018
Resolved
Replace SOLAS tape on identified PFD's (10), tape was worn and would not be reflective.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 December 2018
Resolution: New SOLAS tape applied.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 2 March 2018
Resolved
Provide overcurrent device for inverter installed under console.
Action required: 705 - Other - as specified
Due 9 March 2018
Resolved 2 March 2018
Resolution: Installed overcurrent devices for inverter.
Documentation › Markings/Placards › Lifejacket Placard
Issued 2 March 2018
Resolved
Properly mark PFD stowage locations.
Action required: 705 - Other - as specified
Due 3 March 2018
Resolved 2 March 2018
Resolution: Marked stowage locations with size and amount.
Documentation › Markings/Placards › Lifejacket Placard
Issued 2 March 2018
Resolved
Post PFD donning placard.
Action required: 705 - Other - as specified
Due 3 March 2018
Resolved 2 March 2018
Resolution: Posted PFD placard.
Engineering › Fuel Oil Service System › Valve
Issued 2 March 2018
Resolved
Label fuel cut offs.
Action required: 705 - Other - as specified
Due 3 March 2018
Resolved 2 March 2018
Resolution: Labeled fuel cut offs
Documentation › Markings/Placards › Capacity Marking
Issued 2 March 2018
Resolved
Mark vessel with name and hailing port.
Action required: 705 - Other - as specified
Due 3 March 2018
Resolved 2 March 2018
Resolution: Marked hull with vessel name and hailing port.
Stability › Watertight Integrity › General
Issued 2 March 2018
Resolved
Repair handle on starboard watertight hatch.
Action required: 705 - Other - as specified
Due 3 March 2018
Resolved 2 March 2018
Resolution: Repaired handle
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 5 December 2017
Resolved
Renew flexible exhaust hose for starboard engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2018
Resolution: Vessel renewed hose with approved type.
Stability › Watertight Integrity › General
Issued 5 December 2017
Resolved
Renew/repair watertight hatch for the starboard forward compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2018
Resolution: Repaired hatch.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 21 February 2017
Resolved
Prove proper operation of port fireboy visual and audible alarms.
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 21 February 2017
Resolution: New fireboy indicator installed.
Communications › Alarms/Indicators › High Water Alarm
Issued 21 February 2017
Resolved
Each bilge high level alarm must have its own audible and visual indicator.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 31 March 2017
Resolution: High water indicators removed from spaces that were not required to have indicators, labeling no longer required. Four compartments had indicators, only 02 required due to hull penetrations.
Communications › Radio Communications › VHF Radiotelephone
Issued 21 February 2017
Resolved
Provide VHF radio with GPS unit.
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 11 April 2017
Resolution: GPS input installed in VHF radio.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 January 2016
Resolved
Light on second deck did not have cover, leaving bulb exposed and a safety hazard.
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 February 2016
Resolution: Missing cover was replaced.
Documentation › Markings/Placards › Garbage Placard
Issued 19 January 2016
Resolved
Waste management plan was not posted as required.
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 February 2016
Resolution: Placard was posted.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 19 January 2016
Resolved
COI and Stability letter were not posted as required.
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 16 February 2016
Resolution: COI and stability letter were posted.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 15 February 2012
Resolved
Re-label eleven adult PFDs.
Action required: 705 - Other - as specified
Due 20 February 2012
Resolved 15 February 2012
Resolution: PFDs labeled during the inspection.
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 February 2012
Resolved
Install hose clamp on portside intake hose.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 February 2012
Resolved 15 February 2012
Resolution: Hose clamp installed during the inpsection.
Lifesaving › Lifefloat › Painter
Issued 15 February 2012
Resolved
Make painter line on lifefloat float free.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 February 2012
Resolved 15 February 2012
Resolution: Painter line rectified to be float free.
Documentation › Certificates/Documents › Stability Letter
Issued 15 February 2012
Resolved
Post 2012 stability letter.
Action required: 705 - Other - as specified
Due 20 February 2012
Resolved 15 February 2012
Resolution: Stability letter posted during inspection.
Communications › Visual Communication › Warning Sign (gangway)
Issued 15 February 2012
Resolved
Post maximum capacity placard for the fly bridge.
Action required: 705 - Other - as specified
Due 20 February 2012
Resolved 15 February 2012
Resolution: Maximum capacity labeled during the inspection.
Lifesaving › Hand Flares › Expired
Issued 15 February 2012
Resolved
Acquire 02 red hand flares.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 February 2012
Resolved 15 February 2012
Resolution: 02 red hand flares acquired during the inspection.
Communications › Visual Communication › Warning Sign (radio room)
Issued 15 February 2012
Resolved
Fill in emergency broadcast placard with vessel particulars.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 February 2012
Resolved 15 February 2012
Resolution: Broadcast placard filled in during the inspection.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 15 February 2012
Resolved
Fireboy overide system including alarm panel must be fully operational.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 February 2012
Resolved 15 February 2012
Resolution: Overide system fixed during the inspection.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 25 March 2010
Resolved
Missing Lifesaving Equipment Maintenance Log.
Condition: Improper/Lack of Maintenance
Due 1 April 2010
Resolved 31 March 2010
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 March 2010
Resolved
COI and Stability letter not posted in conspicuous space at operating station.
Condition: Improper Installation
Due 1 April 2010
Resolved 31 March 2010
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 25 March 2010
Resolved
Missing portable light near machinery space (engine room).
Condition: Improper Installation
Due 1 April 2010
Resolved 31 March 2010
Stability › Watertight Integrity › General
Issued 25 March 2010
Resolved
Missing two locking devices on two engine room hatches.
Condition: Improper Installation
Due 1 April 2010
Resolved 31 March 2010