Inspection history · 23
7 December 2023
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7836226
6 December 2023
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7847128
30 October 2023
Administrative Inspection · PSC B · COC-TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7815376
23 June 2023
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7721879
21 May 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7693083
15 December 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7609597
4 November 2022
PSC B · COC-TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7588133
21 September 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7563653
1 November 2021
COC-TVE Renew · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7338489
1 June 2021
PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7211081
12 January 2021
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7123040
3 November 2020
COC-CHEM & TVE Annual · MARPOL Annex VI Survey · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7088707
1 June 2020
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6965587
27 October 2019
ISPS II Exam · COC-TVE Renew · Deficiency Check · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6840288
15 June 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6714535
9 November 2018
ISPS II Exam · Ballast Water Examination · COC-TVE Annual · COE-Dockside
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6577202
5 November 2018
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6574693
16 December 2017
COE-Dockside
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6325048
15 October 2017
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6282683
16 May 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6154407
14 July 2016
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5940671
11 June 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5907505
30 May 2016
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5885490
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 December 2023
No resolution recorded
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
PSCO observed pinhole leak on port side bunker piping near superstructure that resulted in approximately 1 gallon spilled into ship channel. Port side bunker pipe shall be isolated and not used until repairs are complete.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2023 — due date passed with no resolution recorded
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 October 2023
Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect i.e. assigned principally to accumulate batteries, in paint lockers, acetylene stores, or similar spaces unless Administration is satisfied that the equipment is (.4) appropriately certifified for safe usage in the dust, vapors, or gases likely to be encountered.
PSCO observed 03 light fixtures inside cargo pump room having cracked lenses and missing electrical bonding straps.
Action required: 15 - Rectify deficiencies by next port
Resolved 7 November 2023
Resolution: Received satisfactory rectification statement from L/R: Statement no: 2220850/01.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 30 October 2023
Resolved
The venting system shall be provided with devices to prevent the pasage of flames into cargo tanks.
PSCO found 02 flame screens on #2 and #5 Port cargo tank p/v valves to have quarter-sized holes in screen.
Action required: 15 - Rectify deficiencies by next port
Resolved 7 November 2023
Resolution: Received satisfactory rectification statement from L/R: Statement no: 2220850/01.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 30 October 2023
Resolved
Doors required to be self-closing shall not be fitted with holdback hooks.
PSCO ovserved manual holdback on self-closing door for CCR.
Action required: 10 - Deficiency Rectified
Resolved 30 October 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 November 2022
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed hydraulic leak at each side of steering gear ram leaking at a rate of one drop per second during operational testing.
SOLAS 74(a), 2011 cons., II-1/26.1
60ac
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 4 November 2022
Resolved 5 November 2022
Resolution: Recieved, reviewed, and accepted class report from [name withheld] stating forward port/stbd ram hydraulic seals were replaced. Operational test sat.
14 - Pollution Prevention › 141 - MARPOL Annex I › Cow operations and equipment manual
Issued 4 November 2022
Resolved
For oil cargo residue control, at least 25 percent of the cargo tanks are crude oil washed before each ballast voyage and that each cargo tank is crude oil washed at least once every fourth time crude oil is discharged from the tank, but no tank need be crude oil washed more than once during each 120 day period. PSCO observed vessel has not conducted crude oil washing despite carrying crude oil onboard as recorded in vessel oil record book part II. Request clarification from class.
33CFR157.160(a)(2)
50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 December 2022
Resolved 15 December 2022
Resolution: Sector Miami received clearification letter from class resolving the code 50 def.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 October 2019
Resolved
In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with the standards not inferior to those acceptable to the organization. 74 SOLAS (04) II-1/45.11
Multiple explosion proof electrical fittings in the cargo pump room and on deck missing cable glands allowing cable to move freely. This compromises the maximum expirimental safe gap requirements of the fitting.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2019
Resolved 29 October 2019
Resolution: Recieved classification report attesting to the rectification of all faulty electrical instalations in the pump room and on deck.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 27 October 2019
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company[10.1]. In meeting these requirements, the company should ensure that, inspections are held at appropriate intervals[10.2.1], any non-conformities are reported, with possible cause if known[10.2.2], and appropriate corrective action taken[10.2.3]. 74 SOLAS (14) IX/3.1 / ISM Code 10.1, 10.2
In accordance with fleet manual four electrical testing form E1-03, installations are to be inspected monthly. In accordance with fleet manual UMS checklist form 3.17, UMS engineering rounds are to be conducted daily.
As delineated in deficiencies #1, #3, & #4, the company failed to ensure that the crew carried out all requirements of a proper engineering round, testing of smoke detectors, and inspection of electrical equipment on deck.
*An internal verification of the company procedures pertaining to maintenance of the ship is required within three months.
Action required: 705 - Other - as specified
Due 27 January 2020
Resolved 19 December 2019
Resolution: Vessel provided documentation attesting to the internal verification of the company's maintenance procedures
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 27 October 2019
Resolved
A fixed fire-extinguishing system required by paragraph 5 below may be any of the following systems: a fixed pressure water-spraying fire extinguishing system complying with the provisions of the Fire Safety Systems Code. 74 SOLAS (04) II-2/ 10.4.1.1.3
Any required automatic sprinkler, fire detection and fire alarm system shall be capable of immediate operation at all times and no action by the crew shall be necessary to set it in to operation. F.S.S. Code 8/2.5.1.1
PCCO observed inlet valve providing water to fixed automatic sprinkler system closed. When this valve is closed water will not be supplied automatically in case of emergency use required. The vessel's engine room is UMS.
Action required: 10 - Deficiency Rectified
Due 27 October 2019
Resolved 27 October 2019
Resolution: Chief Engineer stated the valve had been closed prior to test of smoke detectors, and opened valve in presence of PSCO.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 October 2019
Resolved
The means prescribed in paragraph 2.2.3.5.2 which are acceptable to the Administration shall be maintained in the proper condition to ensure their continued accurate functioning in service. 74 SOLAS (14) II-2/4.2.2.3.5.3
PSCO observed aft day service tank sight glass self-closing valve tied in open position, thus presenting large spill and fire hazard.
Action required: 10 - Deficiency Rectified
Due 27 October 2019
Resolved 27 October 2019
Resolution: Chief Engineer cut rope tying valve open in presence of PSCO.
Fire Fighting › Structural - A Class Divisions › Aux Spaces (moderate fire risk)
Issued 30 May 2016
Resolved
74SOLAS(2014 CONS ED)II-1/14.2.1.1.1 The following fire protection systems shall be kept in good order so as to ensure their required perforance if a fire occurs: structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions. Cable trunk room on B Deck has a class "A" penetration leading through to the cable trunk room on C Deck.40ac
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 July 2016
Resolution: RECTIFIED BY CLASS REPORT # LAN 1600143
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 30 May 2016
Resolved
ICLL(88 PROT)REG 8 REG 25.5 Protection for the crew in the form of guard rails or lifelines shall be provided above the deck...Port Side guard rail in the middle just forward of the manifold railing has wasted/worn welding.40ac
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 July 2016
Resolution: RECTIFIED BY CLASS REPORT # LAN 1600143
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 30 May 2016
Resolved
74SOLAS(2014 CONS ED)I/11(a) The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Incinerator would not stay lit.40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 July 2016
Resolution: RECTIFIED BY CLASS REPORT # LAN 1600143
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 30 May 2016
Resolved
74SOLAS(2014 CONS ED)I/11(a) The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. #2 main salt water cooling lines and main engine raw water cooling lines had soft patches.40ac
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 July 2016
Resolution: RECTIFIED BY CLASS REPORT # LAN 1600143