Records from 2003 to 2026. Most recent: inspection, 4 June 2026.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 June 2026
Resolved
The owner shall be prepared to conduct tests and have the vessel ready for inspection of the following: On a sailing vessel all spars, standing rigging, running rigging, blocks, fittings, and sails. Vessel does not have in place a preventative maintenance plan to adequately assess the safe condition of their sail rigging system in accordance with USCG NVIC 02-16. Operator shall schedule a 3rd party rigging survey in the presence of USCG, to include rigging inspection aloft, furler disassembly and provide a survey report.
46 CFR 176.802 (a)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2026
Resolved 24 June 2026
Resolution: Rigging survey completed, report received, and furler disassembled with inspection of fitting, all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 June 2026
No resolution recorded
The owner shall be prepared to conduct tests and have the vessel ready for inspection of the following: On a sailing vessel all spars, standing rigging, running rigging, blocks, fittings, and sails. Vessel does not have a current inventory list in accordance with USCG NVIC 02-16. Provide updated Sail Rig Preventative Maintenance Plan (PMP).
46 CFR 176.802 (a)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2026 — due date passed with no resolution recorded
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 June 2026
Resolved
Each EAP education program must include at least the following elements: display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Policy not on vessel. Provide drug policy.
46 CFR 16.401
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2026
Resolved 5 July 2026
Resolution: Policy provided
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 June 2026
Resolved
The employer shall provide an Employee Assistance Program for all crewmembers that includes both education and training on the effects and consequences of drug and alcohol use. Supervisory personnel must receive at least 60 minutes of training. Missing drug training for supervisors. Provide satisfactory evidence of an Employee Assistance Program including drug awareness training.
46 CFR 16.401
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2026
Resolved 5 July 2026
Resolution: Training completed.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 4 June 2026
Resolved
The float-free link required by 180.130(a)(1) must be of proper strength for the size of the life float as indicated on its identification tag; and secured to the painter at one end and to the vessel on the other end. Float-free link not rated for size of life floats. Properly install the appropriate float-free link(s).
46CFR180.137(b)(2)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2026
Resolved 5 July 2026
Resolution: Weak link provided.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 4 June 2026
Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Vent louver was not closing. Provide operational vent closure.
46 CFR 181.420(a)(3)
Action required: 10 - Deficiency Rectified
Resolved 4 June 2026
Resolution: New relay installed, vent closure operational.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 4 June 2026
Resolved
Provision must be made for closing all supply and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Manual ventilation duct opening port and starboard engine room missing latch allowing the closure to not shut. Provide latches for vent closures.
46 CFR 182.465(h)
Action required: 10 - Deficiency Rectified
Resolved 4 June 2026
Resolution: New latches installd to close vents.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 12 March 2026
Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Vessel has areas of damage to bulwarks starboard aft where cleat ripped out of deck. Provide repair proposal and make repair to damaged area.
46 CFR 177.300 (c)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 April 2026
Resolution: Proposal submitted and repair ompleted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 November 2025
Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temp, and lube oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. Oil pressure gauge port side engine not operational. Make oil pressure gauge operational. Unknown if non-operational electronic gauge affects all engine alarms. Provide operational gauge.
46 CFR 182.410(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 November 2025
Resolution: New gauges provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 November 2025
Resolved
Vessel must be provided with satisfactory arrangement for draining any watertight compartment. Vessel was unable to demonstrate proper operation of the starboard laz electric bilge pump. Bilge piping was not allwoing for float free switch to float free. Prove proper operation of the starboard laz bilge pump.
46 CFR 182.500
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 November 2025
Resolution: Proper operation of starboard laz bilge pump provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 November 2025
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Port side windlass not operational. Provide operational windlass.
46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2025
Resolved 24 February 2026
Resolution: Windlass and wiring removed. Updated electrical plans to follow.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 May 2025
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Stbd aft bilge alarm light is not operational. 15 minute compartment inspections required until deficiency is resolved.
46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2025
Resolved 29 May 2025
Resolution: Repaired and tested high level alarm. All sat.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 2 May 2025
Resolved
A vessel must comply with the structural design requirements of one of the standards listed. Identified two cracked ring frames in the starboard-2 compartment and the starboard lazarette compartment, respectively. Repair at next drydock.
46 CFR 177.300
Action required: 705 - Other - as specified
Resolved 5 November 2025
Resolution: Frame rings repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 2 May 2025
Resolved
A hatch exposed to the weather must be watertight. Gasket material pulling away from hatch on starboard aft hatch. Repair or renew gasket to make compartment watertight.
46 CFR 179.360
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2025
Resolved 29 May 2025
Resolution: Gaskets renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 May 2025
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Life float retroflective tape deteriorated. Renew retroflective tape.
46 CFR 176.808(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2025
Resolved 29 May 2025
Resolution: Renewed retroflective tape.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 July 2024
Resolved
Provide Sail maintenance plan and third party plan for the chain plates.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2024
Resolution: As per TP, chain plates are satisfactory and will be tighten up in upcoming DD. Awaiting SMP...
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 July 2024
Resolved
Life ring buoy was found missing reflective tape. Provide proof of marine reflective tape on life ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2024
Resolved 16 August 2024
Resolution: Vessel applied marine reflective tape and the life ring is now in serviceable condition.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 July 2024
Resolved
MI found 1942 type flex hose installed for worn hydraulic lines. Flex hose must not penetrate watertight bulkheads. Install approved Hydraulic lines or install bulkhead fittings for the flex hoses. Prove proper installation.
Complete in upcoming DD.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 August 2024
Resolved 5 November 2025
Resolution: New hoses provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 July 2024
Resolved
Found wires not connected. Remove dead end wires from vessel and or re-secure wires (bridge, engine rooms, bilge compartments. All wire connections must be made within an enclosure. Prove dead end wires are removed and connections are in enclosures.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 August 2024
Resolved 16 August 2024
Resolution: Dead end wires removed and splices have been corrected and are in satisfactory condition.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 22 July 2024
Resolved
Found life floats missing oars and reflective tapes. Provide marine reflective tape and prove life float are in serviceable condition.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2024
Resolved 23 July 2024
Resolution: Found vessel's life rafts in serviceable condition and with reflective tape and oars.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 July 2024
Resolved
Found PFDs to be without serviceable lights. Provide compliant lights for PFD and prove they are in serviceable condition. Route reduced to limited Coastwise
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 July 2024
Resolved 23 July 2024
Resolution: Approved personal marker lights are attached to each life jacket. Life jackets found in serviceable condition.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 11 October 2023
Resolved
In general, compliance with the standards established by a recognized classification society will be considered satisfactory evidence of structural adequacy of the vessel. Bow compression tube has significant pitting throughout the length of the entire member. Replace bow compression tube and install to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Resolved 31 January 2024
Resolution: Bow compression tube replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 11 October 2023
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Hull structure around the mounting area for the compression tube appears to be cracking. Grind back paint and nonskid to make available for inspection by attending marine inspector.
Action required: 705 - Other - as specified
Resolved 31 January 2024
Resolution: Hull attachment point for bow compression tube made available. Found cracking in fiberglass, hull was repaired.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 11 October 2023
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are employed. Swim step mount in port rudder
room is delaminating. Bolts are allowing minimal water to bleed through. Remove 2 bolts for inspection and grind back delaminated area for inspection by attending marine inspector.
Action required: 705 - Other - as specified
Resolved 31 January 2024
Resolution: Delam area repaired. Bolts removed and replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 October 2023
Resolved
A dry dock examination conducted in compliance with 176.700 must be conducted while the vessel is hauled out of the water. During the examination all accessible parts of the vessel's through hull fittings, including the hull plating and planking, appendages, propellers, shafts, bearings, and rudders shall be made avalaible for inspection. Rudder bearing housings in port and starboard rudder rooms are heavily corroded. Descale both housings to make availabe for inspection by attending marine inspector.
Action required: 705 - Other - as specified
Resolved 31 January 2024
Resolution: Rudder bearing housings were descaled and found in good condition.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 October 2023
Resolved
At each inspection for certification and every other vessel inspections all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Non-structural platform in starboard forward compartment is cracked. Remove platform or repair crack to satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Resolved 31 January 2024
Resolution: Platform repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 11 October 2023
Resolved
Each hatch exposed to the weather must be watertight. Each hatch cover must have securing devices. Two hatches forward of the superstructure are missing locking toggles, making both compartments not watertight. Install locking toggles or replace hatches to make both compartments watertight.
Action required: 705 - Other - as specified
Resolved 31 January 2024
Resolution: Hatch cover secured.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 May 2023
Resolved
Vessel has a Coast wise routes and shall have approved lights on all life jackets. MI found the life jackets with glow sticks attached to them. Prove life jackets have approved personal marking lights.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 8 June 2023
Resolution: Vessel installed approved PMLs for each life jacket onboard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 May 2023
Resolved
Vessel's raycor fuel filters have drain valves installed without a plug or cap to prevent an accidental discharge. Provide caps or plugs and prove they are properly installed and capable of preventing fuel from discharging into the bilge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 8 June 2023
Resolution: Vessel has installed capable plugs to prevent fuel from leaking into the bilge.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 May 2023
Resolved
Vessel grounding wires were missing fasteners at designated location or found laying next to the intended terminal. In addition, terminal wires on batteries were found lose.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 June 2023
Resolved 8 June 2023
Resolution: All ground wires for the vessel are fasten to it's designated terminal.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 31 May 2023
Resolved
Vessel high water float switches are not satisfactory fasten to the deck and float up as the water rises not alarming as per design.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 June 2023
Resolved 31 May 2023
Resolution: All float switches for the high water alarm have been properly secured and operate satisfactory.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 31 May 2023
Resolved
MI found 40 BC fire extinguisher no longer serviceable and previous TP service report deemed it bad. Provide approved replacement and prove installation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 May 2023
Resolved 31 May 2023
Resolution: New serviceable 40BC was installed in replace on the bad extinguisher.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 31 May 2023
Resolved
Vessel's fwd compression tube running between both hulls has two 6 inch cracks were the railing fastens to it. Provide repairs and prove repair is satisfactory with NDT.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 2 June 2023
Resolution: Cracks have been satisfactory repaired and tested. Compression tube will be replaced in upcoming DD.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 May 2022
Resolved
Vessel does not have a sail plan. Currently company utilizes TPO to conduct annual inspections. TPO issued furler discrepancy and the jib sail is not to be used until parts are replaced. Provide sail plan or a copy from TPO and complete satisfactory repairs to the furler with TPO approval.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2022
Resolved 21 June 2022
Resolution: TPO rigger rebuilt the jib sail and all associated components, head stay, furler, pins, etc. All satisfactory.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 May 2020
Resolved
Fixed fire extinguishing systems required to be serviced. The installed fixed fire extinguishing systems for the engine rooms has not been serviced in the last 12 months. Provide evidence of servicing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2020
Resolution: Recieved satisfactory servicing report completed by authorized servicing technician.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 30 April 2018
Resolved
The stowage location of child life jackets must be appropriately marked so they are not mistaken for adult jacket. The stowage location of the child life jackets was not properly marked. Provide adequate marking for the stowage location of the child life jackets.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 May 2018
Resolved 17 May 2018
Resolution: Deficiency was corrected prior to completing the inspection.
Sail Rigging › Spars › Boom and Gooseneck Fitting
Issued 20 November 2017
Resolved
The mainsail and boom were not installed by the rigger after the mast was stepped because a new sail is being constructed. Upon installation and before use, the rig must be inspected by a Coast Guard Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 17 May 2018
Resolution: The mainsail has been temporarily removed the vessel due to continuing issues with the internal furling system. A modification is in development with a local rigger to relocate the furling system from internal to the mast to external.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 November 2017
Resolved
Vessels are required to have navigation lights per COLREGS. Vessels anchor light is missing. Vessel is restricted to daytime operations until anchor light is provided.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 5 December 2017
Resolution: Verified the vessels anchor light was installed and operational.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 20 November 2017
Resolved
Vessels with pre-engineered fixed gas fire extinguishing systems are required to automatically shut down engines within the protected space. The system in the port engine room failed to secure the port engine. Prove proper operation of the port engine room fixed fire extinguishing system.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2017
Resolution: CG Marine inspector witnessed proper operation of the fixed fire extinguishing system.
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 November 2017
Resolved
Vessels at least 26 feet in length must have an audible and visual bilge high water level alarm indicator at the operation station. Vessel's bilge high water level alarm is wired on the same circuit as the bilge pump auto switch. If this switch were secured then the alarms would not sound. Vessel is required to conduct inspection of bilges every 15 minutes while passengers are on board. Vessel is also required to carry one additional deckhand until bilge alarm is wired on a dedicated circuit.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 December 2017
Resolved 5 December 2017
Resolution: Verified the bilge high water alarm system and bilge pumps were operational.
Sail Rigging › Chainplates › Materials
Issued 1 November 2017
Resolved
The port and stbd padeyes for the forward bridle are severely corroded and elongated. They hold ¾” pins and in the direction of the load path have been elongated to over 1” on the STBD side and about 15/16” on port side.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 November 2017
Resolution: A modification to the chain plates was made. See activity# 6299132 narrative for details.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 1 November 2017
Resolved
Stbd hull berth area – identified a previous FRP and resin repair that is failing to bond to vessel structure. Old repair is to be removed and a new repair is to be made.
Removal of old repair revealled a 4" x 4" section of rotten wood core. The wasted core is to be cropped and renewed.
Action required: 705 - Other - as specified
Resolved 20 November 2017
Resolution: Repairs were made, inspected and found to be satisfactory.