Records from 2004 to 2017. Most recent: inspection, 21 July 2017.
Inspection history · 32
21 July 2017
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6255684
3 February 2017
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6087474
30 August 2016
MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5983250
22 April 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5860108
1 March 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5825783
1 March 2016
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5827165
23 December 2015
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5786494
2 October 2014
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4997911
2 October 2014
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4997918
17 July 2014
Drydock Exam · Examination of Repairs · COI Inspection · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4924467
18 May 2014
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4864429
30 December 2013
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4752875
31 October 2012
Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4475396
26 September 2012
Examination of Repairs · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4452329
31 March 2012
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4294126
31 January 2012
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4235615
24 January 2012
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4231377
16 December 2011
Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4216129
22 November 2011
Periodic Inspection · MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4202247
15 November 2011
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4203609
7 December 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3906907
22 November 2010
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3887967
28 October 2010
Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3883725
28 October 2010
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3903984
12 May 2010
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3736664
1 October 2007
Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3068355
10 October 2006
Annual Inspection · MTSA Verification · MARPOL Annex I Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2798717
9 December 2005
MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2548997
12 March 2005
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2308953
7 January 2005
MTSA Verification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2270467
24 August 2004
Construction Oversight · Initial Certification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2175097
11 August 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2162853
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 22 April 2016
Resolved
Prove proper operation of liquid overfill protection arrangements: high level alarm in starboard #3 tank.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2016
Resolved 22 April 2016
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 23 December 2015
Resolved
Prove proper valve position indicator on two valves located on #2 starboard cargo tank. 46 CFR 56.20-9
Condition: Improper Installation
Due 30 January 2016
Resolved 27 January 2016
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 23 December 2015
Resolved
Prove proper operation of portside cargo pump emergency shutdown.
33 CFR 156.170(c)(5) Vessel may not use portside pump until proof of satisfactory E-Stop has been demonstrated to an attending MI.
Action required: 705 - Other - as specified
Due 30 December 2015
Resolved 27 January 2016
Resolution: Shutdowns function properly
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 December 2015
No resolution recorded
Renew wasted portions of MC cable jacketing running aft to bow. 46 CFR 111.60-23
Due 17 July 2017 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 December 2015
Resolved
Renew wasted wire run supports 32 are wasted labeled from aft to bow.
46 CFR 111.60-5
Due 1 March 2016
Resolved 27 January 2016
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 December 2015
Resolved
Renew wasted crane pedestal machinery guard. 46 CFR 32.02-15
Due 30 January 2016
Resolved 27 January 2016
Deck/Cargo › Holds/Tanks › Hatch
Issued 23 December 2015
Resolved
Number to port cargo tank sight glass gasket not vapor tight. 46 CFR 39.20-3(a)(1)
Due 30 January 2016
Resolved 27 January 2016
Deck/Cargo › Cargo Stowage › General
Issued 2 October 2014
Resolved
Provide Marine Chemist Certificate to verify vessel is gas freed prior to movement. Vessel shall not carry cargo until inspected and approved by attending Maine Inspector.
Action required: 705 - Other - as specified
Resolved 2 October 2014
Resolution: See narrative.
Electrical › Electrical Distribution System (service) › Cable
Issued 31 October 2012
Resolved
Replace welding cables with marine grade battery cables.
Condition: Improper Installation
Due 30 November 2012
Resolved 21 November 2012
Engineering › Fuel Oil Service System › Valve, Control
Issued 31 October 2012
Resolved
Provide remote F/O stops for machinery.
Condition: Improper Installation
Due 30 November 2012
Resolved 21 November 2012
Fire Fighting › Ventilation Systems › Ducts
Issued 31 October 2012
Resolved
Prove proper operation of machinery space ventalation dampners.
Condition: Improper/Lack of Maintenance
Due 30 November 2012
Resolved 21 November 2012
Operations/Management › Casualty Reporting/Post-Casualty Actions › Notice of Marine Casualty
Issued 26 September 2012
Resolved
Cease all towing operation until causative factors of the broken tow gear have been determined and affective repairs have been made as necessary.
Action required: 705 - Other - as specified
Resolved 27 September 2012
Resolution: It was determined that the cause of the casualty was a catastrophic failure of the shackle binding the chain to the fish plate. All shackles were replaced with ABS approved shackles.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Notice of Marine Casualty
Issued 26 September 2012
Resolved
Prove to the attending Marine Inspector that all towing gear effected has been returned to original condition.
Action required: 705 - Other - as specified
Resolved 27 September 2012
Resolution: Verified repairs via photograph evidence; did not physically attend.
Construction/Loadline › Hull › Weld
Issued 1 October 2007
Resolved
Cracked weld in #1 port void, 12th bottom long between #8 and #9 frame.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 October 2007
Resolved 10 October 2007
Resolution: Received digital photos of satisfactory repair.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 1 October 2007
Resolved
Not properly labeled with date of latest test.
Action required: 705 - Other - as specified
Due 31 October 2007
Resolved 11 October 2007
Resolution: Received digital photos of properly labeled hoses.