EL LOBO GRANDE II

Built
1978
Last inspected
9 March 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 9 March 2026
…with no type recorded16
Operational controls None recorded without a removal date
Years with a record 20 calendar years (1994–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7802641
WDP6369
162402
Flag
UNITED STATES
Maury page id
psix-162402

Documentation record

Registered dimensions (L × B × D)127.2 ft × 36.5 ft × 10.8 ft
Registered tonnagegross 199 / net 135
ITC dimensions (L × B × D)128.7 ft × 36.5 ft × 19.0 ft
ITC tonnagegross 563 / net 168
BuilderMCDERMOTT SHIPYARDS · AMELIA, LA, UNITED STATES · built 1978
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portST CROIX, VI
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 4 June 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it135 - Regulatory (Subpart C or D), Net Ton
168 - Convention (Subpart B), Net Ton
199 - Regulatory (Subpart C or D), Gross Ton
563 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 45 inspections, each with its date, unit and type; 35 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 6 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 6

Inspection history · 45

9 March 2026 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8322814
8 March 2026 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8361850
14 February 2026 In-Service Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8313474
21 December 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8287363
27 April 2025 Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8127421
31 March 2025 Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8102360
19 March 2025 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8096556
15 December 2024 Damage Survey
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 8048582
5 November 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8031159
4 November 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8032147
25 September 2024 MTSA/ISPS Verification · Administrative Inspection · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8009397
28 December 2023 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7843257
15 September 2022 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7552909
25 August 2022 Drydock Exam · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7543704
16 May 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7452264
3 August 2021 Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7281942
4 June 2021 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7218532
17 September 2020 Initial Certification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7060132
20 July 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7013619
13 July 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7005211
30 July 2019 Bulk Liquid Transfer Monitor
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6767369
23 February 2016 Administration
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5822015
27 November 2015 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5771003
8 May 2015 Marine Casualty Follow Up
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5123758
6 May 2015 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5136495
23 February 2015 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5151603
12 January 2015 Administration
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5052022
19 May 2014 Marine Casualty Follow Up
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4862336
18 May 2014 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4864429
12 November 2013 MTSA Verification · DAPI Audit · Industry Initiated Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4751483
1 May 2013 Marine Casualty Follow Up
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4582574
28 July 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4395550
31 March 2012 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4294126
7 December 2010 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3906907
28 October 2010 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3903984
27 October 2010 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3903887
17 September 2010 Industry Initiated Exam · MTSA Verification · Deficiency Check · Administration
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3851874
2 March 2009 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3444472
12 June 2007 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2970322
16 August 2004 MTSA/ISPS Verification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2164391
28 July 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2148209
3 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1958299
9 January 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 644338
13 December 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 84479
21 September 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 51753

Deficiency record · 35

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 March 2026 Resolved
Propulsion machinery, including main engines, reduction gears, shafting, bearings, and electrical equipment and systems, must be maintained to ensure proper operation; Stbd engine failure resulted in a loss of propulsion. Demonstrate proper operation to an attending marine inspector prior to returning to operations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2026
Resolution: Vessel replaced faulty fuel injector. Satisfactory Sea Trial completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 February 2026 Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. MI Observed fuel leak on F/O separator in aft port engineroom on Deck. Repair or Remove from Service. - 46 CFR 143.220 - 17(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2026
Resolution: Witnessed new hose assembly installed to allow water to drain directly in bilge.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 14 February 2026 Resolved
Nothing in this subpart limits the marine inspector from conducting any tests or inspections he or she deems necessary to be assured of the vessel's seaworthiness or fitness for its route and service. MI Observed steering Room had three foot of water within the bilge, report received showed water ingress originating from on or around the rudder stock. Provide Repair plan. - 46 CFR 137.200(d) - 701(a,c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 February 2026
Resolution: ABS report attached in documents.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 14 February 2026 Resolved
The master must ensure that all hatches and other openings designed to be watertight or weather-tight function properly. Aft STBD Void Vent pipe was severely corroded. A six inch by eight inch hole was found in the pipe. Provide repair plan and crop and renew. 46 CFR 140.610(b) 701(a,c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 February 2026
Resolution: ABS report in documents.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 14 February 2026 Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided... High Bilge level. MI tested Aft Bilge alarm, inop. 46 CFR 143.230(a)(5) - 701
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2026
Resolution: Tested Aft Bilge Alarm, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 February 2026 Resolved
There must be an installed or portable bilge pump for emergency dewatering. Any portable pump must have sufficient hose length and pumping capability. All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended back flooding through bilge piping. MI was unable to test aft bilge suction where water accumulation was observed due to hydraulic oil contamination from steering gear. MI to test Bilge suction once aft steering room is cleaned.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 February 2026
Resolution: witnessed satisfactory test of emergency dewatering system from engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 February 2026 Resolved
All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Steering room bilge was observed to have a high level of water with hydraulic oil. Remove excess oily water, clean steering room bilges in preparation for MI to test bilge suction. of the space. 46 CFR 142.220(a) - 701 c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2026
Resolution: Verified steering compartment clear of oily water.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 14 February 2026 Resolved
A vessel must be operated iaw applicable lawas and regulaions. Test of crew familiarty with flooding drill. Crew could not demonstrate floding responce to partiular compartement from the fixed bilge manifold or align valves to operate system. 46 CFR 137.200 - 17 (c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2026
Resolution: witnessed satisfactory test of emergency dewatering system from engine room.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 14 February 2026 Resolved
Piping must be fitted with isolation valaves that are clearly marked by labling or color coding that enable the crew to identify its function. Manifold for bilge suction was not labled correctly or colored for crew to quickly respond in case of emergency. Include instructions for operation of the bilge dewatering system for alignment of valves and pump operations. 46 CFR 143.250 - 17 c
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 February 2026
Resolution: witnessed satisfactory test of emergency dewatering system from engine room. extended deficiency to allow vessel to come into compliance with properly labling system.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 15 April 2025 Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires, The control panel includes: A power available light. Repair power available on panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2025
Resolved 27 April 2025
Resolution: Attending MI received photo evidence clearing deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 April 2025 Resolved
All lifesaving equipment must be tested and maintained in accordance with the minimum requirements of § 199.190 of this chapter, as applicable. Produce lifesaving maintenance log for vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2025
Resolved 27 April 2025
Resolution: Attending MI received photo evidence clearing deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 15 April 2025 Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with an indicating pressure gauge (in a readily visible location. Provide gauge with sufficient range to read past pressure vessel MAWP of 250 PSI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2025
Resolved 27 April 2025
Resolution: Attending MI received photo evidence clearing deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 15 April 2025 Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Install sight glass protectors for all sight glasses in the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2025
Resolved 27 April 2025
Resolution: Attending MI received photo evidence clearing deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 April 2025 Resolved
Essential systems or equipment must be regularly tested and examined. Provide log in accordance with this regulation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2025
Resolved 27 April 2025
Resolution: Attending MI received photo evidence clearing deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 April 2025 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Seal all openings on the side of the main electrical switchboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2025
Resolved 27 April 2025
Resolution: Attending MI received photo evidence clearing deficiency.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 15 April 2025 Resolved
Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire. Identify and label engine room emergency ventilation stops.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2025
Resolved 27 April 2025
Resolution: Attending MI received photo evidence clearing deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 April 2025 Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. Provide and mount dogging wrench needed to properly close Port aft main watertight door of the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2025
Resolved 27 April 2025
Resolution: Attending MI received photo evidence clearing deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 April 2025 Resolved
A towing vessel 79 feet or more in length must carry four lifebuoys, with one lifebuoy located on each side of the operating station. Lifebuoys must be at least 610 millimeters (24 inches) in diameter. Replace the aft 2 lifebuoys due to decayed lines IAW with this subchapter.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2025
Resolved 27 April 2025
Resolution: Attending MI received photo evidence clearing deficiency.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 17 December 2024 Resolved
The cognizant OCMI may require additional examinations of the vessel whenever he or she discovers deterioration that may affect the seaworthiness or fitness for the route or service of the vessel. #3 STBD fuel tank developed a leak in the lazarette bulkhead due to wasted steel. Vessel must keep #3 STBD fuel tank empty, place damaged fuel tank out of service, have USCG inspect fuel tank, and vessel must repair all wasted steel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2025
Resolved 31 March 2025
Resolution: ABS report received.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 15 September 2022 Resolved
All machinery and equipment that is not in proper working order (including missing or malfunctioning guards or safety devices) must be removed; made safe through marking, tagging, or covering; or otherwise made unusable. Aft end of both reduction gear units have exposed rotating machinery.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2022
Resolved 5 October 2022
Resolution: Added guard.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 September 2022 Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR part 84 as appropriate to its area of operation. Top red restricted in ability to maneuver light and forward upper towing light were inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2022
Resolved 5 October 2022
Resolution: Verified proper operation of lights.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 15 September 2022 Resolved
Towing vessels must be equipped with the following equipment, as applicable to the area of operation: (d) Illuminated magnetic compass or an illuminated swing-meter (Western Rivers vessels only). The compass or swing-meter must be readable from each operating station. Compass light was inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2022
Resolved 5 October 2022
Resolution: Verified proper operation of the light.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 15 September 2022 Resolved
All machinery and equipment that is not in proper working order (including missing or malfunctioning guards or safety devices) must be removed; made safe through marking, tagging, or covering; or otherwise made unusable. Dryer vent was stuck in closed position.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2022
Resolved 5 October 2022
Resolution: Veried vent operated freely.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 September 2022 Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following: (a) All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. Shaft alley bilges contained excessive oily rags and liquid.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2022
Resolved 5 October 2022
Resolution: Oil and rags were removed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 September 2022 Resolved
(b) Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space and must be either: (1) Automatic, battery-operated with a duration of no less than 2 hours; or (2) Non-electric, phosphorescent adhesive lighting strips that are installed along escape routes and sufficiently visible to enable egress with no power. Emergency lighting was inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2022
Resolved 5 October 2022
Resolution: Blacked out the vessel and verified e-light were adequate for egress from work and accommodation spaces.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2022 Resolved
Make the cofferdam ready for inspection by removing the water and descaling the lower forward transverse bulkhead to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Resolved 26 August 2022
Resolution: 26AUG22: Inspected SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 25 August 2022 Resolved
Prove the proper operation of the watertight door between the lower accommodation space and the engine room to the satisfaction of the attending Marine Inspector. All dogs did not land on striker plates.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2022
Resolved 5 October 2022
Resolution: Completed chalk and operational test SAT.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2022 Resolved
Steering gear room, crop and renew the wasted aft STBD overhead frame and the FWD STBD bulkhead vertical stiffener to the satisfaction of the attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2022
Resolved 28 December 2023
Resolution: Replaced woth good steel; NDT successful.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2022 Resolved
Aft peak, crop and renew the wasted frames and vent as marked/discussed and areas identified by by thickness gauging with greater than 25% wastage to the satisfaction of the attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2022
Resolved 28 December 2023
Resolution: Replaced with good steel. NDT successful.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 August 2022 Resolved
Main deck, repair the watertight doors to properly center the doors on the gaskets (aft port door)and make tight by adjusting the bottom inboard dog (FWD STBD).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2022
Resolved 28 December 2023
Resolution: Gaskets replaced on watertight doors. Seal effective and spray test successful.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 25 August 2022 Resolved
Main deck, crop and renew the holed air vent pipe for the Wash TK Vent FWD STBD to the satisfaction of the attending Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2022
Resolved 5 October 2022
Resolution: Installed a knid kind vent pipe.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 August 2022 Resolved
P&S ballast tanks coating has failed, make ready for inspection by removing scale and qualify base plate thickness via UT at the vessel's 2025 drydock.
Action required: 705 - Other - as specified
Due 31 August 2025
Resolved 2 December 2024
Resolution: Tank coating replaced at 2024 dry dock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 August 2022 Resolved
Qualify the port and starboard propellers. The port propeller appeared to have an approx. 2" linear discontinuity on its hub and the starboard a 3" along zone A of a single blade.
Action required: 705 - Other - as specified
Resolved 2 September 2022
Resolution: Sound propeller performed repairs and provided a TPO report.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 25 August 2022 Resolved
Qualify or provide a corrective action plan for the previous conversion of the fore peak ballast tank to a potable water storage tank. Potable water storage tanks should be independent with no common boundaries with the ships shell unless the bottom of the tank terminates at least 2 feet above the maximum load waterline and the manhole shall not be located on the tank top when it is formed by the deck. Repair the failed coating with an approved potable water tank coating system and provide documentation. PHS Publication 393,"Handbook on Sanitation of Vessel Construction, Section A.6.
Action required: 705 - Other - as specified
Resolved 2 September 2022
Resolution: The vessel provided original GA identifying the tank as a fresh water tank. Tank is grandfathered.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 July 2020 Resolved
All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the 25% of the vessels that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days. If an inspection is not completed prior to this date, the action for this deficiency shall be changed to a 60 (Rectify deficiencies prior to movement) and the vessel may no long be permitted to operate.
Action required: 705 - Other - as specified
Due 13 October 2020
Resolved 9 December 2020
Resolution: Vessel obtained COI

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.