MAURY USCG vessel records Sign in
← All vessels

WAHINE KAI

WAHINE KAI is a 2004 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 2005, most recently in July 2025, along with 49 deficiencies and 4 casualty investigations between 2008 and 2013.

Records from 2005 to 2025. Most recent: inspection, 16 July 2025.

Built
2004
Last inspected
16 July 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI9700
671592
Flag
UNITED STATES
367751270
Maury page id
psix-671592

Inspections, by type

…with no type recorded2
Years with a record 16 calendar years (2005–2025)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)37.5 ft × 9.0 ft × 3.9 ft
Registered tonnagegross 8 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPACIFIC SHIPYARDS INTERNATIONAL LLC · HONOLULU, HI, UNITED STATES · built 2004
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portLAHAINA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Gross Ton
8 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI9700MMSI 367751270 · active · compulsorily equipped · granted 29 May 2026, expires 17 August 2036
WDC7382MMSI 367070610 · expired · compulsorily equipped · granted 22 July 2015, cancelled 7 March 2026 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 24

16 July 2025 COI Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8186904
6 August 2024 Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 7975951
17 November 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7826126
10 August 2022 Deadweight Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7541068
2 August 2022 Annual Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7522724
8 February 2022 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7392334
3 November 2021 DAPI Audit · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7346662
15 September 2021 Special Consideration · Appeal
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7338042
18 August 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7288923
18 August 2020 COI Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7035937
19 January 2020 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6897349
14 August 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6783371
16 August 2018 Administrative Inspection · Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6515324
5 September 2017 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6260517
16 August 2016 Hull Examination · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6024417
5 July 2016 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5930912
27 August 2015 Administrative Inspection · Hull Examination · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5215352
27 October 2014 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5013263
11 March 2014 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4828898
4 September 2008 Deficiency Check · Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3322232
7 February 2008 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3220869
9 November 2007 Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3094111
19 July 2006 Simplified Stability Test
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2728167
5 April 2005 Plan Review "T" Boat · Initial Certification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2327224

Deficiency record · 49

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 August 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Port forward stanchion deck plate found with approximately 2" crack, requires replacement. 46 CFR 177.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2024
Resolved 14 August 2024
Resolution: Approved weld repair for 2" crack on stanchion deck plate
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 6 August 2024 Resolved
A duct must be of rigid permanent construction, made of the same material as the hull or of noncombustible material. Provision must be made for closing all exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Fuel tank compartment vents modified with PVC pipe require removal and vent openings require closing mechanism. Blocking vent opening with a rag is not accepted. 46 CFR 182.460(h)(l)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2024
Resolved 17 September 2024
Resolution: New metallic scoops and closure devices installed.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Ship's occupational safety and health policies and programmes
Issued 6 August 2024 Resolved
Each EAP education program must include display and distribution of informational material; a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Hot-line numbers not posted on vessel. 46 CFR 16.401
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2024
Resolved 14 August 2024
Resolution: Hotline posted on board
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 November 2023 Resolved
On a vessel of at least 26 feet a visual alarm must be provided at the operating station to indicate a high water level. The visual alarm was not operational. Demonstrate visual and audible alarm for high water level to attending marine inspector. 46 CFR 182.530(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2023
Resolved 8 December 2023
Resolution: Visual and audible alarm operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 November 2023 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length, but not more than 6 feet, securing the waterlight around the body of the ring life buoy. Vessel's ring life buoy's floating waterlight lanyard was less than 3 feet in length and incorrectly secured to the ring life buoy. Install appropriately sized lanyard for ring life buoy and properly secure to ring life buoy body. 46 CFR 180.70(d)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2023
Resolved 8 December 2023
Resolution: proper length lanyard provided.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 November 2023 Resolved
Procedures for checking the proper operation of a flammable vapor detection system must be posted at the primary operating station. Procedures for vapor detection system operation were not posted. Post appropriate procedures for checking the proper operation of a flammable vapor detection system at the operating station to the satisfaction of the attending marine inspector. 46 CFR 182.480(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2023
Resolved 8 December 2023
Resolution: Flammable vapor detection procedures provided.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 2 August 2022 Resolved
Provision must be made for closing all exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. Gasoline tank space blower exhaust does not have a means of closing. Provide closure for blower exhaust from gasoline tank space. 46 CFR 182.460(l)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2022
Resolution: Vent closure provided.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 2 August 2022 Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link (weak Link) permanently attached to the vessel. Weak link shall be correct for the size of the life float. Current weak link is designed for smaller life float. Provide proper weak link. 46 CFR 180.130
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2022
Resolved 6 September 2022
Resolution: Weak link provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 August 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2022
Resolved 9 September 2022
Resolution: Work Instruction 31 procedures provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 August 2022 Resolved
A red warning sign at the exhaust blower switch must state that the blowers must be operated prior to starting the engines for the time sufficient to insure at least ones complete change of air in the space served. Sing currently in place but it is not red. Provide red sign. 46 CFR 182.460(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2022
Resolved 1 September 2022
Resolution: Red sign posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 August 2022 Resolved
Each inlet that penetrated the hull below a line drawn parallel to and at least 6 inches above the deepest load waterline must have a means to prevent water from entering the vessel if the pipe fractures or otherwise fails. Port and starboard deck drain valves are inoperable. Provide operational port and starboard deck drain valves. 46 CFR 179.350(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2022
Resolved 1 September 2022
Resolution: New valves provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 August 2022 Resolved
A propulsion engine control system must be designed so that a loss of power to the control system does not result in an increase in shaft speed. Vessel is equipped with a fly-by-wire throttle system, however QFA and DVTP was never provided and test was not completed. Provide to the Marine Safety Center for review and approval QFA and DVTP in accordance with CVC-Policy Letter 17-07 and conduct testing QFA and DVTP once QFA and DVTP have been approved by MSC. 46 CFR 184.620(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2022
Resolved 19 October 2022
Resolution: DVTP submitted and approved. Testing completed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 August 2022 Resolved
The owner/operator shall submit drawings describing any alterations. Proposed alterations must be approved. New engines with different electrical wiring installed. Provide updated vessel one-line electrical plans to the Marine Safety Center(MSC) for review and approval. 46 CFR 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2022
Resolved 22 June 2023
Resolution: MSC approved and locally approved electrical installation complete.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 August 2022 Resolved
Machinery and equipment shall be installed and maintained in such a manner to afford adequate protection from causing a marine casualty. Fuel shut off valve handles were not a perfect fit with valve. Valve handle could spin 360 degrees making it unknown if valve were open or closed. Provide new fuel shut off valves. 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2022
Resolved 1 September 2022
Resolution: New valve handle provided.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 2 August 2022 Resolved
Where the amount of carbon dioxide gas required in a fixed fire extinguishing system can be supplied by one portable extinguisher such an extinguisher may be used. Currently fuel tank space has a ABC fire extinguisher being used. Provide a CO2 extinguisher and verify that contents will cover CUFT of space. 46 CFR 181.400(b)(5)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 September 2022
Resolved 9 August 2022
Resolution: Proper CO2 bottle provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 November 2021 Resolved
All agreements and arrangements, written or unwritten, between and among employers and service agents concerning the implementation of DOT drug testing requirements are deemed, as a matter of law, to require compliance with all applicable provisions of this part and DOT agency drug testing regulations. Marine Inspector identified insufficient Company Drug & Alcohol Policy. Update Company Drug & Alcohol Policy to reflect sample provided in Marine Employer's Drug Testing Guide. Identify SAP and provide contact information to all employees.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2021
Resolved 2 February 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 November 2021 Resolved
The marine employer shall ensure that all persons directly involved in a serious marine incident are chemically tested for evidence of dangerous drugs and alcohol in accordance with the requirements of 46 CFR 4.06. Develop a plan for after hours collection for Post-Accident DOT chemical tests.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2021
Resolved 2 February 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 November 2021 Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and Supervisory personnel must receive at least 60 minutes of training. Provide proof of completed EAP training for all personnel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2021
Resolved 2 February 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 November 2021 Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Provide proof of pre-employment tests or acceptable alternative as required by this cite for individuals in a safety sensitive position.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 December 2021
Resolved 2 February 2022
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 18 August 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2021
Resolved 14 September 2021
Resolution: MMC medical card provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 August 2021 Resolved
Vessel COI has condition that it meets Work Instruction 31 (crew can enter water while moored or anchored). AED required to meet this policy. AED pads where expired. Provide new AED pads to meet Work Instruction 31. Work Instruction 31
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2021
Resolved 14 September 2021
Resolution: AED pads provided.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 18 August 2021 Resolved
Life float water light line required to be 18 feet in length. Actual line on board was approximately 3 feet. lengthen life float water light line to 18 feet. 46 CFR 180.175
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2021
Resolved 14 September 2021
Resolution: Life float water light line provided.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 18 August 2021 Resolved
Flexible fuel hose must not have any cracks or show wear. Flexible fuel hose after filter to outboard engines showing cracking. Provide CG approved new fuel hose. 46 CFR 182.720
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2021
Resolved 14 September 2021
Resolution: New hose provided.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 18 August 2021 Resolved
Primary lifesaving equipment shall be maintained with no visible damage. Buoyant Apparatus(BA) showing cracking and holes. Replace BA with CG approved Life Float. Each vessel certified to operate on a limited coastwise route in warm water must be provided with Life Floats of an aggregate capacity that will accommodate at least 50% of the total number of persons permitted on board. Provide approved Life Floats to meet 50% of the total number of persons permitted. Replace when shipment arrives, date of closure based on shipping. 46 CFR 180.205(c)
Action required: 705 - Other - as specified
Resolved 22 December 2021
Resolution: New life float provided and installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 August 2021 Resolved
Vessel required to have interlock for blower switch. Vessel exhaust blower interlock not operational on vessel that has fuel tanks for gasoline. Blower switch must be of the type interlocked with the starting switch and the ignition switch so that the blowers are started before the engine starter motor circuit or the engine ignition is energized. Provide operational interlock. 46 CFR 182.460(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2021
Resolved 7 February 2022
Resolution: Ignition interlock installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 August 2020 Resolved
Safety Radio Certificate required by FCC is expired. Provide valid radio safety certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2020
Resolved 13 October 2020
Resolution: Safety Radio Certificate provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 August 2020 Resolved
01 Portable Fire extinguisher has broken gauge glass. Replace with new gauge glass.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2020
Resolved 13 October 2020
Resolution: New portables provided.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 19 August 2020 Resolved
VHF does not have DSC capabilities. Make VHF radio have DSC capabilities.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2020
Resolved 28 August 2020
Resolution: VHF now DSC capable.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 August 2020 Resolved
Vessel name and hailing port missing on stern. Provide vessel name and hailing port on stern.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2020
Resolved 31 August 2020
Resolution: Name and hailing port on stern.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 August 2020 Resolved
Port engine gear control cable not functioning. Caused engine to shutdown. Replace cable and conduct sea trials for credit drydock and COI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2020
Resolved 28 August 2020
Resolution: New cable installed. Sea Trials conducted. All sat.
Communications › Radio Communications › EPIRB
Issued 5 September 2017 Resolved
Battery expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 September 2017
Resolution: E-pirb battery renewed.
Engineering › Bilge Water Management System › Not Operational
Issued 5 September 2017 Resolved
Indicator light for automatic bilge pump not illuminating.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 8 September 2017
Resolution: Light repaired.
Engineering › Bilge Water Management System › Manifold
Issued 27 August 2015 Resolved
Replace FWD compartment bilge suction handle with correct one.
Due 3 September 2015
Resolved 5 July 2016
Resolution: Bilge handle was replaced.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 27 October 2014 Resolved
Provide updated Safety Radio Certificate.
Due 27 November 2014
Resolved 27 November 2014
Resolution: Vessel was issued a new Safety Radio Certificate
Operations/Management › Drills/Instruction › Not Conducted
Issued 27 October 2014 Resolved
Log drills IAW regulations and company policies.
Due 27 October 2014
Resolved 27 October 2014
Resolution: Educated Captain and crew on importance of logging drills and safety equipment checks.
Engineering › Bilge Water Management System › Interface Detector
Issued 4 September 2008 Resolved
Bilge Alarm does not have visual indicator.
Condition: Improper Installation
Due 11 September 2008
Resolved 11 September 2008
Resolution: Corrected.
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 4 September 2008 Resolved
EPIRB registration is expired.
Condition: Placed in Improper Service
Due 11 September 2008
Resolved 11 September 2008
Resolution: Provided proof of purchase.
Lifesaving › Lifefloat › Float Free
Issued 4 September 2008 Resolved
EPIRB hydrostatic release is expired.
Condition: Improper/Lack of Maintenance
Due 11 September 2008
Resolved 11 September 2008
Resolution: Provided proof of purchase.
Lifesaving › Lifefloat › Float Free
Issued 4 September 2008 Resolved
Life float hydrostatic release expired.
Condition: Improper/Lack of Maintenance
Due 11 September 2008
Resolved 11 September 2008
Resolution: Provided proof of purchase.
Lifesaving › Lifefloat › Float-free Link
Issued 4 September 2008 Resolved
Life float weak link installed incorrectly.
Condition: Improper Installation
Due 11 September 2008
Resolved 11 September 2008
Resolution: Corrected.
Lifesaving › Visual Distress Signals (General) › Storage
Issued 4 September 2008 Resolved
Life float light not connected properly.
Condition: Improper Installation
Due 11 September 2008
Resolved 11 September 2008
Resolution: Corrected.
Engineering › Bilge Water Management System › Not Operational
Issued 4 September 2008 Resolved
Automatic bilge pump needs visual indicator at operator's station when operating.
Condition: Improper/Lack of Maintenance
Due 11 September 2008
Resolved 11 September 2008
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 4 September 2008 Resolved
Replace port side foot strap.
Condition: Improper Installation
Due 11 September 2008
Resolved 11 September 2008
Resolution: Corrected.
Engineering › Bilge Water Management System › Interface Detector
Issued 9 November 2007 Resolved
Provide high water alarm for head space.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 November 2007
Resolved 7 December 2007
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 9 November 2007 Resolved
Restencil (6) CG adult lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 November 2007
Resolved 13 November 2007
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 9 November 2007 Resolved
Provide no smoking sign.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 November 2007
Resolved 9 November 2007
Engineering › Fuel Oil Service System › Valve
Issued 9 November 2007 Resolved
Properly label emergency fuel shutoff valves.
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 November 2007
Resolved 9 November 2007
Operations/Management › Equipment Service/Testing › EPIRB
Issued 9 November 2007 Resolved
Provide valid NOAA registration sticker for EPRIB.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 November 2007
Resolved 7 December 2007
Documentation › Certificates/Documents › FCC SSL
Issued 5 April 2005 Resolved
Provide valid FCC radio certs; FCC Stations License, Operators Permit, Radio Communications Certificate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2005
Resolved 19 October 2005
Resolution: cORRECTED

Casualty record · 4

7 February 2008Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 6 injured · activity 3220869
28 January 2013Routine · role: Involved in a Marine Casualty · activity 4527986
15 June 2013Routine · role: Involved in a Marine Casualty · activity 4623326
23 July 2013Routine · role: Involved in a Marine Casualty · activity 4662420
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

OCEAN ADVENTURER (2008–2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.