Records from 2010 to 2026. Most recent: inspection, 1 May 2026.
Inspection history · 36
1 May 2026
Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8359019
14 July 2025
Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8193229
26 March 2025
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8100261
14 August 2024
Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7981434
27 June 2024
Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7944772
26 June 2024
Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7996275
24 June 2024
In-Service Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7943864
1 June 2023
Internal Structural Exam · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7711495
7 November 2022
Liferaft Servicing
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7592367
5 March 2022
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7404843
16 June 2020
Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6978715
18 March 2020
Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6928660
11 December 2019
Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6871995
24 September 2019
Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6821992
18 September 2019
Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6816993
15 September 2019
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6886579
30 April 2019
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6674355
15 March 2019
Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6643741
7 February 2019
Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6621929
4 December 2018
Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6591571
6 November 2018
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6576052
1 November 2018
Administrative Inspection · DAPI Audit · Internal Structural Exam · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6571394
11 September 2018
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6538094
13 August 2018
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6513347
11 May 2018
Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6413707
13 March 2018
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6370613
9 November 2017
Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6304545
15 September 2017
Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6267608
1 May 2017
Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6136843
13 December 2016
Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6057402
16 November 2016
Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6041956
20 October 2016
Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6026798
4 October 2016
Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6015273
3 May 2016
Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 5870872
28 March 2016
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 5843167
7 January 2016
Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 5795369
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 June 2024
Resolved
Repairs or alterations to machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Repairs or alterations that affect the safety of the vessel include steering.
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed.
Following marine casualty, attended vessel and determined Hydraulic steering linkage for starboard bucket had come apart. Examined intact port linkage and noticed there was no fastener installed to secure linkage together. Provide drawings that detail the bucket linkage to determine manufacturer's design.
Test steering system to the satisfaction of attending Marine Inspector prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2024
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 11 December 2019
Resolved
Conduct Man Overboard and Fire Drills to the satisfaction of an attending USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 December 2019
Resolved 16 June 2020
Resolution: Witnessed satisfactory drills and sea trials.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 September 2019
Resolved
Prove proper operation of the throttles the CG inspector attending.
Action required: 10 - Deficiency Rectified
Resolved 19 September 2019
Resolution: Vessel found a bad relay and replaced it, tested all sat.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 18 September 2019
Resolved
Vessel must remove both water tanks onboard used to haul water by 19OCT19. Vessel’s Stability letter date Nov 22, 2011 issued by MSC does not allow any deck cargo only Passengers. If company which to continue to hauling water and other cargo submit plans and drawing to MSC for review as per 46 CFR 178.230 (a)(2) and (b).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2019
Resolved 5 December 2019
Resolution: vessel has removed water tank
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 November 2018
Resolved
Provide prove that annual servicing has been completed on both Pre-Engineered fixed gas extinguishing systems or complete annual servicing if it has not been completed.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 November 2018
Resolution: Vessel has had both Pre-Engineered fixed gas extinguishing systems serviced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 November 2018
Resolved
Replace the line for the floating water light and replace the lifeline
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2019
Resolution: Verified lifeline and waterlight line were renewed and properly attached to the life Buoy.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 November 2018
Resolved
3. Provide Alcohol testing equipment onboard for each crew member onboard
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2019
Resolution: Verified test strips were aboard and serviceable.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 1 November 2018
Resolved
Conducted underway abandon ship, man overboard and fire drill with Coast Guard Inspectors prior to carrying passengers
Action required: 705 - Other - as specified
Due 1 May 2019
Resolved 30 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 1 November 2018
Resolved
Vessel must conduct and log drills every month if reasonable, but at least once every three months before getting underway with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2019
Resolution: Verified drills were logged and discussed the details of the regulation with the operator.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 November 2018
Resolved
Replace all expired items in first aid kit
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2019
Resolution: Examined contents of first aid kit and verfied all perishable items were within service dates.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 1 November 2018
Resolved
Repair port side engine room water tight gasket on hatch
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 February 2019
Resolution: Examined port side watertight hatch gaskets. Gaskets were properly seated and malleable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 November 2018
Resolved
Repair exhaust cooling water leak on port side main engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 February 2019
Resolution: Witnessed a satisfactory operational test of the port main engine and associated exhaust piping.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 1 November 2018
Resolved
Fix exhaust lagging on both main engines to protect personal from hot surfaces.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 February 2019
Resolution: Examined exhaust installations for both main engines and verified lagging was installed in required areas.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 November 2018
Resolved
Remove all dead end wire in both engine rooms. Starboard side by aft hatch. Port side by both fwd and aft hatches.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 February 2019
Resolution: Verified all identified dead end wires were properly terminated in a junction box.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 1 November 2018
Resolved
Install permanent draft marks/max loading mark as listed on vessels Stability Letter prior to starting next season
Action required: 705 - Other - as specified
Due 1 April 2019
Resolved 14 March 2019
Resolution: Verified permanent loading marks were applied to the hull as per provided drawing and consistent with the stability letter details for max draft.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 August 2018
Resolved
Repair engine exhaust leak on starboard engine in the area of the turbo.
Action required: 705 - Other - as specified
Due 7 September 2018
Resolved 11 September 2018
Resolution: Vessel repaired tubro leak. tested all sat
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Crankcase
Issued 15 September 2017
Resolved
Repair or renew starboard main diesel engine as a result of catastrophic cylinder/crankcase failure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 11 May 2018
Resolution: Verified vessel's starboard MDE was repaired and installation was satisfactory. Witnessed an operational test.
Operations/Management › Drills/Instruction › Not Conducted
Issued 15 September 2017
Resolved
Drills required to be conducted in the spring.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 18 May 2018
Resolution: Witnessed satisfactory underway fire, man-overboard, and abandon ship drills.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 September 2017
Resolved
Demonstrate the proper operation of the STBD side, FWD masthead, and stern light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 13 August 2018
Resolution: vessel has repaired all mast lights
Engineering › Bilge Water Management System › Pump
Issued 15 September 2017
Resolved
Demonstrate proper operation of all installed bilge pumps.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 11 May 2018
Resolution: Witnessed an operational test of all compartment's bilge pumps.
Engineering › Bilge Water Management System › Not Operational
Issued 15 September 2017
Resolved
Demonstrate proper operation of all bilge high level alarms.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2018
Resolution: Tested all bilge high level alarms all tested sat.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 15 September 2017
Resolved
Renew or replace two excessivley corroded portable extinguishers IWO of ER accesses.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 13 August 2018
Resolution: Vessel has replaced both Portable extinguishers.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 15 September 2017
Resolved
Prove proper operation of both ER pre-engineered fire suppression systems.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 13 August 2018
Resolution: tested both pre-engineered systems, all sat
Fire Fighting › Fire Pumps › Arrangement
Issued 15 September 2017
Resolved
Prove proper operation of the vessel's installed fire pump or provide alternate means
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 13 August 2018
Resolution: tested fire pump all sat.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 15 September 2017
Resolved
Lock out marine sanitation device ovbd discharge when within 3nm of shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 9 November 2017
Resolution: Verified sewage ovbd discharge valve was secured.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 September 2017
Resolved
Provide metal wire/cable supports for main longitudinal wire runs in both hulls.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 13 August 2018
Resolution: wiring has been supported.
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 October 2016
Resolved
Drills required to conducted in the spring.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 1 May 2017
Resolution: Conducted fire, abandon ship, and man overboard drill - all sat.
Stability › Watertight Integrity › General
Issued 4 October 2016
Resolved
Provide gaskets for the port forepeak and port forward engine room deck hatches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 20 October 2016
Resolution: Both hatch gaskets were renewed and appeared serviceable.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 4 October 2016
Resolved
Port engine room FM-200 fire suppression system in excessively corroded. Service or renew bottle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 13 December 2016
Resolution: Verified installation of newly serviced FM-200 bottle. Installation sat, with current servicing sticker affixed to the bottle.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 28 March 2016
Resolved
Repair main deck exterior hatch covers to ensure they are watertight. 46CFR179.360(a)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2016
Resolved 3 May 2016
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 28 March 2016
Resolved
Remove sea chest screens on the bottom of the hull and remove marine growth. 46 CFR 182
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 3 May 2016
Stability › Watertight Integrity › Weathertight Enclosure
Issued 28 March 2016
Resolved
Install means on main deck exterior hatch covers to prevent loss. 46CFR179.360(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 3 May 2016