BRIANA MARIE is a 2004 offshore supply vessel. The Coast Guard has recorded 20 inspections since 2016, most recently in February 2026, along with 23 deficiencies and 3 casualty investigations between 2019 and 2025.
Records from 2016 to 2026. Most recent: inspection, 25 February 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Registered dimensions (L × B × D)126.6 ft × 32.0 ft × 11.5 ft
Registered tonnagegross 95 / net 64
ITC dimensions (L × B × D)126.6 ft × 32.0 ft × 11.5 ft
ITC tonnagegross 375 / net 112
BuilderMASTER MARINE INC · BAYOU LA BATRE, AL, UNITED STATES · built 2004
DocumentationValid · issued 23 July 2026 · expires 31 August 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it375 - Convention (Subpart B), Gross Ton 95 - Regulatory (Subpart C or D), Gross Ton 112 - Convention (Subpart B), Net Ton 64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 9 April 2024Resolved
Suitable hand covers, guards, or rails must be installed on each exposed and dangerous place, such as gears of rotating machinery, and hot surfaces. STBD engine had missing portion of guard for the front flywheel.
46 CFR 127.330
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
Resolution: Guards and covers installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 April 2024Resolved
Each cable and wire must— Be supported so as to avoid chafing or other damage. Wires and cable were not secured or supported on the upper deck. Support cable and wires to provide support and secureness to avoid damage.
46 CFR 129.340(b)(4)
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
Resolution: Support cables added.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 April 2024Resolved
At each inspection for certification, the marine inspector determines whether the tests and inspections required by § 132.350 of this subchapter have been performed. Vessel had portable fire extinguishers services 4/8/2024. One fire extinguisher in the engine room was missed and had an expired inspection tag. Provide proof of service and tag for extinguisher.
46 CFR 126.450
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
Resolution: Extinguisher was serviced.
A person may not engage in a position required to hold a MMC unless that individual maintains a current medical certificate. Mate medical certificate was expired.
Vessel restricted to voyages less than 12 hours until mate with proper documentation is on board.
Action required: 705 - Other - as specified
Due 27 April 2023
Resolved 25 April 2023
Resolution: New mate with proper credentials and valid medical certificate was provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 April 2021Resolved
46 CFR 129.220 (c): Recepticle outlets of the type providing a grounded pole or a spcific direct-current polarity must be of a configuration that does not permit improper connection. Engine room outlet outboard of alarm panel is missing a cover plate. Replace to the satisfaction of the Coast Guard inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2021
Resolved 27 April 2021
Resolution: [name withheld] received objective evidence from vsl rep via email that all defs have been corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 20 April 2021Resolved
46 CFR 129.410 (a): Each globe, lens, or diffuser of a lighting fixture must have a high-strength guard or be made of high-strength material. Port storage overhead light had a cracked lens and was hanging from the overhead. Repair/replace to the satisfaction of the Coast Guard.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2021
Resolved 27 April 2021
Resolution: [name withheld] received objective evidence from vsl rep via email that all defs have been corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 20 April 2021Resolved
46 CFR 127.330: Suitable hand covers, guards, or rails must be installed on each exposed and dangerous place, such as gears of rotating machinery, and hot surfaces. Center SSDG flywheel guard was missing. Replace to the satisfation of Coast Guard inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2021
Resolved 27 April 2021
Resolution: [name withheld] received objective evidence from vsl rep via email that all defs have been corrected.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 20 April 2021Resolved
46 CFR 129.100: This part contains requirements for the design, construction, and instillation of electrical equipment and systems including power sources, lighting, motors, miscellaneous equipment, and safety systems. General alarm in the engine room is missing handle for remote activation. Replace to the satisfaction of the Coast Guard inspector.
27Apr2021 [name withheld] received objective evidence from vsl rep via email that all defs with the exception of the GA in the engine room were corrected. Updated deficiencies in activity. Researched GA requirement in E/R in Sub-L there are multiple internal comms options. Reached out to vsl rep to see what comms were available in E/R that might meet the requirement.
Inspection Continues
//[name withheld]//
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2021
Resolved 27 April 2021
Resolution: [name withheld] received objective evidence from vsl rep via email that all defs have been corrected.
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 20 April 2021Resolved
46 CFR 130.130 (f): The steering gear must be designed so that transfer from the main steering gear or its control to the auxiliary steering gear or its control can be achieved rapidly. Any tools or equipment necessary for transfer must be readily available. Instructions for transfer must be posted. Emergency steering did not have posted instructions and the rudder angle indicator was painted over.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2021
Resolved 27 April 2021
Resolution: [name withheld] received objective evidence from vsl rep via email that all defs have been corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 April 2021Resolved
46 CFR 111.05-21(b): There must be ground detection for each Ships service power system. Switchboard ground detection was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2021
Resolved 27 April 2021
Resolution: [name withheld] received objective evidence from vsl rep via email that all defs have been corrected.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 20 April 2021Resolved
33CFR155.720- The operator of a vessel shall provide transfer procedures; The vessel’s transfer procedures were unreadable at the fuel pump, provide transfer procedures per 33CFR155.720.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2021
Resolved 27 April 2021
Resolution: [name withheld] received objective evidence from vsl rep via email that all defs have been corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 April 2021Resolved
46CFR130.460(a)(5)- A visible and audible alarms must be installed at the pilothouse to indicate the following: low lube-oil pressure for each main propulsion engine; Both MDE L/O psi gauges were inoperable; provide proper operation to attending USCG marine inspector
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2021
Resolved 27 April 2021
Resolution: [name withheld] received objective evidence from vsl rep via email that all defs have been corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 20 April 2021Resolved
Each muster station and embarkation station must be adequately illuminated by lighting supplied from the emergency source of electric power; Embarkation lights did not adequately illuminate the embarkation area while on emergency power; provide proper operation to attending USCG inspector 46CFR133.110(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 27 April 2021
Resolution: [name withheld] received objective evidence from vsl rep via email that all defs have been corrected.
Fire Fighting › Fixed Deck Foam System › Monitors
Issued 7 May 2018Resolved
Provide proper operation of fire monitor. Prior to operating as EEP/Standby Vessel.
Action required: 705 - Other - as specified
Resolved 25 April 2023
Resolution: Removed Standby endorsement from COI
Provide proper replacement of watertight door gasket leading to engine room, make watertight hatch leading to engine room watertight.
Action required: 10 - Deficiency Rectified
Resolved 8 May 2018
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 4 October 2017Resolved
1. Re-Install Pressure Vacuum Valves on #1 Port & STBD and #2 Port & STBD Methanol tanks to satisfaction of attending U.S.C.G. Inspector prior to carriage of Methanol.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 October 2017
Resolved 25 April 2023
Resolution: Removed methanol conditions of carriage from COI
Condition: Improper/Lack of Maintenance
Due 13 February 2017
Resolved 15 February 2017
Resolution: Lagging replaced
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 February 2017Resolved
Replace 3 spliced wires on port MDE with permanent wires
Condition: Improper/Lack of Maintenance
Due 13 February 2017
Resolved 15 February 2017
Resolution: Spliced wires replaced with proper wiring
Electrical › Electric Supply System (service) › Battery Charger
Issued 6 February 2017Resolved
Provide proper permanent wiring for engine room battery chargers
Condition: Improper Installation
Due 13 February 2017
Resolved 15 February 2017
Resolution: Permanent wiring connected to battery charger
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 6 February 2017Resolved
Floating Electric Waterlight not operating
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2017
Resolution: Battery replaced prior to completion of inspection and light operating properly
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 February 2017Resolved
Two (02) lifebuoy lights not operating
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2017
Resolution: Batteries replaced in both lifebuoy lights prior to completion of inspection
8 August 2019Routine · role: Involved in a Marine Casualty · activity 6790720
15 June 2020Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6980924
31 January 2025Routine · role: Involved in a Marine Casualty · activity 8079425
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.