Records from 2004 to 2026. Most recent: inspection, 4 March 2026.
Inspection history · 53
4 March 2026
Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8319845
6 January 2026
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8291183
7 July 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8178332
13 March 2025
Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8094001
27 February 2025
Examination of Repairs · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8090131
30 September 2024
In-Service Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8012075
28 September 2024
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8314301
7 August 2024
In-Service Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7976524
17 April 2024
Administrative Inspection · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7897105
6 March 2024
Administrative Inspection · In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7875197
1 May 2023
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7679007
24 April 2023
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7674635
15 November 2022
In-Service Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7595074
19 August 2022
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7537992
23 May 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7457587
19 May 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7201271
2 December 2020
Deficiency Check · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7105191
4 September 2020
Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7053963
31 July 2020
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7020782
3 April 2019
Examination of Repairs · Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6658426
1 April 2019
Administrative Inspection · In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6653766
1 April 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6655739
20 March 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6647321
12 February 2019
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6624543
27 August 2018
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6524579
8 May 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6408814
28 February 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6363205
28 September 2017
In-Service Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6276977
25 May 2017
Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6155566
25 May 2017
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6208140
25 April 2017
Type not recorded
No type recorded · Suspension & Revocation National Center of Expertise · Activity 6132423
7 February 2017
Periodic Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6083814
5 March 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5828678
26 February 2016
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5822467
24 November 2015
Drydock Exam · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5769369
3 August 2015
Examination of Repairs · Damage Survey · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5206773
15 July 2015
Damage Survey · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5186053
13 July 2015
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5190476
21 October 2014
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5009560
6 August 2014
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4947903
6 August 2014
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5050335
2 August 2014
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4945869
4 March 2014
Administrative Inspection · In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4811653
26 February 2012
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4269607
21 February 2012
Drydock Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4248428
6 January 2012
Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4220353
8 February 2011
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3942621
24 September 2010
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3857908
25 February 2010
Deficiency Check · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3686539
12 February 2009
COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3416522
11 July 2007
Initial Construction-Excluding Oversight · Internal Structural Exam · Initial Certification · Drydock Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2991620
28 May 2004
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2749457
21 January 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2070359
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 March 2025
Resolved
Machinery and equipment installed on each vessel
must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
Received report of steering gear ram ball joint severed during operation.
Replace steering gear ram ball joint to the satisfaction of a CG Marine Inspector prior to carrying passengers.
46 CFR 182.100
701 C
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2025
Resolution: Inspected new steering ball joint. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 September 2024
Resolved
A VESSEL MUST HAVE A MAIN STEERING GEAR THAT IS CAPABLE OF STEERING THE VESSEL AT ALL SERVICE SPEEDS. THE VESSEL EXPERIENCED A CASUALTY ON 28SEP2024 AT APPROXIMATELY 1445 LOCAL, RESULTING IN THE LOSS OF STEERING RESPONSIVENESS, CAUSING THE OPERATOR TO MAKE A RETURN TO THE PIER UTILIZING THE TWIN PROPULSION SYSTEM. EMAIL NOTIFICATION WAS MADE TO SECTOR HG IO's AT APPROXIMATELY 2054 LOCAL TIME ON 29SEP2024.
VESSEL IS PROHIBITED FROM OPERATIONS UNTIL A SATISFACTORY SEA TRIAL HAS BEEN PERFORMED IN THE PRESENCE OF A CG MARINE INPSECTOR.
46CFR182.610
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2024
Resolution: Hydraulic line replaced and sea trials conducted to satisfaction of MI.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 March 2024
Resolved
he following spaces must be equipped with a fixed gas fire extinguishing system, in compliance with § 181.410, or other fixed fire extinguishing system specifically approved by the Commandant, except as otherwise allowed by paragraph (b) of this section:
A space containing propulsion machinery; A space containing an internal combustion engine of more than 37.3 kW (50 hp);A space containing machinery powered by gasoline or other fuels having a flash point of 43.3 °C (110 °F) or lower.
Vessel's fire detection system is inoperable. New fire detection system and alarm panel have been installed but has not been approved by MSC.
After successful operational test of new fire detection system and alarm panel, vessel may resume operations with the addition of one extra crew-member while carrying passengers.
This restriction will remain in effect until the new fire detection system is approved by MSC.
46 CFR 181.400
705 C
Action required: 705 - Other - as specified
Due 27 March 2024
Resolved 26 March 2024
Resolution: Received MSC approval letter for new installed fire detection system.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 May 2023
Resolved
Each life jacket must be marked with Type I retroreflective material approved in accordance with § 164.018 in subchapter Q of this chapter, or other
standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16), ‘‘Use and Fitting Of Retro- Reflective Materials on Life-Saving Appliances.’’
Adult and child size life jackets found with washed out retro-reflective tape.
Replace retro-reflective tape on all identified life jackets.
46 CFR 185.614(h)
16 C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2023
Resolved 11 May 2023
Resolution: New life jackets and retro tape installed on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 1 May 2023
Resolved
Machinery and equipment installed on each vessel
must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
Received report of steering gear ram ball joint severed during operation. CG Marine Inspector verified damaged steering gear ball joint.
Replace steering gear ram ball joint to the satisfaction of a CG Marine Inspector prior to carrying passengers.
46 CFR 182.100
701 C
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2023
Resolved 4 May 2023
Resolution: New ball joint installed.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 23 May 2022
Resolved
U.S. Vessels less than 50 GT which are navigated not more than 1,000 feet from the nearest land are exempt.
Prior to operating greater than 1,000 feet from land, prove proper operation of VHF Radio.
47 CFR 80.933(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 24 May 2022
Resolution: Video evidence of proper operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 May 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
Vessel restricted to 139 persons.
46 CFR 180.71(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 22 June 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 23 May 2022
Resolved
A hatch cover must be attached to the hatch frame or coaming.
Attach hatch cover for #1 compartment to its frame within 30 days.
46 CFR 179.360(b)(2)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2022
Resolved 22 June 2022
02 - Structural Conditions › N/A - No Subsystem › Marking of IMO number
Issued 23 May 2022
Resolved
The number must be permanently affixed to the vessel.
Permanently affix the offician number within 30 days.
46 CFR 67.121
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2022
Resolved 22 June 2022
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 August 2020
Resolved
On a vessel of not more than 65 feet in length carrying more than 49 passengers, the minimum capacity of the fire pump must be 50 gallons per minute at the pressure of not less than 60 psi at the pump outlet. The fire pump was inoperable.
46 CFR 181.300(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 August 2020
Resolution: Powered pump on engine was repaired. Bilge suction and fire pump pressure was tested satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 11 August 2020
Resolved
The vessel must be fitted with a Federal Communications Commission (FCC) type general marine radar system for surface navigation with a radar screen mounted at the operating station. The radar was inoperable.
46 CFR 184.404(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 September 2020
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 August 2020
Resolved
The requirements in this paragraph are applicable to any vessel equipped with AIS. (2) The AIS must be maintained in effective operating condition. The AIS was inoperable.
33 CFR 164.46(d)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 September 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 February 2019
Resolved
A vessel must be provided with bilge pumps. During inspection it was noted that primary bilge pumps were not operational. Prove proper operation prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2019
Resolution: Bilge Pump piping system was tested SAT.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 21 February 2019
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate high water level. During Inspection it was noted that high water alarms were not operating properly. Prove proper operation prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2019
Resolution: Water level indicator was tested, All SAT.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 21 February 2019
Resolved
A self priming, power driven fire pump must be installed on each vessel of not more than 65 feet that carries more than 49 passengers. During inspection it was noted that the fire pump was not operational. Prove proper operation prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2019
Resolution: Flex hose was replaced with fixed piping, System tested, All SAT.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 21 February 2019
Resolved
The master in charge of a ship shall ensure that the ship is not operated unless a garbage management plan is on board. During inspection it was noted that the vessel does not have a garbage management plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 March 2019
Resolution: Garbage plan posted
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 21 February 2019
Resolved
A durable placard must be posted next to all radio telephone installations with emergency broadcast instructions and information, specific to the individual vessel. During inspection no emergency broadcast placard was present.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 March 2019
Resolution: Placard posted
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 February 2019
Resolved
All fuel tanks must be electrically bonded to a common ground. During inspection it was noted that the rubber hose between the fill neck and filling port of fuel tank were not bonded. Additionally, the rubber hose requires replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 March 2019
Resolution: Fuel tanks were bonded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 February 2019
Resolved
A positive shut off valve must be installed at the hull penetration of a submersible bilge pump. During inspection it was noted that there were no valves present in the submersible bilge pump lines of all compartments.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 22 March 2019
Resolution: Shutoff valves were installed
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 25 May 2017
Resolved
Vessel would not disengage from astern propulsion.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2017
Resolved 25 May 2017
Resolution: Diesel technitions were aboard testing software and found zero issues. Vessel operated normally during test.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 5 March 2016
Resolved
Vessel experienced loss of propulsion, propulsion machinery must be suitable in type and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel is not authorized to carry passengers until propulsion machinery has been successfully repaired and sea trials are conducted to the satisfaction of the attending CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2016
Resolution: Attended vessel, inspected repairs and witnessed satisfactory sea trials.
Construction/Loadline › Hull › Weld
Issued 3 August 2015
Resolved
Broken intermediate strut on the port shaft.
Action required: 705 - Other - as specified
Resolved 4 August 2015
Resolution: Welded strut back to hull.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 July 2015
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed, 46CFR182.200. Vessel experienced starboard engine shutdown and shall have a certified marine technician attend vessel attesting to cause and repair of starboard main engine.
Action required: 705 - Other - as specified
Resolved 17 July 2015
Resolution: Marine Inspectors witnessed satisfactory sea trials.
Engineering › Diesel Engine (propulsion-direct drive) › Bearing
Issued 8 August 2014
Resolved
Component Unknown. engine failure/shutdown cause is unknown and the vessel company was going to schedule technicians to visit the vessel and conduct repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 September 2014
Resolved 8 August 2014
Resolution: Engines found to be working in satisfactory condition upon detection of ground in wiring system, sea trial completed.
Fire Fighting › Fire Pumps › Gears
Issued 25 February 2010
Resolved
Repair and prove proper operation of the fire pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 February 2010
Resolution: Fire pump repaired.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 11 July 2007
Resolved
Complete the Documentaion process and the DOC on board.
Action required: 705 - Other - as specified
Due 18 May 2008
Resolved 27 October 2008
Resolution: The DOC is onboard.
Documentation › Certificates/Documents › FCC SSL
Issued 11 July 2007
Resolved
Provide a valid FCC Station Licence.
Action required: 705 - Other - as specified
Due 18 May 2008
Resolved 27 October 2008
Resolution: FCC Station licence provided.
Documentation › Certificates/Documents › Stability Letter
Issued 11 July 2007
Resolved
Post the Stbility Letter when provided.
Action required: 705 - Other - as specified
Due 18 May 2008
Resolved 27 October 2008
Resolution: The stability letter is posted onboard.
Electrical › Electric Supply System (service) › Cable
Issued 11 July 2007
Resolved
Complete the approval process for electrical plan review.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2008
Resolved 12 February 2009
Resolution: Plan review completed.