MAURY USCG vessel records
← All vessels

PANAMAX BREEZE

PANAMAX BREEZE is a 2004 freight ship. The Coast Guard has recorded 1 inspection in 2023, along with 2 deficiencies.

Records in 2023. Most recent: inspection, 10 July 2023.

Built
2004
Last inspected
10 July 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 July 2023
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9278430
686127
Flag
ISLE OF MAN
Maury page id
psix-686127

Documentation record

Tonnage as PSIX records it25830 - Convention (Subpart B), Net Ton
76343 - Dead Weight, Ton
86791 - Displacement, Ton
39802 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 1

10 July 2023 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7716498

Deficiency record · 2

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 July 2023 Resolved
The following functional requirements shall be met: means shall be provided to control flammable liquids. PSCO observed active fuel leak from fuel oil heater in purified space. 74 SOLAS (04 Cons.) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2023
Resolved 10 July 2023
Resolution: Received Class Report attesting oil seal had been changed.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 10 July 2023 Resolved
Each operation described in... this regulation shall be fully recorded without delay in the Oil Record Book Part 1, so that all entries in the book appropriate to that operation are completed. PSCO observed OWS entries exceeding max throughput on multiple dates. MARPOL Annex I/17.4
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 10 July 2023
Resolved 10 July 2023
Resolution: Received Class Report attesting OWS record times were corrected in ORB.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.