Records from 2005 to 2025. Most recent: inspection, 23 September 2025.
Inspection history · 34
23 September 2025
COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8239282
23 January 2025
Internal Structural Exam · Drydock Exam · Cargo Tank Internal
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8069200
21 November 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8037264
20 November 2023
Periodic Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8017768
1 June 2023
Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7703959
11 January 2023
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7619618
27 October 2021
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7341012
14 October 2020
Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7077448
3 February 2020
Deficiency Check · Construction Oversight · Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6899460
30 October 2018
Internal Structural Exam · Administrative Inspection · Periodic Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6571118
27 November 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6313652
25 October 2016
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6027320
20 October 2015
Internal Structural Exam · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5745932
12 November 2014
Examination of Repairs · Deficiency Check · Administrative Inspection · Annual Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5022054
24 October 2013
Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4740559
15 November 2012
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4484535
10 May 2012
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4307810
5 December 2011
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4202097
25 October 2010
Internal Structural Exam · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3859152
21 January 2010
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3666766
4 January 2010
Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3657205
26 June 2009
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3514533
8 June 2009
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3500922
17 November 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3358983
27 February 2008
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3154898
30 October 2007
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3089352
2 October 2007
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3071538
21 February 2007
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2875385
26 December 2006
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2846201
11 October 2006
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2798291
25 October 2005
MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2522027
13 June 2005
Deadweight Survey · Internal Structural Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2382668
7 June 2005
Hull Examination · COI Inspection · Plan Review (Other than "T")
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2382685
10 January 2005
Security Plan Amendment Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2271885
02 - Structural Conditions › N/A - No Subsystem › Marking of IMO number
Issued 23 September 2025
Resolved
For vessels having a square bow, the name of the vessel must be marked on some clearly visible exterior part of the bow in a manner to avoid obliteration. The name and hailing port must be marked on some clearly visible exterior part of the stern in clearly legible letters not less than four inches in height. The barge is missing name and hailing port markings. 46 CFR 67.123(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 December 2025
Resolved 8 January 2026
Resolution: Operator emailed photo evidence of corrections. Photo uploaded to documents.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 23 September 2025
Resolved
The owner, master, or person-in-charge of a tank vessel must ensure that portable and semi-portable extinguishers are inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 31.01-2) as specified in paragraphs (a)(1) through (4) of this section. Fire service report is missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2025
Resolved 8 January 2026
Resolution: Operator emailed photo evidence of fire servicing. Photo uploaded to documents.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 November 2024
Resolved
The owner, master, or person-in-charge of a tank vessel must ensure that portable extinguishers are inspected and maintained in accordance with NFPA 10. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records has not been properly maintained, a qualified servicing facility must perform the required inspections, maintenance procedures, and hydrostatic pressure tests. A tag issued by a qualified servicing organization, and attached to each extinguisher, may be accepted as evidence that the necessary maintenance procedures have been conducted. Portable extinguisher did not have proof that maintenance has been completed IAW NFPA 10.
46 CFR 31.10-18(a)(4)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 27 November 2024
Resolution: Received photo with sat proof of fire servicing.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 November 2024
Resolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Waterlight attached to life ring buoy was not operational.
46 CFR 199.190(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 12 December 2024
Resolution: Verified operation of waterlight
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 November 2024
Resolved
Each vessel must carry lifebuoys approved under approval series 160.150. FWD lifebuoy retro reflective tape was deteriorated. Replace tape in kind.
46 CFR 199.70(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2024
Resolved 27 November 2024
Resolution: received photo showing sat replacement of tape
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 1 June 2023
Resolved
If, during an internal structural examination, damage or deterioration to the structural members is discovered, the OCMI may require the vessel to effect permanent repairs. Vertical frame in void 3 had fractured weld and portion of framing was separated from starboard sideshell. Fracture is located midway down the frame, approximately 5 frames aft of starboard access ladder. Make permanent repairs to the satisfaction of marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2023
Resolved 3 August 2023
Resolution: Verified sat repair.
01 - Certificates & Documentation › 013 - Documents › Shipboard marine pollution emergency plan for NLS
Issued 3 February 2020
Resolved
ALL VESSELS ARE REQUIRED TO MAINTAIN AN APPROVED VESSEL RESPONSE PLAN.
VESSEL'S ARRPOVAL LETTER WAS EXPIRED.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 October 2020
Resolution: Verified valid response plan in place.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 February 2020
Resolved
VESSEL IS REQUIRED TO MAINTAIN AN APPROVED SECURITY PLAN.
SECURITY PLAN APPROVAL LETTER IS EXPIRED.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 October 2020
Resolution: Verified security plan approval is current.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 February 2020
Resolved
INCORPORATION BY REFERENCE: NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 10. AN ANNUAL EXTERNAL VISUAL EXAMINATION OF ALL FIRE EXTINGUISHERS SHALL BE MADE.
VESSEL'S FIRE EXTINGUISHER DID NOT HAVE LOG OF COMPLETED ANNUAL INSPECTION.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2020
Resolved 22 May 2020
Resolution: Received documentation of completed annual inspection.
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 30 October 2018
Resolved
Cargo tanks in which Grade D or E liquids only are to be transported shall be fitted with gooseneck vents and flame screens. All goosenecks on the barge are clogged with mud/grime, completely covering the flame screens.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 October 2018
Resolved 30 October 2018
Resolution: Crew cleaned out all gooseneck vents during inspection.
Construction/Loadline › Hull › Bottom Plating
Issued 31 January 2015
Resolved
Vessel may not condut cargo operations until a dry-dock exam has been conducted.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2015
Operations/Management › Cargo Transfer/Lightering › Person in Charge Presence/Supervision
Issued 12 November 2014
Resolved
Provide proof that transfers of oil are being conducted by a PIC meeting the requirements of 46CFR13
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 October 2015
Operations/Management › Cargo Transfer/Lightering › Person in Charge Presence/Supervision
Issued 12 November 2014
Resolved
Provide list of persons currently designated in charge of transfer operations IAW 33CFR155.820
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 October 2015
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 12 November 2014
Resolved
Provide onboard complete transfer procedures IAW 33CFR155.720-760
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 December 2014
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 12 November 2014
Resolved
Provide approved Tank Vessel Response Plan IAW 33CFR155.1010-1030 & .1040
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 December 2014
Deck/Cargo › Cargo Stowage › General
Issued 12 November 2014
Resolved
Provide proof that on deck cargo vents meet 46CFR32.55-25 (b) or request reduction of vessel carrying grades to Dor E only.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 December 2014
Resolution: Revised COI to allow only grades D-E cargoes.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 12 November 2014
Resolved
Provide proof of annual tightness test for cargo discharge piping at the MAWP IAW 46CFR35.35-70(d).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 January 2015
Resolution: Witnessed test
Deck/Cargo › Cargo Stowage › General
Issued 12 November 2014
Resolved
Provide proof that the company complies with benzene regulations in 46CFR197 Part C or request COI restriction from carrying benzene containing products.
Action required: 705 - Other - as specified
Resolved 29 December 2014
Resolution: Issued revised COI with restriction from Benzene Cargos in excess of .5%
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 November 2014
Resolved
Remove the non-intrinsically safe flood lights from the mast (approx. 5' from tank vents). 46CFR111.105-3 & 5
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 December 2014
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 12 November 2014
Resolved
PROVIDE VALID CERTIFICATE OF FINANCIAL RESPONSIBILITY. 33CFR138.15
Due 5 May 2015
Resolved 20 July 2015
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 25 October 2010
Resolved
Provide name and hailing port on vessel transom - 46 CFR 67.123.
Condition: Improper Installation
Due 25 November 2010
Resolved 23 November 2010
Resolution: Installed name on hailing port.
Electrical › Lighting (service) › Lighting Fixture
Issued 25 October 2010
Resolved
Provide plans for approval of heating and lighting systems in deck house or remove from barge and properly dead end all wires 46 CFR 31.35-1.
Condition: Design Flaw
Due 25 November 2010
Resolved 23 November 2010
Resolution: Removed the system.
Electrical › Electrical Distribution System (service) › Cable
Issued 25 October 2010
Resolved
Properly support loose wires in the below deck tanks 46 CFR 111.60-5.
Condition: Improper/Lack of Maintenance
Due 25 November 2010
Resolved 23 November 2010
Resolution: Installed new brackets.
Deck/Cargo › Holds/Tanks › Cargo Tank Arrangement/Size
Issued 17 November 2008
Resolved
Found that barge was not operating within the limitations listed on the COI and Stability Letter by utilizing the below deck tanks to transport sewage and gray water. Company shall cease carrying sewage and gray water as prohibited by COI and Stability Letter.
Due 18 November 2008
Resolved 17 November 2008
Resolution: Corrected on the spot. [name withheld] informed Company Rep. [name withheld] that they are violating the COI and Stability letter by carrying sewage or gray water in the below deck tanks.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 17 November 2008
Resolved
COI and Certificate of Documentation were not on board as required. Provide original COI and COD onboard barge.
Due 18 November 2008
Resolved 17 November 2008
Resolution: Corrected on the spot.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 29 November 2006
Resolved
Hydro cargo tank piping to 1.5 times the MAWP.
Due 29 December 2006
Resolved 26 December 2006
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 29 November 2006
Resolved
Properly change Certificate of Documentation (COD) to state correct service of Barge (Tank Barge).
Due 31 July 2007
Resolved 2 October 2007