PALMETTO BREEZE

PALMETTO BREEZE is a 2004 passenger vessel (inspected). The Coast Guard has recorded 36 inspections since 2003, most recently in June 2026, along with 64 deficiencies and 1 casualty investigation in 2021.

Records from 2003 to 2026. Most recent: inspection, 8 June 2026.

Built
2004
Last inspected
8 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDP8627
698244
Flag
UNITED STATES
368392170
Maury page id
psix-698244

Inspections, by type

…with no type recorded3
Years with a record 21 calendar years (2003–2026)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)55.0 ft × 30.0 ft × 8.0 ft
Registered tonnagegross 29 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA ISLAND BOATWORKS INC · CHARLESTON, SC, UNITED STATES · built 2004
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationTwin Hull
Hailing portCHARLESTON, SC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29 - Simplified, Gross Ton
23 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP8627MMSI 368392170 · active · compulsorily equipped · granted 29 October 2024, expires 29 October 2034
WDC5386MMSI 367040270 · expired · compulsorily equipped · granted 28 February 2015, cancelled 14 June 2025
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

TEASER 2 Passenger (Inspected) · MISLE 3931 · 12 November 2016 · activity 6042392SHAYNA MICHELLE Commercial Fishing Vessel · MISLE 175730 · 12 November 2016 · activity 6042392SC1849BT Passenger (Uninspected) · MISLE 1426960 · 12 November 2016 · activity 6042392

Inspection history · 36

8 June 2026 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8395203
16 January 2026 Drydock Exam · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8296745
17 January 2025 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8065111
18 September 2024 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8004958
12 February 2024 Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7864482
18 December 2023 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7840264
14 December 2022 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7609182
17 February 2022 Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7397808
30 September 2021 COI Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7322205
23 September 2021 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7323802
28 June 2021 Damage Survey · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7238069
27 June 2021 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7238675
10 December 2020 DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7109791
13 February 2020 Administrative Inspection · Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6908263
5 December 2019 Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6874454
28 November 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6588570
28 February 2018 Drydock Exam · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6363044
15 February 2018 Administrative Inspection · Drydock Extension
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6359302
17 November 2017 DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6310919
12 November 2016 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6042392
22 September 2016 DAPI Audit · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6001311
17 February 2016 Administrative Inspection · Hull Examination · Drydock Exam · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5817699
13 November 2015 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5762950
14 October 2014 Deficiency Check · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5005050
7 August 2014 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4946750
4 March 2014 Drydock Exam · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4811868
18 June 2012 Hull Examination · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4347640
19 September 2011 COI Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4149067
21 October 2008 Deficiency Check · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3348765
19 September 2008 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3328150
30 June 2008 Deficiency Check · Plan Review "T" Boat · Internal Structural Exam · In-Service Inspection · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3252301
27 September 2007 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3067730
26 June 2006 Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2691750
12 May 2005 Re-Inspection · Administrative Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2355622
15 July 2004 Deficiency Check · Initial Certification
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2134092
10 November 2003 Initial Construction-Excluding Oversight
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2086327

Deficiency record · 64

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 June 2026 Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Rather than shut down the engines in the space, both engines are approved draw intake air from outside the space protected through non-combustible hoses. The starboard engine intake hose has been replaced with combustible ducting which would melt in the event of a fire. Rectify deficiencies within 05 days.
Action required: 705 - Other - as specified
Due 15 June 2026
Resolved 11 June 2026
Resolution: Vessel sent pictures of satisfactory intake arrangement.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 10 June 2026 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. VHF radio has the incorrect MMSI. Correct prior to sailing greater than 1000 feet from shore.
Action required: 705 - Other - as specified
Resolved 30 July 2026
Resolution: Vessel provided updated Safety Radiotelephony certificate
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 10 June 2026 Resolved
A vessel of not more than 19.8 meters (65 feet) in length must have a collision bulkhead if it carries more than 49 passengers. Collision bulkhead on both hulls have multiple penetrations for cables which have not been made watertight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2026
Resolved 15 July 2026
Resolution: Vessel owner was on board and was able to explain that the bulkhead noted was not the Collision bulkhead and the cables that penetrated the current bulkhead met requirements for the space.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 June 2026 Resolved
When, in accordance with § 178.210 of this chapter, a vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. If posting is impracticable, the stability letter must be kept on board in a weathertight container readily available for use by the crew and display to passengers and others on request. Vessel did not have the signed stability letter posted or stored on the vessel at the time of the inspection. MI's printed off a new stability letter and provided it to the vessel.
Action required: 10 - Deficiency Rectified
Resolved 10 June 2026
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 June 2026 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. You must contact the cognizant OCMI to schedule an inspection at a time and place which he or she approves. No written application is required. Vessel failed to schedule annual inspection required no later than 03 June 2026.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 June 2026
Resolution: MI's conducted satisfactory annual inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 June 2026 Resolved
In systems and applications where flexible hoses are permitted to be clamped, double hose clamping is required where practicable. Multiple sections, primarily in the starboard hull, of the bilge system flexible hose piping is only single clamped.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2026
Resolved 15 July 2026
Resolution: MI's visited vessel and witnessed addition of missing hose clamps.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 7 March 2025 Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. The ship's propulsion engines, which currently intake air from the protected space, do not automatically shutdown upon activation of the pre-engineered fixed gas fire extinguishing system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 April 2025
Resolved 28 May 2025
Resolution: O/O modified engines to intake air from outside the space protected by the pre-engineered fixed firefighting system.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 3 March 2025 Resolved
A vessel must be provided with a main steering gear that is capable of steering the vessel at all service speeds. Vessel's steering gear is inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2025
Resolution: Appropriate repairs completed and tested in the presence of USCG Inspectors.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 March 2025 Resolved
The design, materials, and construction of booms and standing rigging on a sailing vessel must be suitable for the intended service. Mainsail aft carrier is cracked. Vessel restricted from using main sail until repairs have been made.
Action required: 705 - Other - as specified
Resolved 28 March 2025
Resolution: Crack on the carrier was satisfactorily welded.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 March 2025 Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of non-combustible materials with no openings in the sides or bottom. Vessel has combustible plastic trash cans on deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2025
Resolved 7 March 2025
Resolution: O/O replaced waste receptical with a metal can.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 March 2025 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. Reflective tape on multiple life jackets needs to be replaced
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2025
Resolved 28 March 2025
Resolution: MI's spot checked multiple life jackets which all had new type 1 retroreflective material taped onto them.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 March 2025 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Fuel shutoff valves were not marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2025
Resolved 28 March 2025
Resolution: Fuel shutoff valves are marked in accordance with 185.608.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 3 March 2025 Resolved
Man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Man overboard drills were not logged.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2025
Resolved 26 April 2025
Resolution: Sector Charleston received a copy of the vessel logbook with drills logged inside.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 3 March 2025 Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Fire drills were not logged.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2025
Resolved 26 April 2025
Resolution: Sector Charleston received a copy of the vessel logbook with drills logged inside.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 March 2025 Resolved
Each floating waterlight must be approved in accordance with 46 CFR 161.010 or another standard specified by the Commandant. Waterlight must have energizer L91 batteries in align with its type approval. Limited to day time operations
Action required: 705 - Other - as specified
Resolved 7 March 2025
Resolution: Appropriate battery installed in the waterlight.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 3 March 2025 Resolved
Marine employers may form or otherwise use sponsoring organizations to conduct random chemical testing. Company has applied for but has not been issued DAPI letter at the time of the inspection. 46 CFR 16.230(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2025
Resolved 26 April 2025
Resolution: Sector Charleston received a copy of the vessel's DAPI enrollment.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 17 January 2025 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. You must contact the cognizant OCMI to schedule an inspection at a time and place which he or she approves. No written application is required. Vessel failed to schedule annual inspection required no later than 28Dec2024. 46 CFR 176.500(b)(1)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 March 2025
Resolution: Completed COI Inspection
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 December 2022 Resolved
On a vessel of not more than 65 feet in length carrying more than 49 passengers, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge. The vessel's fire pump did not reach 60 psi. Vessel restricted to no more than 49 passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2023
Resolved 18 January 2023
Resolution: Attended the vessel for def check; pump operation satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 December 2022 Resolved
Each nozzle must be of corrosion-resistant material and be capable of being changed between a solid stream and a spray pattern. A nozzle on a vessel of not more than 65 feet in length carrying more than 49 passengers, must be of a type approved in accordance with approval series 162.027; or Be of a type recognized by the Commandant as being equivalent in performance. The nozzle was not capable of changing stream and was not of an approved type.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2022
Resolved 18 January 2023
Resolution: Attended the vessel for def check; nozzle operated satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 December 2022 Resolved
Each life jacket must be marked with Type I retroreflective material. The retroreflective material on the life jackets was worn.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2022
Resolved 29 December 2022
Resolution: Video provided of satisfactory life jackets
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 14 December 2022 Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. The vessel's compass was not illuminated.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2022
Resolved 29 December 2022
Resolution: Image provided of satisfactory installed compass
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 30 September 2021 Resolved
The fire pump outlet must be fitted with a gauge. The gauge on the port engine for the fire pump was not working.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2021
Resolved 30 September 2021
Resolution: Guage was replaced and tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 September 2021 Resolved
[electric submersible bilge pump] A positive shutoff valve is installed at the hull penetration for the overboard. The positive shutoff valve was frozen and could not be closed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2021
Resolved 30 September 2021
Resolution: Positive shufoff valve was replaced.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 30 September 2021 Resolved
The Master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of a fire, heavy weather, or man overboard conditions. The required emergency instructions were not on the vessel at the time of the inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2021
Resolved 30 September 2021
Resolution: Emergency instructions were printed and placed on board.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 10 December 2020 Resolved
Vessels operating solely within 20 nm of land must be equipped with a VHF-DSC radiotelephone installation. Vessel's VHF does not have DSC function. Vessel restricted to 1000ft from shore. 47 CFR 80.905
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 5 October 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 December 2020 Resolved
Each item of lifesaving eqiupment not in a serviceable condition must be repaired or replaced. Vessel's line on ring buoy is severely deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 October 2021
Sail Rigging › Mast Step › Base
Issued 16 November 2015 Resolved
Upstep mast & make available for inspection by next dry dock date (06 March 2016)
Action required: 705 - Other - as specified
Due 6 March 2016
Resolved 25 February 2016
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 13 November 2015 Resolved
Place original COD onboard vessel.
Due 16 December 2015
Resolved 25 February 2016
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 14 October 2014 Resolved
Vessel did not have written waste management plan onboard. Provide waste management plan specific to this vessel in accordance with 33 CFR 151.57
Action required: 705 - Other - as specified
Due 4 November 2014
Resolved 27 October 2014
Resolution: Satisfactory inspected the written Waste Management Plan aboard the vessel.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 14 October 2014 Resolved
Vessel does not have up to date navigational publications applicable for the vessel's voyage. Provide up to date publications in accordance with 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 4 November 2014
Resolved 27 October 2014
Resolution: Satisfactory Inspected the current edition (printed) of the Coast Pilot and Light List.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 14 October 2014 Resolved
Vessel's pre-engineered fire fighting system does not have an audible alarm installed to indicate discharge. Provide an audible alarm in addition to the visual alarm for the activation of the pre-engineered fixed "fireboy" systems aboard the vessel in accordance with 46 CFR 181.420.
Action required: 705 - Other - as specified
Due 28 October 2014
Resolved 27 October 2014
Resolution: Satisfactory inspected the Fireboy Audible and visual alarms for both engine rooms.
Fire Fighting › Fire Bucket › Quantity
Issued 14 October 2014 Resolved
Crewmember dropped fire bucket overboard during annual inspection/emergency drills. Provide a total of three fire buckets in accordance with 46 CFR 181.610.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 November 2014
Resolved 27 October 2014
Resolution: Satisfactory inspected three fire buckets, properly labeled with lanyards.
Engineering › Steering Gear System › Fastener
Issued 14 October 2014 Resolved
Steering quads have bolts of insufficient length through the rudder posts; they do not engage the nylock nuts. Provide bolts for the steering quad on both sides to fully engage the nuts.
Action required: 705 - Other - as specified
Due 4 November 2014
Resolved 27 October 2014
Resolution: The nuts for the bolts were renewed with a thinner, non-nylock style nut which allowed sufficient amount of thread to pass through the nuts. Lock-tight was also added to the nuts and bolts.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 14 October 2014 Resolved
Owner did not have documentation onboard the vessel proving all crewmembers were enrolled in a random drug testing program. Provide documentation that all employees are enrolled in a random drug testing program in accordance with 46 CFR 16.230.
Action required: 705 - Other - as specified
Due 4 November 2014
Resolved 27 October 2014
Resolution: Satisfactory inspected proper documentation to prove all safety sensitive employees were enrolled in a random drug testing program.
Stability › Intact Righting Energy › General
Issued 7 August 2014 Resolved
Your vessel has been carrying passengers atop the vessel's sunshade while underway. The vessel's stability letter and original deadweight survey did not take this seating configuration into account. Your vessel is prohibited from carrying passengers atop the sunshade until a new stability test is conducted.
Action required: 705 - Other - as specified
Due 7 August 2014
Resolved 7 August 2014
Resolution: Vessel operator stated to [name withheld] that passengers would not be carried atop the sunshade until new stability calculations were conducted.
Engineering › Bilge Water Management System › Piping
Issued 21 October 2008 Resolved
Owner failed to submit approved bilge plans prior to installing system.
Due 7 November 2008
Resolved 31 December 2008
Fire Fighting › Structural - Main Vertical Zones › General
Issued 19 September 2008 Resolved
Plug opening between engineroom and head, to ensure that FE241 does not escape e/r.
Due 5 October 2008
Resolved 5 October 2008
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 19 September 2008 Resolved
Add 2 adult and 1 child lifejacket to meet requirements on COI.
Due 5 October 2008
Resolved 5 October 2008
Navigation › Piloting/Steering › Coast Guard Light List
Issued 19 September 2008 Resolved
Carry light list and coast pilot 4 when operating vessel.
Due 5 October 2008
Resolved 5 October 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 September 2008 Resolved
Replenish missing items from first aid kit.
Due 5 October 2008
Resolved 5 October 2008
Fire Fighting › Ventilation Systems › Ducts
Issued 19 September 2008 Resolved
Label and designate location for vent closure for both port and stb engineroom.
Due 5 October 2008
Resolved 5 October 2008
Engineering › Bilge Water Management System › Piping
Issued 30 June 2008 Resolved
Properly install bulkhead union penetrations on vsl's bilge/fire main system. Hose currently passes thru the WT bulkheads which in not allowed. Label all valves to indicate which space they pump out, post basic operating instructions for vsl's bilge/fire main system.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 13 August 2008
Engineering › Bilge Water Management System › Valve
Issued 30 June 2008 Resolved
Properly install positive shut off valves on all bilge ovbd thru hull connections.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 13 August 2008
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 30 June 2008 Resolved
Properly place draft marks or load marks onto vsl's hull's port/stbd - bow/stern.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 7 July 2008
Fire Fighting › Fire Pumps › Pressure
Issued 30 June 2008 Resolved
Properly install psi gauge on vsl's fire main system.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 13 August 2008
Engineering › Bilge Water Management System › Pump
Issued 30 June 2008 Resolved
Properly install a second bilge pump into vsl's stbd side hull iaw 46 CFR 182.520.j.1.2.3.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 13 August 2008
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 27 September 2007 Resolved
Renew waterproof access covers on the fwd bow void port and stbd.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 November 2007
Resolved 22 October 2007
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 27 September 2007 Resolved
Replace ten missing Adult Type-I lifejackets. Vsl's passenger count limited to the number of CG Approved Type I jackets onboard.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 October 2007
Communications › Radio Communications › VHF Radiotelephone
Issued 27 September 2007 Resolved
Obtain FCC safety certificate for vsl's radio equipment.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 October 2007
Resolved 22 October 2007
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 27 September 2007 Resolved
Have onboard current Nav Rules and Local Charts.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 October 2007
Engineering › Bilge Water Management System › Pump
Issued 27 September 2007 Resolved
Have onboard a backup portable hand bilge pump (10 gph).
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 October 2007
Fire Fighting › Fire Pumps › Arrangement
Issued 27 September 2007 Resolved
Properly repair fire pump mounting bracket pump was found inoperable.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2007
Lifesaving › Hand Flares › Not on Board
Issued 27 September 2007 Resolved
Have onboard six day/night signal flares.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2007
Engineering › Bilge Water Management System › Not Installed
Issued 27 September 2007 Resolved
Install a fixed power bilge system I.A.W. 46 CFR 182.500 at the vessels' next scheduled dry-dock. Submit plans and materials list to the local OCMI for approval prior to installation of the bilge system.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 30 June 2008
Resolution: Owner installed bilge system in vsl without any plan approval process. OCMI is in the process of reviewing the system to make sure it is in compliance with 46 CFR 182.500.
Fire Fighting › Fire Main › Material
Issued 27 September 2007 Resolved
Install proper suction hose, PSI gauge, and shut off valve on vessels fire pump outlet. Properly mount fire hose in a safe location easily and safely assessable to vessels crew and IAW 46 CFR 181 Subpart C.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 30 June 2008
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 12 May 2005 Resolved
provide metal trashcans
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 21 June 2005
Engineering › Bilge Water Management System › Interface Detector
Issued 1 July 2004 Resolved
Install visual & audible indicators for bilge high water alarms at the operating station.
Condition: Improper Installation
Due 15 July 2004
Resolved 16 July 2004
Resolution: Alarms installed satisfactory.
Construction/Loadline › Penetrations › Pipe Flange
Issued 1 July 2004 Resolved
Install hard piping on all vital systems lines over 30"
Condition: Improper Installation
Due 15 July 2004
Resolved 16 July 2004
Resolution: Hard piping installed satisfactory.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 1 July 2004 Resolved
Properly install the pre-engineered fire system IAW manufacturers instructions.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2004
Resolved 2 July 2004
Resolution: Pulls installed.
Engineering › Fuel Oil Service System › Valve
Issued 1 July 2004 Resolved
Properly install fuel shut-offs IAW 46CFR182.455(b)(4)
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2004
Resolved 6 July 2004
Resolution: Shut offs installed.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 1 July 2004 Resolved
Properly lable lifejacket stowage containers.
Condition: Design Flaw
Due 15 July 2004
Resolved 16 July 2004
Resolution: Containers labled satisfactory.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 1 July 2004 Resolved
Provide none-combustible waste receptacles.
Condition: Placed in Improper Service
Due 15 July 2004
Resolved 16 July 2004
Resolution: Non-combustible liners were installed inside the receptacles.
Documentation › Markings/Placards › Warning Signs
Issued 1 July 2004 Resolved
Mount emergency broadcast placard & emergency instructions.
Condition: Improper Installation
Due 15 July 2004
Resolved 16 July 2004
Resolution: Placard mounted satisfactory.
Navigation › Piloting/Steering › Gyro Compass
Issued 1 July 2004 Resolved
Install light on magnetic compass.
Condition: Improper Installation
Due 15 July 2004
Resolved 6 July 2004
Resolution: Light installed.

Casualty record · 1

27 June 2021Routine · role: Involved in a Marine Casualty · activity 7238675
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.