Records from 2010 to 2025. Most recent: inspection, 27 June 2025.
Inspection history · 27
27 June 2025
Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8172712
12 August 2024
Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7981254
7 December 2023
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7833963
27 September 2023
Internal Structural Exam · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7799608
4 April 2023
Liferaft Servicing
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7666176
29 March 2023
Liferaft Servicing
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7663525
12 August 2022
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7531839
5 July 2022
In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7497360
27 May 2022
Administrative Inspection · Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 7460629
26 May 2022
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7904238
15 April 2022
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7431552
5 March 2022
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7404844
26 January 2022
Liferaft Servicing
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7388906
9 December 2021
Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7365479
16 June 2021
Deficiency Check · Examination of Repairs · COI Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7238867
15 April 2021
Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7175827
18 December 2019
Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6876134
13 November 2019
Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6854870
29 October 2019
In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6845030
11 September 2019
In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6809770
4 December 2018
Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6591575
16 November 2018
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6582103
23 February 2018
Liferaft Servicing
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6367256
22 December 2017
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6328132
2 November 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6302085
6 October 2016
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6017526
28 September 2016
Internal Structural Exam · Administrative Inspection · COI Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5998817
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 September 2023
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices must be corrected. 2 different gas meters alarmed for H2S in port engine room; unable to pinpoint exhaust leak. Identify and repair exhaust leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 October 2023
Resolution: Repaired exhaust.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 27 September 2023
Resolved
Each hatch exposed to the weather must be watertight. Identified engine access hatch in port engine room was leaking water into space. Make watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 October 2023
Resolution: Repaired port engine room hatch.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 27 September 2023
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Identified 6 person IBA hydrostatic release was not fitted with a shackle from painter to weak link IAW Hammar manufacturer mounting instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 October 2023
Resolution: Observed satisfactory hydrostatic release.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 12 August 2022
Resolved
Vessel has a puncture of the hull IVO port side aft Apx 18" from transom and Apx 24" above the water line. There is also a sharp dent Apx 24" forward of that Apx 18" above the water line that appears to have a crack: Crop and renew these areas to the satisfaction of the attending CG Marine Inspector, prior to carrying passengers. Submit repair plan to attending CGMI prior to commencing repair.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2022
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 July 2022
Resolved
Pre-engineered fixed fire fighting system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Repair Port engine room power ventilation damper and fan and STBD side engine room power fan.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 July 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 May 2022
Resolved
Vessel lost response of jet drive bucket control and was unable to properly steer or maneuver the vessel. Vessel is required to Trouble shoot and make repairs to the satisfaction of attending CGMI prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 April 2022
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. The starboard engine room submersible electric bilge pump was not properly mounted and was lying its side.
46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 April 2022
Resolved 29 April 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 April 2022
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Starboard engine room electric bilge pump wiring connections were not made within an enclosure and had an excessive amount of excess wiring laying in the bilge. 46 CFR 183.340
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 April 2022
Resolved 29 April 2022
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 15 April 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible;(2) U.S. Coast Pilot or similar publication;(3) Coast Guard Light List;(4) Tide tables. Vessel did not have updated electronic charts or publications onboard. 46 CFR 184.420
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 April 2022
Resolved 29 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 April 2022
Resolved
Flexible hose runs must be visible, easily accessible, protected from mechanical damage, and must not penetrate watertight decks or bulkheads. Port side engine room fuel oil hose is chaffing on the bottom edge of the engine mounting frame. 46 CFR 182.720
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 April 2022
Resolved 29 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 April 2022
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Port side jet drive had small leak at the transom through hull connection. 46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2022
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 5 March 2022
Resolved
Remove wet/saturated insulation in the port and starboard side engine from from the chine up to the shear for reinspection.
Action required: 705 - Other - as specified
Resolved 8 March 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 June 2021
Resolved
Hull was pitted beyond 25% allowable wastage in port engine room near forward bulkhead. crop and renew pit to orignial condition.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2021
Resolved 25 June 2021
Resolution: Wasted bottom plate was cropped and new insert plate was installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 16 June 2021
Resolved
Port railing was cracked forward of access gate. Repair crack.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2021
Resolved 9 July 2021
Resolution: Port railing was repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 June 2021
Resolved
Prove proper operation of main engines to attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2021
Resolved 9 July 2021
Resolution: Completed satisfactory sea trial.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 June 2021
Resolved
Lagging was missing on both MDEs at turbo charger. Ensure all areas of engine that are 150 degrees F or higher are protected.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2021
Resolved 9 July 2021
Resolution: Missing exhaust lagging was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 June 2021
Resolved
The exhaust cooling hose and crankcase breather hose were chaffed on both engines. Renew hoses to original condition.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2021
Resolved 9 July 2021
Resolution: Cooling hoses and breather hoses were renewed on both engines.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 June 2021
Resolved
Ensure bilge pump hoses are properly secured to bilge pump housings.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 July 2021
Resolution: bilge hoses were properly secured to bilge pump.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 June 2021
Resolved
Conduct drills in presence of Marine INspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2021
Resolution: Conducted fire, man overboard, abandon ship drills. All sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 June 2021
Resolved
ensure fixed fire fighting for engine rooms are serviced annually and provide proof of servicing to Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 July 2021
Resolution: Received copy of fixed fire fighting system servicing.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 June 2021
Resolved
Stencil ring life buoy with vessel name.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 July 2021
Resolution: Life buoys were properly stenciled.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 16 June 2021
Resolved
Provide operational portable lights on vessel.
Action required: 10 - Deficiency Rectified
Resolved 16 June 2021
Resolution: Rectified during inspection.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 June 2021
Resolved
Provide a first aid kit on vessel with un-expired medication.
Action required: 10 - Deficiency Rectified
Resolved 16 June 2021
Resolution: Rectified during inspection
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 November 2018
Resolved
Battery terminals must be protected from falling objects; multiple battery terminals and connectors in the 24volt system are open and unprotected.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2019
Resolved 20 November 2018
Resolution: Verified cabels were properly supported every 24"'s.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 22 December 2017
Resolved
Make the main longitudinal wire run bulkhead penetrations watertight in both the port and starboard hulls.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 16 January 2018
Resolution: Verified the reaplication of FIWA fire/water block in the disturbed areas.
Construction/Loadline › Structures › Manhole
Issued 22 December 2017
Resolved
Repair the deck hatch gaskets for the port access to the aft engine room, #3, an #2 void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 16 January 2018
Resolution: Verified all identified hatch gaskets were repaired and or replaced.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 2 November 2017
Resolved
Replace starboard side engine room Pre-engineered Fix Extinguisher bottle bracket. Vessel was granted one time transit to Dry dock for reapir
Action required: 60 - Rectify deficiencies prior to movement
Due 2 November 2017
Resolved 16 January 2018
Resolution: Verified identified bracket was renewed.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 2 November 2017
Resolved
Prove starboard side engine room Pre-engineered Fix Extinguisher bottle is still in serviceable condition using a qualified servicing facility to the satisfaction of the CG inspector. Vessel was granted one time transit to Dry dock for reapir.
Action required: 60 - Rectify deficiencies prior to movement
Due 2 November 2017
Resolved 16 January 2018
Resolution: Verified installation of new pre-engineered system. Operational tests of shutdowns and interlocks sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 November 2017
Resolved
Replace lifeline and water light line on lifebuoy.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 16 January 2018
Resolution: Verified renwal of the lifebuoy's and waterlight's line.
Construction/Loadline › Structures › Trunk
Issued 2 November 2017
Resolved
Repair cracked weld on both aft engine room ventilation duct on both aft corners.
Action required: 705 - Other - as specified
Due 31 December 2017
Resolved 16 January 2018
Resolution: Identified areas were gouged and rewelded. Hose test sat.
Construction/Loadline › Structures › Deck Plating
Issued 2 November 2017
Resolved
Find and repair leak in port side engine room aft overhead.
Action required: 705 - Other - as specified
Due 31 December 2017
Resolved 16 January 2018
Resolution: Identified the vessel's engine room soft patch drain as plugged. Drain cleared and hose test sat.
Operations/Management › Drills/Instruction › Not Conducted
Issued 2 November 2017
Resolved
Conducted drills with CG inspectors.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 16 January 2018
Resolution: Conducted underway drills, all sat.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 28 September 2016
Resolved
Conduct annual testing of the port and stbd engine room pre engineered fixed fire systems and controls.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 October 2016
Resolved 5 October 2016
Resolution: Owner had the two fixed FM 200 fire systems annually inspected and tested -SAT.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 28 September 2016
Resolved
Properly install the gasket onto the port side forward engine room water tight hatch.
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 5 October 2016
Resolution: Owners repair personnel properly installed hatch gasket.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 28 September 2016
Resolved
Reinstall the machinery guards onto the front of the port and stbd main diesel engines.
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 5 October 2016
Resolution: Owners repair personnel reinstalled the machinery guards on the port and stbd engines.
Documentation › Certificates/Documents › FCC SSL
Issued 28 September 2016
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 5 October 2016
Resolution: Owner had current FCC Station License onboard.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 28 September 2016
Resolved
Properly secure the loose passenger bench seat, third bench aft on the stbd side.
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 5 October 2016
Resolution: Owners repair personnel properly secured the bench seat back to the deck.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 September 2016
Resolved
Properly terminate dead end wiring under the port side aft cabinet in the passenger cabin.
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 5 October 2016
Resolution: Owners electricians properly terminated the dead end wiring into a junction box.