MAURY USCG vessel records
← All vessels

ANDES

ANDES is a 2003 tank ship. The Coast Guard has recorded 5 inspections since 2017, most recently in October 2022, along with 2 deficiencies.

Records from 2017 to 2022. Most recent: inspection, 5 October 2022.

Built
2003
Last inspected
5 October 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 October 2022
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2017–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9265366
716051
Flag
MALTA
Maury page id
psix-716051

Documentation record

Tonnage as PSIX records it39085 - Convention (Subpart B), Gross Ton
19936 - Convention (Subpart B), Net Ton
81464 - Displacement, Ton
68439 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

5 October 2022 COC-TVE Renew · PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7570033
5 October 2020 PSC B · MARPOL Annex VI Survey · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7071432
22 March 2019 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6647575
12 March 2018 Ballast Water Examination · ISPS II Exam · COC-TVE Annual · PII Safety Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6369253
12 January 2017 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6066299

Deficiency record · 2

07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 25 March 2019 Resolved
01 The inert gas system referred to in paragraph 5.5.3.1 shall be designed accordance with the Fire Safety System Code Materials used in inert gas systems shall be suitable for their intended purpose. Salt Water line to inert gas scrubber is leaking water. In addition vessel's scrubber appears to have a crack underneath the lower sight-glass.  CODE 60 a c - 74 SOLAS 14 (CONS.) II-2/4.5.5.3.2 FSS CODE 15.2.2.1.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 March 2019
Resolved 31 March 2019
Resolution: Section of inlet piping replaced by crew onboard. Class surveyor went onboard and approved all corrected items.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 25 March 2019 Resolved
02 Personal equipment shall consist of protective clothing of material to protect the skin from heat radiating from the fire and from burns and scalding by steam. 03 out of 06 firefighting outfits have flakes and tears. CODE 17 a c - 74 SOLAS 14 (CONS.) II-2/10.1.1 FSS CODE 3.2.1.1.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 25 March 2019
Resolved 27 March 2019
Resolution: Received delivery note stating receipt of new fire-fighters suits.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.