Records from 2005 to 2022. Most recent: inspection, 5 October 2022.
Inspection history · 32
5 October 2022
COC-TVE Renew · PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7570033
5 October 2020
PSC B · MARPOL Annex VI Survey · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7071432
22 March 2019
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6647575
12 March 2018
Ballast Water Examination · ISPS II Exam · COC-TVE Annual · PII Safety Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6369253
12 January 2017
ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6066299
18 November 2015
Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5761490
29 October 2014
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5009311
14 September 2011
COE-Offshore
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4129119
2 October 2010
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3856635
18 February 2010
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3682111
4 December 2009
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3645011
13 May 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3470967
5 October 2008
ISPS II Exam · COC-TVE Renew · Ballast Water Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3338086
25 June 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3247579
16 January 2008
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3131658
29 October 2007
COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3089462
14 September 2007
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3059878
12 September 2007
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3056269
30 September 2006
Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2790395
23 June 2006
Type not recorded
No type recorded · Maritime Safety & Security Team San Francisco (91105) · Activity 2689604
13 March 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2601567
10 March 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2600262
18 January 2006
Random ISPS/MTSA/PSC
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2571818
28 October 2005
Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2526576
16 September 2005
ISPS III Exam · COC-TVE Annual
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2494334
11 September 2005
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2489692
20 July 2005
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2433120
5 July 2005
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2415312
23 June 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2416811
5 January 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2269106
5 January 2005
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2270030
4 January 2005
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2617594
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 25 March 2019
Resolved
01
The inert gas system referred to in paragraph 5.5.3.1 shall be designed accordance with the Fire Safety System Code Materials used in inert gas systems shall be suitable for their intended purpose. Salt Water line to inert gas scrubber is leaking water. In addition vessel's scrubber appears to have a crack underneath the lower sight-glass. CODE 60 a c - 74 SOLAS 14 (CONS.) II-2/4.5.5.3.2
FSS CODE 15.2.2.1.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 March 2019
Resolved 31 March 2019
Resolution: Section of inlet piping replaced by crew onboard. Class surveyor went onboard and approved all corrected items.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 25 March 2019
Resolved
02
Personal equipment shall consist of protective clothing of material to protect the skin from heat radiating from the fire and from burns and scalding by steam. 03 out of 06 firefighting outfits have flakes and tears. CODE 17 a c - 74 SOLAS 14 (CONS.) II-2/10.1.1 FSS CODE 3.2.1.1.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 25 March 2019
Resolved 27 March 2019
Resolution: Received delivery note stating receipt of new fire-fighters suits.
Electrical › Electric Generation Source (emergency) › Generator
Issued 29 October 2014
Resolved
74 SOLAS 2004 cons Ch 1 Reg 11, During the RCOC the PSCO witnessed fluctuations (Hunting) between 60 - 30 Hz, with the Emergency Generator when placed under load. (while operating the Emergency fire pump and steering. 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 November 2014
Resolution: Vessel submitted class report attesting to the proper functionality of the Emergency Generator.
Engineering › Steam Boiler (auxiliary/waste heat) › Fuel Oil Burner
Issued 29 October 2014
Resolved
74 SOLAS 09 cons Ch II, Reg 4; PSCO witnessed fuel leak on the top of Aux boiler which suppies flue gas to the Inter Gas System, there was a steady drip (not stream) of fuel leak off of the pipe. 10c
Due 29 October 2014
Resolved 29 October 2014
Resolution: This was corrected on the spot.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 29 October 2014
Resolved
74 SOLAS 04 Ch I Reg 11, during the exam PSCO witnessed several grates at the port and starboard transfer maniforlds to be completely wasted through with large holes.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 November 2014
Resolution: Vessel submitted class report attesting to the replacement of all worn and wasted gratings in affected areas.
Deck/Cargo › Inert Gas System › IGS Blower
Issued 5 October 2008
Resolved
2045 - Cargo Operation - Inert Gas System high temperature shutdown is not working in accordance to the system operating procedures. Repairs and testing to be performed and verified by Class Surveyor, prior to conducting cargo operations in U.S. port. Class report to be provided to Coast Guard. SOLAS II-2 / 4.5.5 17 (a,b,c)
Action required: 705 - Other - as specified
Due 5 October 2008
Resolved 7 October 2008
Resolution: Item cleared based on receipt of Lloyds Register Class report #LAN0820223, dated 07 OCT2008. Class Surveyor witnessed Satisfactory operational test of system after circuit board containing control relay was replaced by service technician.
Lifesaving › Immersion Suits › Serviceable
Issued 30 October 2007
Resolved
Two immersion suits had broken zippers and where not ready for service. Several of the zippers on the immersion suit bags were frozen and therefore the crew was unable to don immersion suits.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 October 2007
Resolution: Master provided an order reciept for two new immersion suits to be picked up in Los Angeles, which is the next port of call. The crew was also instructed on proper maintenance of immersion suit bags and the frozen zippers on the bags were fixed.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 30 October 2007
Resolved
Cargo transfer procedures do not contain all required items including cargo specific information, engineers duties, and vapor control requirements.
Action required: 705 - Other - as specified
Resolved 30 October 2007
Resolution: An electronic template of cargo transfer procedures in accordance with 33 CFR 155.750 was given to the captain.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 30 October 2007
Resolved
Doors leading into accommodation spaces in upper decks from outside were locked from the inside. Master key not available creating a conflict between safety and security. Keyhole covers on door exteriors were frozen closed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 October 2007
Resolution: Crewmembers loosened the keyhole covers and provided a key to unlock the doors.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 30 October 2007
Resolved
Company guidelines on maintenance of immersion suits does not exist. Crew does not know when to inspect suits, which led to deterioration of zippers on bags and 15 immersion suits. Class/Flag is to review the guidelines for maintenance of immersion suits and implement any changes into their safety management system.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 January 2008
Resolution: Instructions for monthly inspection and periodic test of immersion suits as per manufacture instructions are now included in the Maintenance Plan for Life saving appliances.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 30 October 2007
Resolved
Garbage Management Plan is not specific to the ship. The plan does not address incineration and hazardous/medical waste collection specifically leading to confusion in crew. Vessel is to provide an amended plan to the satisfaction of class/flag.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 January 2008
Resolution: Incineration process and collection instructions for Hazardous and Medical Waste is now included in the Garbage Management Plan.
Construction/Loadline › Hull › Hull Plating
Issued 5 January 2005
Resolved
As a result of an allision, the vessel the side shell plating in the #5 Port wing ballast tank was found set in and torn approx. 1 meter in way of the 2nd web frame from the aft transverse watertight bulkhead and between the 7th and 8th side shell longitudinals from the deck head. The internals were also found distorted. A requirement was issued to provide a repair proposal prior to any cargo ops.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 5 January 2005
Resolved 5 January 2005
Resolution: A repair proposal from LR was received and accepted. The vessel was cleared to conduct cargo operations.
Construction/Loadline › Hull › Hull Plating
Issued 5 January 2005
Resolved
As a result of an allision, the vessel the side shell plating in the #5 Port wing ballast tank was found set in and torn approx. 1 meter in way of the 2nd web frame from the aft transverse watertight bulkhead and between the 7th and 8th side shell longitudinals from the deck head. The internals were also found distorted. A requirement was issued to make permanent repairs to satisfaction of class.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 5 January 2005
Resolved 8 January 2005
Resolution: Received, reviewed and accepted class report from [name withheld] stating that permanent repairs were completed, tested and found satisfactory. Cleared the vessel to sail.