Records from 2004 to 2026. Most recent: inspection, 5 June 2026.
Documentation record
Registered dimensions (L × B × D)460.8 ft × 78.0 ft × 36.5 ft
Registered tonnagegross 8,722 / net 8,722
ITC dimensions (L × B × D)460.8 ft × 78.0 ft × 36.5 ft
ITC tonnagegross 10,256 / net 6,678
BuilderMANITOWOC MARINE GROUP LLC · STURGEON BAY, WI, UNITED STATES · built 2004
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPHILADELPHIA, PA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 18 November 2025 · expires 31 December 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10256 - Convention (Subpart B), Gross Ton
21593 - Dead Weight, Gross Ton
8722 - Regulatory (Subpart C or D), Gross Ton
6678 - Convention (Subpart B), Net Ton
8722 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 39
5 June 2026
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8393060
9 March 2026
Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8322802
15 March 2025
In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8094286
25 February 2025
Administrative Inspection · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8084564
10 December 2024
Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8045576
17 September 2024
Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7990212
13 October 2023
Deficiency Check · Periodic Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7806374
18 January 2023
Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7620039
20 October 2022
Annual Inspection · MTSA Verification · Administrative Inspection · MARPOL Annex I Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7581228
28 October 2021
Annual Inspection · MTSA Verification · MARPOL Annex I Examination · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7337910
29 July 2020
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7018957
15 January 2020
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6889193
4 January 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6605812
25 January 2018
MARPOL Annex I Examination · MTSA Verification · Periodic Inspection · Internal Structural Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6342005
27 March 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6133816
22 February 2017
MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6089128
20 January 2017
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6071875
16 February 2016
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5816243
28 January 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5805569
19 January 2016
Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5803113
4 December 2014
COI Inspection · Cargo Tank Internal · Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5034300
2 December 2013
MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4760380
9 July 2013
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4647864
20 September 2012
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4445967
18 June 2012
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4350955
27 April 2012
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4299350
13 December 2011
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4203121
10 December 2009
Administrative Inspection · Internal Structural Exam · DAPI Audit · Drydock Exam · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3654137
25 February 2009
MARPOL Annex I Examination · Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3423556
10 October 2008
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3342332
6 March 2008
Administrative Inspection · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3151857
12 December 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3114160
3 December 2007
Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3176616
16 November 2007
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3100863
12 January 2007
Administrative Inspection · MTSA Verification · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2854664
25 January 2006
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2571677
26 October 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2228595
24 September 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2204116
15 September 2004
MTSA Verification · Hull Examination · Initial Certification · Internal Structural Exam · Administrative Inspection · Cargo Tank Internal · Construction Oversight
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2196767
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 March 2025
Resolved
Items of equipment, which are in use on vessels, previously approved by the Commandant but not complying with the latest specification requirements may be continued in use so long as they are maintained in good and serviceable condition to the satisfaction of the Officer in Charge. Turbo on #1 generator caught fire while in use. Generator is not to be used until diagnostics and repairs are provided by technician. Repair to the satisfaction of the marine inspector.
46 CFR 50.05-1(d)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 March 2025
Resolved 20 March 2025
Resolution: Tech attended the vessel and provided report. Reports in def docs.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 October 2023
Resolved
The lifejackets must be readily accessible. Life jackets were stored in the back of an area used for storage, there is obstacles in the way of the life jackets. Correct to the satisfaction of the attending Marine Inspector. 46CFR 199.70 (b)(2)(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2023
Resolved 24 October 2023
Resolution: Port Captain provided objective evidence that the Life Saving Equipment complies with regulation to the satisfaction of CG Marine Inspector from Sector Corpus Christi.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 13 October 2023
Resolved
Any tank vessel which is equipped with an internal combustion engine driven cargo pump on the weather deck shall be provided with a minimum of one remote manual shutdown station, conspicuously marked, and located at the midpoint of such vessel, or 100 feet from the engine, whichever is the more practical. The remote quick acting manual shutdown shall be installed on the engine so as to provide a quick and effective means of stopping the engine (such as by cutting off the intake air). Number one Cargo pump prime mover did not shut down when the emergency stop was pulled. Repaired during inspection. 46 CFR 32.50-35 (a)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 13 October 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 October 2023
Resolved
All tank vessels are subject to the regulations contained in subchapter J (Electrical Engineering) of this chapter except as such regulations are modified by the regulations in this subchapter for tank vessels. Two cable transits in the generator room and one cable transit in the port side cargo engine room are not installed properly and are allowing vapor to pass by the cables. Repair to the satisfaction of the attending Marine Inspector. 46 CGR 31.35-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2023
Resolved 9 November 2023
Resolution: Port Captain provided objective evidence that the cable transit installations comply with regulation to the satisfaction of CG Marine Inspector from Sector Corpus Christi.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 13 October 2023
Resolved
Each immersion suit or anti-exposure suit must be marked in such a way as to identify the person or vessel to which it belongs. Immersion suits were not marked with the name of the barge. Correct to the satisfaction of the attending Marine Inspector. 46 CFR 199.70 (c)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2023
Resolved 24 October 2023
Resolution: Port Captain provided objective evidence that the Life Saving Equipment complies with regulation to the satisfaction of CG Marine Inspector from Sector Corpus Christi.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 28 October 2021
Resolved
Cargo pump through bulkhead shaft seals failed to provide a gas tight atmosphere.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 November 2021
Resolved 4 November 2021
Resolution: New shaft seals were installed around all cargo pump shafts.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 16 February 2016
Resolved
Must provide proper calibration tests for all 28 gauges on cargo piping and VCS piping prior to transfer of cargo.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2016
Resolution: Provided proof of gauge calibration check, included in the documents section of this activity. The company must provide proof of calibration checks of pressure gauges on the VCS piping before operating it.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 22 January 2016
Resolved
During loading operation on 19JAN2016, vessel discovered approximately 12 gallons of product (VGO) in main vapor line. Vessel has locked out / tagged out vapor line. Vessel may not use vapor line until the piping and associated P/V valve has been cleaned to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 22 February 2016
Resolved 20 January 2017
Resolution: Cleaned to the satisfaction of the attending Marine Inspector.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 19 January 2016
Resolved
While conducting loading operations in Texas City, the subject vsl spilled product out of the P/V valve and onto deck / into the water. Vsl must provide explanation for how liquid collected in vapor line/eventually spilled, and assurances of how this will not occur during future loading ops, to the satisfaction of local OCMI prior to recommencing loading operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 January 2016
Resolved 20 January 2016
Resolution: Vessel drained approximately 12 gallons of liquid product from vapor line and has locked out / tagged out vapor line.
Engineering › Fuel Oil Service System › Hose
Issued 13 December 2011
Resolved
Fuel hoses on the thermal fluid heater do not comply with SAE J-1942 standards.
Action required: 705 - Other - as specified
Due 13 January 2012
Resolved 14 December 2011
Resolution: Hoses replaced
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 25 February 2009
Resolved
Prove proper operation of #3 Bergan tank level display unit.
Action required: 705 - Other - as specified
Due 27 March 2009
Resolved 2 March 2009
Construction/Loadline › Markings › Load Line Mark
Issued 25 February 2005
Resolved
Gain a modified/second Load Line Certificate for carriage of crude oil and install permanent LL marks since vessel's DWT exceeds 20,000 DWT with the current Load Line. Vessel restricted from the carriage of crude oil until proper LL assigned.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 6 March 2008
Resolution: Permanent LL are properly placed on the vsl