Records from 1997 to 2026. Most recent: inspection, 18 March 2026.
Inspection history · 28
18 March 2026
Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8327999
11 March 2026
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8324803
11 December 2025
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8282375
24 July 2025
Administrative Inspection · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8194576
24 July 2025
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8272405
12 January 2024
Internal Structural Exam · MTSA/ISPS Verification · Deficiency Check · Drydock Exam · COI Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7834142
6 March 2023
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7646443
24 October 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7583433
23 October 2022
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7623866
25 July 2022
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7515968
8 February 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7392847
8 January 2021
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7121765
2 November 2020
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7088548
29 September 2020
In-Service Inspection · Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7068115
20 April 2020
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6942112
18 June 2019
Initial Certification · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6718016
12 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6538966
20 June 2018
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6450396
11 April 2018
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6392796
6 December 2012
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4513946
1 December 2012
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4513932
11 May 2004
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2065225
11 May 2004
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2065229
8 June 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 675469
27 February 2000
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 169085
1 January 2000
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1686882
31 December 1999
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 133544
20 November 1997
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 51956
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2026
Resolved
Vessel reported a spun shaft bearing. Correct issue and notify local OCMI once complete.
Action required: 705 - Other - as specified
Resolved 13 April 2026
Resolution: MI attended vessel to conduct sea trial. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 March 2026
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons on-board under normal and emergency conditions. MI received report of vessel's port shaft casualty caused by shaft sleeve migrating four inches forward allowing water ingress. Vessel is authorized one time transit from Newport, CA to San Diego, CA to affect repairs. Vessel is required to follow transit plan provided by Port Captain to USCG.
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Due 11 April 2026
Resolved 30 April 2026
Resolution: Vessel proceeded to SSD and repairs were completed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 December 2025
Resolved
Thermocouple on port MDE was found damaged due to proximity to turbo exhaust leak, Prevent further damage by installing lagging and removing from heat until replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 January 2026
Resolution: Pics rcvd
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 December 2025
Resolved
Port main engine was observed with a significant exhaust leak. Troubleshoot and repair exhaust leak and demonstrate repairs in sea trials. 46CFR143.205
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2025
Resolution: Received report from MDE technician
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 December 2025
Resolved
Port shaft seal was observed with a significant shaft seal leak. Repack and demonstrate operation during sea trials . 46CFR143.205
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 December 2025
Resolution: Witnessed satisfactory operation
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 December 2025
Resolved
Submit one line electrical diagram demonstrating the power sources are capable of carrying the electrical load of the towing vessel under normal operating conditions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2026
Resolved 5 March 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 December 2025
Resolved
Port bilge pick up was found touching the deck and unable to be tested. Lift bilge pick up, evaluate material condition under and test to ensure operational status, submit condition to OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 December 2025
Resolution: Witnessed satisfactory operation
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 December 2025
Resolved
Forepeak decking was observed as compromised plywood. Replace deck plates for crew safety. 46CFR143.205
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 December 2025
Resolution: Witnessed satisfactory operation
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 December 2025
Resolved
Multiple areas of exposed wires were found throughout engine room. Permanent dead end all exposed wires. 46CFR143.400
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 January 2026
Resolution: Operator sent in pictures of deficiency cleared, will need to follow up on every inspection
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 December 2025
Resolved
Electrical systems must function properly and minimize fire shocks and hazards, connections shall be suitably installed, equipment and cables must be protected. Wiring in engine room was observed with open splices and loose unsupported conductors near both mains. Throttle control was unsupported. Electrical connections not secured against vibration. Clean up cables near engines Support throttle control connections with stanchions to remove from walk way. Install blanks in switchboard.46CFR143.400
Throttle control connections are extended until drydock due to the need to consult with electrician and install stanchions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2025
Resolved 23 January 2026
Resolution: Pictures and email attesting to the repairs sent in
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 December 2025
Resolved
Surge protectors were found installed to power battery chargers. Remove surge protector(s).46CFR143.400
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 December 2025
Resolution: Witnessed satisfactory operation
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 11 December 2025
Resolved
All crewmembers must be provided with health and safety information and training that includes:. No records of training on board.46CFR 140.515(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 December 2025
Resolution: Witnessed satisfactory operation
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 11 December 2025
Resolved
No later than July 22, 2019, the owner or managing operator must implement a health and safety plan. The health and safety plan must document compliance with this part and include recordkeeping procedures. Complete health and safety plan not on board. 46cfr140.500(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 December 2025
Resolution: Witnessed satisfactory operation
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 11 December 2025
Resolved
Portable fire extinguishers must be tested in accordance
with the inspection, maintenance procedures and hydrostat
pressure tests required by Chapters 7 and 8 of NFPA 10.46CFR142.240(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 December 2025
Resolution: Witnessed satisfactory operation
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 11 December 2025
Resolved
Line throwing appliance. Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040. Vessel had one line throwing appliance with no additional charges. 4 line throwing appliance or one with 3 spare charges required, 46CFR§141.385
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 January 2026
Resolution: Pics rcvd
11 - Life Saving Appliances › N/A - No Subsystem › Anti-exposure suits
Issued 11 December 2025
Resolved
In addition to the immersion suits required under paragraph (a)(1) of this section, each watch station, work station, and industrial work site must have enough immersion suits to equal the number of persons normally on watch. No immersion suit on the bridge 46CFR141.350(a)(2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2025
Resolution: Witnessed satisfactory operation
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 December 2025
Resolved
Each towing vessel must be equipped with navigation lights. Stern light did not appear to be operating. 46CFR140.720. Repair prior to overnight operations
Action required: 705 - Other - as specified
Resolved 17 December 2025
Resolution: Witnessed satisfactory operation
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 11 December 2025
Resolved
The VSO must ensure that at least one security drill is conducted at least every 3 months. No drills logged since 2024. 33CFR104.230
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 January 2026
Resolution: rCVD PICS
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 11 December 2025
Resolved
Union was found damaged leading to excessive water leak in the engine room during inspection.
Action required: 10 - Deficiency Rectified
Resolved 17 December 2025
Resolution: Union replaced and video sent of repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 July 2025
Resolved
Vessel reported the shaft shearing. Vessel is prohibited from movement without MI approval until repairs are complete and sea trials are witnessed. 46CFR
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 October 2025
Resolution: MI attended vessel to conduct sea trial. All SAT
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 July 2025
Resolved
Two pin holes were found on the starboard side bow, underneath the rub rail. Vessel is authorized to complete a temporary fix within 30 days, but was instructed that they will have to crop and renew at the next drydock which will take place in 14 months.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2025
Resolved 2 February 2026
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 March 2023
Resolved
A towing vessel subject to this subchapter and choosing the Coast Guard inspection option, or required to have the Coast Guard inspection option, must undergo an annual inspection within 3 months before or after the COI anniversary date. Vessel failed to receive an annual inspection. Complete annual inspection with CG.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 June 2023
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 6 March 2023
Resolved
A towing vessel, other than an excepted vessel, must have a backup or a second power source that has adequate capacity to supply power to essential alarms, lighting, radios, navigation equipment, and any other essential system identified by the cognizant OCMI or a TPO. Vessel backup generator is inoperable. Provide backup power source with adequate capacity.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 March 2023
Resolved
Main engines and generators found to be missing protective covers for belts. Install covers.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2023
Resolved 18 July 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 March 2023
Resolved
Port side fuel tank sight glass found to be missing guards. Install guards.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 June 2023
Resolution: Installed guards
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 6 March 2023
Resolved
New generator installation requires Load analysis. Provide load analysis of generator.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 June 2023
Resolution: Provided load analysis. SAT
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 6 March 2023
Resolved
Vessel's IBA found to be removed for service. Install IBA.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 October 2022
Resolved
The drydock examination must be conducted while the vessel is hauled out of the water or placed in a drydock or slipway. The Coast Guard inspector or surveyor conducting this examination must: Examine the propellers for cracks and damage. New propeller must be installed to the satisfaction of the attending marine inspector prior to conducting towing operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 November 2022
Resolution: New propeller installed and satisfactory sea trial conducted.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 July 2022
Resolved
(2) Two fire detection sensors in the engine room were unable to be tested without rendering them inoperable. Replace both fire detection sensors in the engine room.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 25 July 2022
Resolution: USCG received satisfactory evidence of the operation of the two fire detection sensors in the engine room.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 July 2022
Resolved
Emergency lighting must be provided for all internal crew working and living areas and must provide sufficient illumination to facilitate egress.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 July 2022
Resolution: Received evedince of approved emergency lighting being installed.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 25 July 2022
Resolved
Brake for starboard forward winch was reported as inoperable. Repair winch prior to cargo operations.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 July 2022
Resolved 27 July 2022
Resolution: Provided evedince of winch brake being operational.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 July 2022
Resolved
FWD watertight door seal found to be worn and not providing a full seal. Replace seal
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 July 2022
Resolution: Provided evedince that watertight door seal was replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 February 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 7 November 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 February 2022
Resolved
EACH LIFEBUOY ON A TOWING VESSEL MUST BE MARKED WITH THE NAME OF VESSEL IN BLOCK CAPITAL LETTERS. RE MARK LIFEBUOYS.
Action required: 705 - Other - as specified
Resolved 7 November 2022
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 8 February 2022
Resolved
EACH TOWING VESSEL MUST BE EQUIPPED TO DETECT SMOKE IN BERTHING AREAS AND KEPT OPERATIONAL AT ALL TIMES WHILE CREW IS ONBOARD. RE-INSTALL TOPSIDE PORT BERTHING SMOKE DETECTOR.
Action required: 705 - Other - as specified
Resolved 7 November 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 February 2022
Resolved
ELECTRICAL SYSTEMS MUST MINIMIZE SHOCK HAZARDS TO PERSONNEL. PROPERLY INSTALL TOPSIDE STARBOARD BERTHING LIGHT FIXTURE.
Action required: 705 - Other - as specified
Resolved 7 November 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 November 2020
Resolved
COMPANIES WITH 1 VESSEL IN FLEET MUST HAVE A COI ONBOARD PRIOR TO JULY 20, 2020. VESSEL SHOWS C-RAY INC AS MANAGING OWNER ON CERTIFICATE OF DOCUMENTATION WHICH HAS ONLY 1 VESSEL ASSIGNED.
VESSEL MUST HAVE A VALID COI ONBOARD NLT 04 DEC 2020.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2020
Resolved 15 December 2020
Resolution: COI ISSUED
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 November 2020
Resolved
COMPANIES WITH 1 VESSEL IN FLEET MUST HAVE A COI ONBOARD PRIOR TO JULY 20, 2020. VESSEL SHOWS C-RAY INC AS MANAGING OWNER ON CERTIFICATE OF DOCUMENTATION WHICH HAS ONLY 1 VESSEL ASSIGNED.
VESSEL MUST HAVE A VALID COI ONBOARD NLT 04 DEC 2020.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2020
Resolved 3 December 2020
Resolution: COI ISSUED
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 September 2020
Resolved
REPLACE BOTH AIR RECEIVERS PRESSURE RELIEVING VALVES WITH VALVES RATED NO MORE THAN 10% OF THE TANK MAWP OF 250 PSI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 October 2020
Resolution: Replaced
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 29 September 2020
Resolved
ENSURE STBD HEAT DETECTOR IN ENGINE ROOM IS REPLACED AND FIRE DETECTION SYSTEM IS RESET TO DETECT EXCESSIVE HEAT AS REQUIRED.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 October 2020
Resolution: System operational
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 29 September 2020
Resolved
ENSURE ALL ENGINE ROOM BULKHEAD PENETRATIONS AND CABLE RUNS ARE SEALED TO PREVENT PASSAGE OF SMOKE AND FLAMES FROM ACCOMMODATION SPACES.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 October 2020
Resolution: Sealed
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 29 September 2020
Resolved
REPAIR ALL E LIGHTS TO ENSURE SUFFICIENT LIGHTING UNDER EMERGENCY CONDITIONS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 October 2020
Resolution: e lights operational
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 29 September 2020
Resolved
PRIOR TO ANY TOWING RELATED OPERATIONS, COMPLETE THE REQUIRED TOWING GEAR INSPECTION RECORD.
Action required: 705 - Other - as specified
Resolved 27 October 2020
Resolution: completed
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 29 September 2020
Resolved
ENSURE PROPER SIGNAGE IS POSTED TO IDENTIFY VESSELS GENERAL ALARM.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 October 2020
Resolution: corrected
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 September 2020
Resolved
VERIFY ALL ELECTRICAL LOADS FROM MAIN DISTRUBUTION PANELS. SEVERAL SPARES ARE BEING UTILIZED.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 October 2020
Resolution: corrected
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 29 September 2020
Resolved
REPLACE OR REPAIR SPOT (SEARCH) LIGHT.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 October 2020
Resolution: corrected
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 September 2020
Resolved
REPLACE MISSING ELECTRICAL OUTLET COVER ON BRIDGE.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 October 2020
Resolution: corrected
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 September 2020
Resolved
In transom, determine condition of possible areas of deck wastage (02 port side/01 just stbd of centerline) and 01 possible crack on port turn of sheer strake.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 October 2020
Resolution: corrected
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 July 2019
Resolved
All owners of managing operators of more than one existing towing vessel must have a valid Certificate of Inspection (COI) issued and on board for 25% of the towing vessels by July 22, 2019. The existing towing vessel KILLEEN does not have a valid COI issued and on board.
Action required: 60 - Rectify deficiencies prior to movement
Due 23 July 2019
Resolved 13 August 2020
Resolution: Company fleet now at 50%
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 12 September 2018
Resolved
IMO: Vsl is broadcasting invalid IMO #
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 December 2018
Resolution: Verified in VIVS
Engineering › Fuel Oil Service System › Tank
Issued 20 June 2018
Resolved
Port fuel tank crack located inboard center. Starboard fuel tank crack located starboard side.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 August 2018
Resolution: Both tanks were repair by inserting 1/4inch steel plates. Witnessed leak test @ 2 psi and held for approx 20 minutes.