Records from 1991 to 2025. Most recent: inspection, 9 September 2025.
Documentation record
Registered dimensions (L × B × D)106.9 ft × 35.1 ft × 16.0 ft
Registered tonnagegross 139 / net 94
ITC dimensions (L × B × D)106.9 ft × 35.1 ft × 16.0 ft
ITC tonnagegross 358 / net 107
BuilderHOUMA WELDERS INC · HOUMA, LA, UNITED STATES · built 1975
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORTLAND, OR
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 June 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it358 - Convention (Subpart B), Gross Ton
139 - Regulatory (Subpart C or D), Gross Ton
107 - Convention (Subpart B), Net Ton
94 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
9 September 2025
COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8225682
7 January 2023
Bulk Liquid Transfer Monitor
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7618138
10 September 2021
Special Consideration
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7311715
23 June 2021
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7288629
11 September 2020
Initial Certification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7020577
24 September 2015
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5730704
23 September 2015
Marine Casualty Follow Up
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5727701
28 May 2014
MTSA Verification · Industry Initiated Exam · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4872727
11 May 2011
Industry Initiated Exam · MTSA Verification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4009837
7 September 2006
MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2771748
26 May 2005
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2368742
11 January 2005
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2272660
11 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1963193
19 August 2002
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1682816
27 February 2000
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 169085
27 February 2000
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 229228
2 October 1998
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 222786
5 May 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 172992
5 May 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 57731
2 February 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 45101
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 September 2025
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. Check valve for bilge system was inoperable during suction test.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2025
Resolved 9 September 2025
Resolution: Found worn check valve. removed, replaced valve and retesed. Test sat.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 September 2025
Resolved
lexible connections and discharge hoses on all fixed extinguishing systems must be inspected and tested in accordance with 46CFR147.65 of this chapter. One of the fixed fire system discharge line was pinched.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2025
Resolved 15 September 2025
Resolution: Lin Tec replaced line.