Documentation record
Registered dimensions (L × B × D)56.2 ft × 19.9 ft × 8.2 ft
Registered tonnagegross 63 / net 43
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPORTLAND OR · built 1956
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 25 November 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it63 - Regulatory (Subpart C or D), Gross Ton
43 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 33
2 March 2026
COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8314628
24 March 2025
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8100939
27 February 2025
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8085855
29 May 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7922467
21 March 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7883181
13 February 2024
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7865199
17 August 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7770904
17 August 2023
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7773675
16 March 2023
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7650223
30 January 2023
Hull Examination · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7629270
7 April 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7427201
23 February 2021
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7145022
10 April 2020
Initial Certification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6937823
14 July 2014
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4921760
16 April 2014
Industry Initiated Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4837258
3 May 2013
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4586275
18 April 2012
MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4289708
21 March 2011
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3976136
28 February 2011
Deficiency Check · Industry Initiated Exam · MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3943419
29 April 2010
Type not recorded
No type recorded · USCGC TERN (WPB 87343) · USCG Southwest District (CGD-SW) · Activity 3736674
23 March 2010
DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3701478
15 April 2009
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3458335
25 March 2006
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2650604
14 March 2006
MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2602614
9 February 2006
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2582597
6 May 2005
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2351346
27 April 2005
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2344407
23 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978788
16 November 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1707031
23 January 2002
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1721919
17 February 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 232075
5 May 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 172992
26 October 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 176894
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 March 2026
Resolved
Every portable fire extinguisher must be supplied with a suitable bracket which will hold the extinguisher securely in its stowage location on vessels or boats, and which is arranged to provide quick and positive release of the extinguisher for immediate use. The mounting bracket for the portable fire extinguisher located outside the paint locker is broken. Rectify to the satisfaction of MI.
46 CFR 162.028-3
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2026
Resolved 16 March 2026
Resolution: Recieved proof of bracket replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 March 2026
Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. The protective bag containing the buoyant lifeline for the port side life buoy is completely deteriorated and falling apart. Rectify to the satisfaction of MI.
46 CFR 141.230
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2026
Resolved 16 March 2026
Resolution: Recieved proof of buoy line bag replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 March 2026
Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. The retro-reflective tape on the life buoy located FWD of the main deck is peeling and deteriorated. Rectify to the satisfaction of MI.
46 CFR 141.230
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2026
Resolved 16 March 2026
Resolution: Recieved proof of retro tape replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 March 2026
Resolved
Life jackets must have the following attachments and fittings: Each life jacket must have a life jacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the life jacket. Crew self reported that they identified that the lights attached life jackets were expired. Rectify to the satisfaction of MI.
46 CFR 141.340(g)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 March 2026
Resolved 16 March 2026
Resolution: Recieved proof of lifejacket lights replaced.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 2 March 2026
Resolved
An EAP training program must be conducted for the employer's crew members and supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. Rectify to the satisfaction of MI.
46 CFR 16.401(b)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2026
Resolved 16 March 2026
Resolution: Recieved Proof of EAP supervisor training.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 May 2024
Resolved
There must be an installed or portable bilge pump for emergency dewatering. Any portable pump must have sufficient hose length and pumping capability. Marine Inspectors were unable to test the capabilities of the vessel's bilge system due to uncleanness of the bilge. Clean the bilge and conduct satisfactory bilge test with the satisfaction of the Marine Inspector.
46CFR143.275
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2024
Resolution: Witnessed satisfactory operation.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 29 May 2024
Resolved
AIS carriage —(1) AIS Class A device. The following vessels must have on board a properly installed, operational Coast Guard type-approved AIS Class A device: (ii) A towing vessel of 26 feet or more in length and more than 600 horsepower, engaged in commercial service. Vessel's AIS was found inoperable. Repair AIS to the satisfaction of the Marine Inspector.
33CFR164.46(b)(1)(ii)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2024
Resolved 30 May 2024
Resolution: Witnessed satisfactory operation.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 13 February 2024
Resolved
The master must ensure that all hatches doors and other openings designed to be watertight or weather-tight function properly. MI observed numerous inoperable and frozen dogging devices on portside galley watertight door, engine room door and on port and starboard window dead covers. Vessels port side window on main deck was cracked. 46 CFR 140.610(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2024
Resolution: All watertight doors and windows functioned properly.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 February 2024
Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards and to ensure the following: All bilges and void spaces are kept free from accumulation of combustible and flammable materials and liquids insofar as practicable. MI observed excessive dirty oil mixture in the engine room bilge, and lube oil tank leaking from a potential weep spot and plug at the bottom of the storage tank. 46 CFR 142.220(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 March 2024
Resolution: Lube oil tank was repaired and O ring replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 August 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel reported a loss of propulsion in SF Bay. Upon arrival, vessel shall remain at berth to identify causal factors and conduct repairs. Additionally, vessel shall conduct sea trials to the satisfaction of the attending marine inspector prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 21 August 2023
Resolution: Vessel responded with a statement stating that after refueling the tug, bleeding all fuel supply lines, and priming the filters, engines ran with no issues for 20 mins. This statement is to the satisfaction of the marine inspector.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 16 March 2023
Resolved
No person may operate any vessel equipped with installed toilet facilities unless it is equipped with an operable Type II or III device that has a label on it under 159.16 or that is certified under 159.12 or 159.12a. Manufacturer required routine maintenance of Type II MSD not being conducted.
33 CFR 159.7(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2023
Resolved 14 April 2023
Resolution: Received maintenance plan from operator.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 4 March 2021
Resolved
All bilges are to be kept free from accumulation of combustible and flammable materials and liquids. Discovered significant volume of accumulated oily water in the engine room bilges. 46 CFR 142.220(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 March 2021
Resolved 18 March 2021
Resolution: Received documentation showing clean bilges in the engine room compartment.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 March 2021
Resolved
A fixed fire pump must be capable of delivering water at a pressure of 50 psi. Fixed fire pump pressure gauge inoperable with small leak identified. Could not verify pressure. 46 CFR 142.325(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2021
Resolved 6 April 2021
Resolution: Received electronic documentation from vessel rep displaying satisfactory operational test of fire pump (working gauge and no leaks).
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 4 March 2021
Resolved
Any piping that penetrates the hull below the waterline must be fitted with a valve that is clearly marked with labeling or color-coding that enables the crew to identify its function. Fire pump suction valve missing label and not color-coded. 46 CFR 143.250(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2021
Resolved 29 March 2021
Resolution: Received documentation from vessel rep with properly labeled fire pump suction valve.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 4 March 2021
Resolved
The total relieving capacity of the relief valve must prevent pressure from exceeding the MAWP, relief valve must be tested, and all pressure vessels must have the MAWP indicated. For both pressure vessels in the engine compartment the MAWP was not listed, the relief valve setting was greater than maximum indication on pressure gauge, and valve testing could not be verified. 46 CFR 143.300(a)-(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2021
Resolved 29 March 2021
Resolution: Received documentation of new pressure relief valves installed on both pressure vessels and MAWP stenciled on the tank to match gauge level.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 March 2021
Resolved
Electrical panels with more than 1 source of power are required to be fitted with a sign warning of the condition and where to secure all sources. Required warning sign missing from electrical panel in engine compartment. 46 CFR 143.250(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2021
Resolved 29 March 2021
Resolution: Received documentation depicting required warning signs.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 4 March 2021
Resolved
The operator must secure each Type II MSD in a manner that prevents sewage discharge. Type II MSD missing padlock to secure overboard discharge valve from accidental discharge. 33 CFR 159.7(b)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 April 2021
Resolved 6 April 2021
Resolution: Received electronic documentation from vessel rep displaying installed ball valve with locking device for MSD device.
Documentation › Logs/Records › Drug Test Records
Issued 23 March 2010
Resolved
Company does not have a Substance Abuse Professional (SAP) name and contact information, as required by 49 CFR 40.287.
Due 23 April 2010
Resolved 23 March 2010