Records from 2006 to 2026. Most recent: inspection, 7 May 2026.
Inspection history · 40
7 May 2026
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8372067
29 April 2025
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8120313
15 May 2024
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7912100
1 April 2024
Deficiency Check · Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7888052
19 January 2024
Internal Structural Exam · Drydock Extension
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7857922
10 October 2023
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7806065
7 October 2023
Deficiency Check · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7805028
7 October 2023
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7818350
25 July 2023
Deficiency Check · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7751390
24 July 2023
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7752013
5 May 2023
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7681753
16 February 2023
Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7633296
13 December 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7608652
13 December 2022
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7629746
3 May 2022
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7442249
8 February 2022
Drydock Exam · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7393054
7 October 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7328832
29 July 2021
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7271988
6 January 2021
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7120763
20 October 2020
Plan Review (Other than "T") · In-Service Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7081319
14 April 2020
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6955390
2 December 2019
Administrative Inspection · Internal Structural Exam · Inclining Experiment · In-Service Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6865794
16 May 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6685114
23 January 2019
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6614267
23 January 2019
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6619947
20 October 2018
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6564785
19 October 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6572055
12 August 2018
In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6510909
12 August 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6511179
22 March 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6376311
20 March 2018
DAPI Audit · MTSA Verification · Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6374320
29 January 2018
Drydock Exam · Administrative Inspection · Plan Review (Other than "T") · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6345368
17 September 2017
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6281038
17 September 2017
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6324742
20 August 2017
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6251520
30 March 2017
Annual Inspection · MTSA/ISPS Verification · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6114353
17 February 2017
In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6090465
10 May 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5873281
4 March 2016
Internal Structural Exam · Examination of Repairs · Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5826927
27 January 2016
Internal Structural Exam · Drydock Extension
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5805732
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 May 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. The junction box located in the storage compartment behind the snack bar is misaligned.
46 CFR 120.200(b)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2026
Resolved 2 June 2026
Resolution: MI recieved picture from vessel rep of the junction box remounted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 May 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI discovered several dead end wires in the pilot house both underneath the back desk and under the port side of the operating station.
46 CFR 120.200(b)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2026
Resolved 2 June 2026
Resolution: MI received pictures from vessel rep of dead end wires capped.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 May 2026
Resolved
Each distribution panel or switchboard must be totally enclosed and of the dead front type. The electrical panel located in the starboard entrance to the engine room has holes, exposing interior wiring.
46 CFR 120.330(b)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2026
Resolved 2 June 2026
Resolution: MI recieved pictures from vessel rep of the holes in the breaked box covered.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 May 2026
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child life jackets were stored amongst adult life jackets.
46 CFR 117.78(a)(5)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2026
Resolved 2 June 2026
Resolution: MI recieved a picture from vessel rep of the child life jackets separated by a new divider.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 May 2026
Resolved
Each life jacket must be marked with Type I retroreflective material. Child life jackets were missing retroreflective material.
46 CFR 122.604(h)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2026
Resolved 2 June 2026
Resolution: MI recieved a picture from vessel rep of new retroreflective tape applied to the child life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 May 2026
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Child life jackets were not labeled with vessel's name.
46 CFR 122.604(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2026
Resolved 2 June 2026
Resolution: MI recieved pictures from vessel rep of fresh lettering applied to the child life jackets.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 7 May 2026
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 °C (150 °F), must be insulated where necessary to prevent injuries. Exhaust lagging was loose on port and starboard engines.
46 CFR 116.970
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2026
Resolved 2 June 2026
Resolution: MI recieved pictures from vessel rep of newly installed lagging on engine exhaust line.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 7 May 2026
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage. Port engine room entrance light cover was broken.
46 CFR 120.410(a)
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 7 May 2026
Resolution: Light cover was replaced while MI was onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 May 2026
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. First Aid kit did not contain aspirin.
46 CFR 121.710
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 May 2026
Resolution: New asprin was added to the first aid kit while MI was onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 29 April 2025
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material. Marine Inspector identified missing light fixtures on the port forward side of the engine room. Conduct repairs to the satisfaction of the Marine Inspector.
46 CFR 120.410(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 13 May 2025
Resolution: Light Fixtures replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 April 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to:(c) Minimize accidental personnel contact with energized parts. Marine Inspector identified an exposed breaker panel in the storage space on the main deck. Conduct repairs to the satisfaction of the Marine Inspector.
46 CFR 120.200(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 13 May 2025
Resolution: Breaker Panel Door repaired.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 April 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Marine Inspector identified exposed, dead-end wiring in the storage room on the main deck. Conduct repairs to the satisfaction of the Marine Inspector.
46 CFR 120.200(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 13 May 2025
Resolution: Wiring terminated in the electrical junction box.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 1 April 2024
Resolved
No major repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or
equipment, shall be made without the knowledge and approval of the Officer in Charge, Marine Inspection. Submit repair proposal for raw water intake piping reconfiguration, replacement of wasted frame in engine room, and exhaust discharge outlet reconfiguration. 46 CFR 176.20-1 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2024
Resolved 6 May 2024
Resolution: Exhaust and SW cooling mainfold replaced and tested IAW original spec, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 April 2024
Resolved
...Bilge suctions shall be fitted with suitable strainers having an open area not less than three times the area of the bilge pipe. Identify and replace non metallic bilge strainers within void 2, engine room, and steering gear spaces. 46 CFR 182.25-10(b) (OLD T)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 April 2024
Resolved 6 May 2024
Resolution: Bilge suction feet replaced with metallic feet/strainers, all sat.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 1 April 2024
Resolved
Examine all accessible parts of the exterior and interior of the hull...grind and remove coating on weld IVO inset on aft port bulkhead of steering void for inspection. 46 CFR 176.25-5(a)(1) (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2024
Resolved 9 April 2024
Resolution: Shipyard removed coatings and ground out cracks in weld, new weld seam applied to area.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 1 April 2024
Resolved
A periodic examination made in accordance with the requirements of this subpart shall include...through-hull fittings..and shall be of sufficient scope to determine that these items are in a satisfactory condition for the service intended. Remove 03 through-hull fittings in engine room for inspection. 46 CFR 175.15-5(a)(OLD T)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2024
Resolved 9 April 2024
Resolution: MI observed SAT function of through hull valves.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 October 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel experienced a loss of propulsion from their port electric motor drive. Diagnose the cause of the issue and make repairs to the satisfaction of the Marine Inspector.
46CFR119.200(a)
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 October 2023
Resolution: DMI visited the vessel to conduct Sea trials and oversee repairs. Both repairs and sea trials were found satisfactory. Vessel defiency and op control are cleared.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 July 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to provided services necessary for safety under normal and emergency conditions. While moored, vessel experienced a loss of primary electrical power. Provide cause analysis and effect repairs to the satisfaction of the marine inspector prior to the carriage of passengers for hire.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2023
Resolution: Verified repairs made and all systems working under full load.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 February 2023
Resolved
Electrical equipment must protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Dead end and loose wiring needs to be removed from unused electrical found on both sides of engine motors and fwd bilge area of engine room.
46 CFR 120.200(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2023
Resolved 28 February 2023
Resolution: Vessel sent pictures of removed wiring. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 16 February 2023
Resolved
A work space must provide suitable protection for the crew. Engine Room insulation contains spikes that need to be capped for protection of crew.
46 CFR 116.700(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2023
Resolved 28 February 2023
Resolution: Vessel sent pictures appropriately capped spikes. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 February 2023
Resolved
Electrical equipment must protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Vessel shall remove ecology dam pump and wiring since not in use and having loose wiring.
46 CFR 120.200(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2023
Resolved 28 February 2023
Resolution: Vessel sent pictures of removed ecology dam pump and wiring. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 February 2023
Resolved
All cable and wire must be installed with metal supports spaced not more than 24in apart. Cable and wires in the Lazarette are not properly supported and shall be supported as such.
46 CFR 120.340(b)(4)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2023
Resolved 28 February 2023
Resolution: Vessel sent pictures of installed appropriate wire supports. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 February 2023
Resolved
A life preserver must be of such construction, material, and workmanship that it can perform its intended function. Several life jackets could not properly hold retro tape due to no smooth and clean surface in appropriate location from age of the jacket. Several lifejackets are approaching 60 years old. Vessel shall formulate a replacement plan for severely aged lifejackets to ensure new, appropriately functioning lifejackets.
46 CFR 160.001-2(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2023
Resolved 28 February 2023
Resolution: Vessel developed plan to replace severely aged life jackets at an increment of 10% of them per calendar year, until all of the severely aged life jackets are replaced. ALL SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 December 2022
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its design limitations. Vessel reported loss of propulsion on starboard engine. Diagnose issue and make appropriate repairs.
46 CFR 182.200(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 December 2022
Resolution: MI's attended vessel and witnessed satisfactory repairs made to fuse.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 3 May 2022
Resolved
An interior or exterior opening that is temporarily closed by cover plates or boards held in place only by hooks bolts is considered open to the weather if battening, caulking, or gaskets of any material are not used. Port side main deck aft tonnage door has permanent rail and interior ramp affixed, preventing its removal. Repair by next credit drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 February 2024
Resolved 26 April 2024
Resolution: Verified removal of rail and ramp is not hindering tonnage opening removal.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 May 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 171 adult life jackets found with faded retro reflective tape or in unservicable condition. Vessel restricted to carrying 640 adult passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2022
Resolved 13 May 2022
Resolution: Received email and photos for correction to PFDs.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 February 2022
Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable. Vessel has dissimilar fire stop on after bulkhead penetration for cable run in battery storage room.
46 CFR 177.10-5(a) "Old T" L
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 28 March 2022
Resolution: Cable run firestop of same type.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 October 2021
Resolved
Whenever machinery is installed aboard a vessel after completion of the initial inspection for certification of the vessel, as replacement equipment or as a new installation, the owner shall conduct the tests and make the vessel ready for inspection to the satisfaction of the cognizant OCMI. The vessel self reported that one of the main propulsion electric motors is being replaced in kind due to excessive vibration. The vessel must conduct an operational test of the main propulsion electric motor to the satisfaction of the attending Marine Inspector.
46CFR115.702
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 October 2021
Resolution: Conducted operational tests while underway to the satisfaction of the attending Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 6 January 2021
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material. Three lights in lazarette and one in forepeak missing guard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 February 2021
Resolved 23 April 2021
Resolution: Verified guards over lighting in place.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 6 January 2021
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date US Coast Pilot or similar publication. Copy of Navigation Rules onboard was not up to date.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 January 2021
Resolved 6 January 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 January 2021
Resolved
All microprocessor or computer based systems must meet the requirements of part 62 in subchapter F of this chapter. Line item 11 of DVTP indicates during engine overspeed, engine will shutdown. While operating in dual mode, engines will attempt to restart 3 times before completely shutting down. Amend DVTP's to reflect engine operation during overspeed or update system to comply with current DVTP's.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 February 2021
Resolved 23 April 2021
Resolution: Witnessed testing in accordance with DVTP.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 20 October 2020
Resolved
Penetrations in A-Class fire control boundaries for electrical cables must be constructed to prevent the passage of flame and smoke for one hour. Six areas noted in aft battery void (3 on each end of forward/aft bulkheads near centerline) where multi cable transits were missing structural fire protection.
46 CFR 116.415(a)(2)(ii)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2020
Resolved 18 November 2020
Resolution: Verified portion on site and remaining via photos.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 October 2020
Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Battery bank in aft battery void connected to inverter fues & disocnnect had connections to the terminal made with wing-nuts.
46 CFR 120.350(d)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2020
Resolved 6 November 2020
Resolution: Wingnuts replacd with permanent connectors.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 17 January 2020
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the OCMI may require the vessel to effect permanent repairs. Voids 3 and 4 found with several wasted areas related to framing and bottom plate.
Provide repair proposal and affect proper repairs.
46 CFR 115.600(d)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 February 2020
Resolved 6 February 2020
Resolution: Witnessed satisfactory repairs.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 2 December 2019
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the OCMI may require the vessel to effect permanent repairs. Needle gunning bottom plate beneath starboard engine revealed three holes that penetrated the shell. Provide repair proposal and affect proper repairs.
46 CFR 115.600(d)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2020
Resolved 3 December 2019
Resolution: Witnessed satisfactory repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 October 2018
Resolved
All machinery must be maintained in such a manner to afford protection from machinery failure. Starboard Reduction Gear Lube Oil Cooler failed causing oil to leak into salt water cooling system. Repair reduction gear lube oil cooler prior to the carriage of passengers.
46 CFR 182.100
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 October 2018
Engineering › Bilge Water Management System › Piping
Issued 29 March 2018
Resolved
Make permanent repairs to void #4 bilge piping at strainer currently utilizing a marine grade hose.
Action required: 705 - Other - as specified
Due 29 April 2018
Resolved 16 May 2019
Resolution: Vessel properly repaired bilge strainer.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 27 March 2018
Resolved
Demonstrate satisfactory MOB drill to a Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2018
Resolution: Sat MOB drill witnessed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 22 March 2018
Resolved
Vessel has expired COI & must complete 5-YR inspection IAW 46 CFR 115.107.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2018
Resolved 22 March 2018
Engineering › Electric Propulsion System › Bus
Issued 17 September 2017
Resolved
Vessel suffered propulsion reduction while underway due to failure with starboard insulated gate bipolar transistor inside starboard propulsion module.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 September 2017
Resolved 18 September 2017
Resolution: Crew replaced and tested module with satisfactory results.
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 17 February 2017
Resolved
Reinstall 02 100-person IBAs as per vessel's COI. The vessel is allowed to continue operations as long as it remains compliant with the San Francisco Vessel Mutual Assistance Program. - 46 CFR 117.200
Action required: 705 - Other - as specified
Due 17 March 2017
Resolved 30 March 2017
Resolution: Operator submitted photos to unit, which was verified during Annual Inspection.