Inspection history · 41
16 July 2025
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8210831
6 June 2025
COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8135261
1 October 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8012379
12 July 2024
Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7956776
5 December 2023
Drydock Exam · Deficiency Check · Hull Examination · Internal Structural Exam · Plan Review (Other than "T")
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7833936
27 July 2023
Internal Structural Exam · Hull Examination · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7753627
7 October 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7560490
15 September 2021
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7334979
9 July 2020
Initial Certification · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7000983
15 October 2019
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6847354
6 October 2019
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6835991
11 October 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6559035
2 February 2017
Examination of Repairs · Construction Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6081737
19 August 2016
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5977365
14 August 2016
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5973735
14 August 2016
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6013558
21 May 2015
Marine Casualty Follow Up
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5131165
20 October 2013
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4759300
31 May 2011
Deficiency Check · Industry Initiated Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4023923
21 April 2011
DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4032910
3 February 2011
Deficiency Check · Administration
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3942171
21 December 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3941565
29 April 2010
Type not recorded
No type recorded · USCGC TERN (WPB 87343) · USCG Southwest District (CGD-SW) · Activity 3740753
18 October 2006
MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2802653
3 August 2006
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2735960
3 August 2006
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2739007
25 March 2006
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2650604
10 June 2005
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2396807
6 January 2005
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2284430
17 November 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2252245
24 February 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2024828
28 October 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 35816
10 May 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 230283
12 November 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 77347
13 March 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 111586
30 November 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1003
23 July 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 17646
13 November 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 760238
9 October 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 208267
7 September 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 23178
22 October 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 115829
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 6 June 2025
Resolved
All lifesaving equipment must be tested and maintained in accordance with the minimum requirements of 46 CFR 199.190 of this chapter, as applicable. MI found vessel's liferaft expired. Vessel's route is restricted to Lakes, Bays, and Sounds and not authorized to carry persons in addition to crew until lifesaving meets the requirements for the COI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2025
Resolved 18 July 2025
Resolution: O/O provided satisfacotry liferaft servicing certificate for 06 person liferaft. COI amended to reduce persons permitted on board from 08 to 06.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 June 2025
Resolved
Each towing vessel must carry at least one appropriately-sized lifejacket, approved under approval series 160.002, 160.005, 160.055, 160.155, 160.176, or 160.255 for each person on board. MI observed vessel had 06 lifejackets onboard instead of the required 08 at the time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2025
Resolved 18 July 2025
Resolution: COI amended to reduce total person onboard from 08 to 06. Vsl now satisfactorily meets minimum lifejacket requirement.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 6 June 2025
Resolved
Each towing vessel operating north of lat. 32° N. or south of lat. 32° S. must carry at least one appropriate-size immersion suit, approved under approval series 160.171, for each person onboard. MI observed vessel had 06 of the required 08 immersion suits at the time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2025
Resolved 18 July 2025
Resolution: COI amended to reduce total person onboard from 08 to 06. Vsl now satisfactorily meets minimum immersion suit requirement.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 6 June 2025
Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040. MI observed vessel had 03 of the required 04 line throwing appliances required by 46 CFR 160.040.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2025
Resolved 18 June 2025
Resolution: Vessel representative provided invoice attesting to purchase of an additional 03 line throwing devices, satisfying minimum requirement of 04.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 October 2024
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Marine inspector found 2 batteries in the pilot house that were not secured. Secure batteries and send pictures to local OCMI.
46 CFR 143.205
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2024
Resolved 16 October 2024
Resolution: Received photos on secured battery box. ALL SAT.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 May 2024
No resolution recorded
An existing vessel may be deemed by the OCMI, or TPO, to be in compliance with this subpart provided that either: The vessel has been both in satisfactory service insofar as structural adequacy is concerned and does not cause the structure of the vessel to be questioned by either the OCMI, or TPO engaged to perform an audit or survey. Effect permanent repairs to port and starboard fuel tanks to the satisfaction of local OCMI prior to conducting commercial operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 March 2024
Resolved
An existing vessel may be deemed by the OCMI, or TPO, to be in compliance with this subpart provided that either: The vessel has been both in satisfactory service insofar as structural adequacy is concerned and does not cause the structure of the vessel to be questioned by either the OCMI, or TPO engaged to perform an audit or survey. Wastage found in port fuel tank overhead running forward to aft along port outboard side and throughout the entire starboard fuel tank overhead. Provide repair proposal and affect proper repairs to the satisfaction of attending marine inspector prior to credit drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 May 2024
Resolution: Temp repair affected. Separate 835 issued for permanent repair.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 27 July 2023
Resolved
STBD Lazarette between deck frames 1-3 from the outboard hull inboard approx 3 ft found to be severely wasted. Crop and renew wasted area.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2023
Resolved 5 September 2023
Resolution: Cropped and renewed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 27 July 2023
Resolved
STBD Lazarette No.1 deck frame from the outboard hull inboard approx 3 ft found to be severely wasted. Crop and renew wasted area.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2023
Resolved 5 September 2023
Resolution: Cropped and renewed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 27 July 2023
Resolved
STBD Lazarette entrance combing IWO hatch found to be severely wasted. Crop and renew wasted area.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2023
Resolved 5 September 2023
Resolution: Cropped and renewed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 27 July 2023
Resolved
Port Lazarette between deck frames 1-2 from outboard hull to approx 2' inboard found to be severely wasted. Crop and renew.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2023
Resolved 5 September 2023
Resolution: Cropped and renewed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 27 July 2023
Resolved
Port Lazarette between deck frame 3-4 from outboard hull to approx. 6' inboard found to be severely wasted. Crop and renew wasted area.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2023
Resolved 5 September 2023
Resolution: Cropped and renewed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 27 July 2023
Resolved
Port Lazarette verticle frame no.1 found to be severely wasted. Crop and renew wasted area.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 July 2023
Resolved 5 September 2023
Resolution: Cropped and renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 July 2023
Resolved
Each towing vessel must have a reliable means to provide
notification when an emergency condition exists or an
essential system develops problems that require
attention. The bilge pump in the lazarette filed to
alarm during test. Fix bilge alarm and any associated
components.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 September 2023
Resolved 14 September 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 27 July 2023
Resolved
Each towing vessel equipped with rudder(s) must have a
means to monitor and control the position of the rudder
(s) at each operating station. The rudder angle
indicator was inoperable. Repair rudder angle indicator
and prove a satisfactory test.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 September 2023
Resolved 14 September 2023
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 27 July 2023
Resolved
The master of a towing vessel must ensure that drills
are conducted and instructions are given to ensure that
all crew- members are capable of performing the duties
expected of them during emergencies. This includes
abandoning the vessel, recovering persons from the
water, responding to onboard fires and flooding, or
responding to other threats to life, property, or the
environment. Was unable to get vessel underway due to
the bilge and rudder angle indicator being inoperable.
Conduct drill when issues are corrected.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 September 2023
Resolved 14 September 2023
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 7 October 2022
Resolved
The following vessels must have on board a properly installed and operational Coast Guard type-approved AIS class A device: A towing vessel of 26 feet or more engaged in commercial service. Vessel was unable to demonstrate proper operation of marine radar and AIS.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2022
Resolved 12 October 2022
Resolution: MI witnessed proper operation of the vessel's AIS and radar.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 7 October 2022
Resolved
Each towing vessel operating in oceans and coastwise service must have a line throwing appliance approved under approval series 160.040. Vessel only has three of the required four rocket projectiles.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2022
Resolved 12 October 2022
Resolution: Vessel has obtained a fourth rocket projectile.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 October 2022
Resolved
Each towing vessel must be equipped with an industrial first aid cabinet or kit, appropriate to the size of the crew and operating conditions. Vessel has several items in their first aid kits/cabinets that are expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2022
Resolved 12 October 2022
Resolution: Vessel has replaced all expired first aid kit items.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 7 October 2022
Resolved
Survival craft must be stowed in accordance with the requirements of 46 CFR 199.130. Vessel's inflatable life raft was not properly secured.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 7 October 2022
Resolved 7 October 2022
Resolution: MI witnessed vessel's master properly secure the life raft.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 7 October 2022
Resolved
The following list of items must be recorded in the TVR or official logbook: record of drills and instruction and navigation assessment. Vessel was not maintaining adequate logs and required record keeping. MI explained record keeping and logging requirements with the vessel's master.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 October 2022
Resolved 7 October 2022
Resolution: MI conducted training with vessel's master on procedures for proper logbook entries and recordkeeping.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 September 2021
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Engine room electrical “Panel A” missing circuit breaker covers leaving panel exposed to electrical hazards and circuit directory not updated.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 22 September 2021
Resolution: Def cleared by attending MI
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 September 2021
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Engine room electrical “Panel A” missing circuit breaker covers leaving panel exposed to electrical hazards and circuit directory not updated.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 22 September 2021
Resolution: Def cleared by attending MI
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 September 2021
Resolved
ENG room aft bulkhead through pipe penetrations not properly sealed.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 22 September 2021
Resolution: Def cleared by attending MI
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 11 October 2018
Resolved
IMO: Vsl is broadcasting no IMO #, LENGTH DIFF: greater/smaller than expected vessel length
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 13 August 2020
Resolution: Vessel updated AIS information.
Documentation › Logs/Records › Drug Test Records
Issued 21 April 2011
Resolved
Testing is not spread equally throughout the year as required by 46 CFR 16.230.
Due 22 May 2011
Resolved 21 April 2011
Resolution: DER education and training conducted.
Documentation › Logs/Records › Drug Test Records
Issued 21 April 2011
Resolved
MIS form not submitted by March 15 as required by 46 CFR part 16.500.
Due 22 May 2011
Resolved 16 May 2011
Resolution: DER completed and emailed DAPI a copy of 2010 MIS form.