MAURY USCG vessel records
← All vessels

BAYCAT

Built
1980
Last inspected
8 July 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 8 July 2025
…with no type recorded10
Operational controls None recorded without a removal date
Years with a record 22 calendar years (1989–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDA9210
189865
Flag
UNITED STATES
Maury page id
psix-189865

Documentation record

Registered dimensions (L × B × D)55.5 ft × 22.1 ft × 8.2 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSCULLY BROS BOAT BLDG INC · STEPHENSVILLE LA, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 25 June 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 30 inspections, each with its date, unit and type; 25 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 13 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 13

Inspection history · 30

8 July 2025 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8173513
26 August 2024 Deficiency Check · Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7985279
8 August 2024 DAPI Audit · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7965047
18 May 2024 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7922655
20 November 2023 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7811171
18 August 2022 Hull Examination · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7537178
28 July 2022 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7518549
28 September 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7321486
25 September 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7067144
24 September 2020 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7065125
6 August 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7025898
8 July 2019 Initial Certification · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6742369
23 August 2017 Industry Initiated Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6250723
9 September 2015 MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5720606
12 June 2014 Deficiency Check · Industry Initiated Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4886785
3 May 2013 DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4586580
12 April 2012 MTSA/ISPS Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4287934
16 May 2011 Industry Initiated Exam · Deficiency Check · MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3997339
21 March 2011 DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3976249
23 March 2010 DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3701512
11 August 2007 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3043277
7 November 2006 MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2815668
25 March 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2650604
23 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978359
31 December 2002 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1725873
15 July 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 72464
8 July 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 184453
10 November 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 19462
19 July 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 514
15 May 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 464033

Deficiency record · 25

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 July 2025 Resolved
Electrical equipment and electrical cables must be suitably protected from wet and corrosive environments. Stbd/aft deck light on 2nd deck railing was broken off/missing leaving a large hole in the associated housing for wiring exposed to weather. Repair or replace electrical wiring housing/box to satisfaction of MI. 46 CFR 143.400(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2025
Resolution: Received photos of replaced housing for wiring for broken deck light.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 August 2024 Resolved
The inspection will ensure that the vessel is in satisfactory condition and fit for the service for which it is intended. The lazarette compartment was not made available for inspection. Make available for inspection prior credit dry dock exam. 46 CFR 136.212(b)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 26 August 2024
Resolution: Vessel was able to make available the lazarette during the vessel's drydock, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 August 2024 Resolved
There must be an installed or portable bilge pump for emergency dewatering. All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended back flooding through bilge piping. Bilge suction servicing the lazarette compartment was not made available for testing. Visually inspect and test lazarette bilge suction prior to credit dry dock exam. 46 CFR 143.275
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 13 September 2024
Resolution: Verified operation of bilge suction in lazarette.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 August 2024 Resolved
The inspection will ensure that the vessel is in satisfactory condition and fit for the service for which it is intended. Excessive oil and debris found in the Engine Room bilges. Make available for inspection prior credit dry dock exam. 46 CFR 136.212(b)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 26 August 2024
Resolution: Vessel cleaned the engine room bilge making available for inspection during the vessel's drydock.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 8 August 2024 Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel... Starboard forward hatch gasket was worn, replace gasket to the satisfaction of the Marine Inspector. 46 CFR 144.320(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2024
Resolved 5 September 2024
Resolution: Verified repalced gasket.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 August 2024 Resolved
Stowage positions for lifejackets stowed in a berthing space or stateroom and all lifejacket containers must be marked in block capital letters and numbers with the minimum quantity. Life jacket storage was improperly labeled, correct label to reflect accurate number of lifejackets. 46 CFR 141.340(h)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2024
Resolved 26 August 2024
Resolution: Vessel operator properly labled the stowage of the vessel's lifejackets.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 8 August 2024 Resolved
Emergency lighting must be provided for all internal crew working and living areas. Emergency lighting sources must provide for sufficient illumination under emergency conditions to facilitate egress from each space. Emergency lighting located in the pilothouse found to be inoperable. Replace emergency lighting to the satisfaction of the Marine Inspector. 46 CFR 143.410(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2024
Resolved 5 September 2024
Resolution: Verified operation of e-lighting.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 August 2024 Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Steering gear motor controller found with missing reset button. Restore functionality to the satisfaction of the Marine Inspector. 46 CFR 143.400(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2024
Resolved 5 September 2024
Resolution: Verified replaced reset button.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 August 2024 Resolved
The Rules concerning shapes shall be complied with by day. Vessel did not have any day shapes on board. Procure and place day shapes applicable to the vessel on board. 33 CFR 83.20(d)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2024
Resolved 13 September 2024
Resolution: Accepted photos of day shapes onboard.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 8 August 2024 Resolved
A crew accommodation space and a work space must be of sufficient size, adequate construction, and with suitable equipment to provide for the safe operation of the vessel and the protection and accommodation of the crew in a manner practicable for the size, facilities, service, route, and modes of operation of the vessel. Grey water pipe from crew accommodation space is leaking into the engine room. Repair piping to the satisfaction of the Marine Inspector. 46 CFR 144.700(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2024
Resolved 5 September 2024
Resolution: Verified replaced piping.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 August 2024 Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. The tests required by this section must be recorded in accordance with part 140 of this subchapter. Vessel had no records of testing the relief valves on their two UPVs. Vessel conducted satisfactory tests in the presence of the MI. 46 CFR 143.245(b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 August 2024
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 20 November 2023 Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover. The starboard side remote fuel shutoff valve is not operable. Either repair or remove remote fuel shutoff to the satisfaction of the attending Marine Inspector. 46 CFR 143.260(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2023
Resolved 28 December 2023
Resolution: Received video of repaired fuel shut off
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 November 2023 Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. The port fidley circuit breaker number 41 is labeled as a spare but has an active load. Properly label the circuit breaker to the satisfaction of the attending Marine Inspector. 46 CFR 143.400(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2023
Resolved 27 December 2023
Resolution: Operator provided photo of breaker with no wire running to it.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 20 November 2023 Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. The starboard watertight door to the machinery space is not watertight. Ensure watertight integrity of the door to the satisfaction of the attending Marine Inspector. 46 CFR 140.610(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2023
Resolved 28 December 2023
Resolution: Received photo of closed WTD.
02 - Structural Conditions › N/A - No Subsystem › Permanent means of access
Issued 20 November 2023 Resolved
The vessel is built, equipped, and maintained to conform to the rules of a recognized classification society appropriate for the intended service and routes. The ladder to the fly bridge is severely wasted at its mounting points. Make repairs to the satisfaction of the attending Marine Inspector. 46 CFR 144.200(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2023
Resolved 28 December 2023
Resolution: Received photo of repaired ladder.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 28 September 2021 Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR-KEEP CLOSED” or “WATERTIGHT HATCH-KEEP CLOSED”. All main deck watertight doors are missing appropriate signage.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2021
Resolved 26 October 2021
Resolution: Verified required signage on water tight doors.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 28 September 2021 Resolved
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. Port engine room door and Stbd door to galley are not watertight.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2021
Resolved 26 October 2021
Resolution: Verified that both doors were watertight and functional.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 September 2021 Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. Number labels on the distribution panel for in the engine room fiddley are not legible.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2021
Resolved 26 October 2021
Resolution: Verified that all circuit breakers on the distribution panels were properly labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 September 2021 Resolved
Each towing vessel must be equipped with a means to detect smoke in the berthing spaces and lounges by an installed detecting system or by using individual battery operated detectors meeting UL 217. Galley detector was not UL 217 rated.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2021
Resolved 27 October 2021
Resolution: Operator submitted photos showing that the smoke detector was UL 217 rated.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 28 September 2021 Resolved
Each vessel must be designed and constructed to minimize fire hazards insofar as reasonable and practicable. Engine room stack has two closures with no means to secure in the event of a fire.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2021
Resolved 27 October 2021
Resolution: Operator submitted photo displaying securing arrangements.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 28 September 2021 Resolved
Each mattress must comply with either The Consumer Safety Commission Standard for Mattress Flammability or IMO Resolution A.688(17). Vessel mattresses did not have indication they meet flammability requirements. Provide verification mattresses meet correct standards or replace.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2021
Resolved 27 October 2021
Resolution: Operator submitted photo verifying that the mattresses met the required flammability requirements.
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 28 September 2021 Resolved
Each towing vessel must be capable of preventing all oil spills from reaching the water during transfers by: using fixed or portable containment of sufficient capacity. Port fuel fill containment missing plug.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2021
Resolved 27 October 2021
Resolution: Operator submitted photo of the fuel containment plug installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 28 September 2021 Resolved
Rails or equivalent protection must be installed near the periphery of all decks accessible to crew. Bridge deck, port forward rail has two wasted stanchions requiring repair by next credit drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2022
Resolved 18 August 2022
Resolution: cleared deficiency during dry dock examination.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 August 2020 Resolved
Electrical systems and equipment must function properly and minimize system failuires and shock hazards. The cover for the electrical panel on the bridge would not properly shut and poses a hazard to crew.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2020
Resolved 10 August 2020
Resolution: Verified via pictures
Documentation › Logs/Records › Drug Test Records
Issued 23 March 2010 Resolved
Company does not have a Substance Abuse Professional (SAP) name and contact information, as required by 49 CFR 40.287.
Due 23 April 2010
Resolved 23 March 2010

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.