MAURY USCG vessel records Sign in
← All vessels

DIAMOND HIGHWAY

DIAMOND HIGHWAY is a 2004 freight ship. The Coast Guard has recorded 22 inspections since 2004, most recently in April 2019, along with 7 deficiencies.

Records from 2004 to 2019. Most recent: inspection, 15 April 2019.

Built
2004
Last inspected
15 April 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9293636 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
721712
Flag
PANAMA
—
Maury page id
psix-721712

Inspections, by type

…with no type recorded7
Years with a record 11 calendar years (2004–2019)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it60175 - Regulatory (Subpart C or D), Gross Ton
60175 - Convention (Subpart B), Gross Ton
18575 - Regulatory (Subpart C or D), Net Ton
19086 - Dead Weight, Ton
18575 - Convention (Subpart B), Net Ton
34173 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

STODDARD SEA Tank Barge · MISLE 850408 · 2 December 2011 · activity 4202018

Inspection history · 22

15 April 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6662694
14 February 2019 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6623857
16 June 2018 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6446143
16 April 2018 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6392388
18 December 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6323643
28 August 2016 Administrative Inspection · ISPS II Exam · Deficiency Check · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5976321
19 June 2014 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4893444
28 May 2014 PII Safety Exam · Ballast Water Examination · Deficiency Check · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4867496
2 December 2011 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4195362
2 December 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4202018
16 October 2008 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3345718
6 January 2008 Random ISPS/MTSA/PSC
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3125511
26 December 2007 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3121090
26 April 2007 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2916183
20 April 2007 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2911916
29 June 2006 Ballast Water Examination · Random ISPS/MTSA/PSC · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2693069
29 June 2006 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2695121
30 October 2005 MARPOL Annex V Examination · NPV Safety Exam · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2524702
1 July 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2409936
27 June 2005 Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2404913
13 October 2004 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2220565
23 September 2004 MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2203344

Deficiency record · 7

08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 14 February 2019 Resolved
Hydraulic power-operated steering gear shall be provided with a low-level alarm for each hydraulic fluid reservoir. The low-level alarm for the port side hydraulic fluid reservoir (number two) could not be demonstrated as operational. 16ac SOLAS74(04) II-1/29.12.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2019
Resolved 2 March 2019
Resolution: Vessel sent class report attesting to repairs.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 14 February 2019 Resolved
No change shall be made in the equiptment, systems, fittings, arrangements, or materials covered by the survey, after survey. Port State Control Officer observed that the normal operation of the incinerator could not be demonstrated by ships crew and sustain combustion. 16ac MARPOL Annex 1 ch.2, Reg6.4.2 and ch.3, Reg 12.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2019
Resolved 2 March 2019
Resolution: Received class report attesting to repairs
Navigation › Collision/Grounding Avoidance › Transponder
Issued 28 August 2016 Resolved
1520-Shipboarn Navigational equipment-All ships of 300 gross tonnage and upwards engaged on international voyages and cargo ships of 500 gross tonnage and upwards not engaged on international voyages and passenger ships irrespective of size shall be fitted with an automatic identification system (AIS). Vessels AIS was inoperable. 74 SOLAS 2014 con. V-19.2.4.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2016
Resolution: Received class report from NKK attesting to repair of AIS.
Fire Fighting › Fixed High-Expansion Foam Fire Extinguishing System › Operation Controls
Issued 28 May 2014 Resolved
A fixed high-expansion foam fire extinguishing system shall comply with the provisions of the F.S.S. Code. Vessel unable to provide record of annual foam analysis (74 SOLAS (04) II-2, Reg 10/4.1.1.2; REF F.S.S. Code, Ch 6/2.2.1.1) (50c). 16c Amended to 50c
Action required: 705 - Other - as specified
Due 27 June 2014
Resolved 19 June 2014
Resolution: Received satisfactory foam analysis report.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 27 June 2005 Resolved
Emergency Generator space ("A" class machinery space) and bordering mess cook stateroom (an accommodation space) does not have automatic fire dampers close to the boundaries.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 30 October 2005
Resolution: Jacksonville PSCO reviewed NKK Class report attesting to satisfactory resolution of deficiency: Emergency Generator Space is not classified as machinery space; classified as Control Space, obviating requirement for automatic dampers.
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 27 June 2005 Resolved
Fire detector mounting above incinerator was removed and replaced with a wire to eliminate nuisance alarm. Not reported via safety management system.
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Resolved 30 October 2005
Resolution: Sector Jacksonville PSCO observed fire detector mounted in place. Observed satisfactory test of fire detection system.
Operations/Management › Drills/Instruction › Fire
Issued 27 June 2005 Resolved
Inadequate fire drill procedure. Fought grease fire with water, failed to secure ventilation and power.
Action required: 705 - Other - as specified
Due 27 June 2005
Resolved 27 June 2005
Resolution: Fire drill conducted again satisfactorily.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.