Records from 2004 to 2019. Most recent: inspection, 15 April 2019.
Inspection history · 22
15 April 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6662694
14 February 2019
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6623857
16 June 2018
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6446143
16 April 2018
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6392388
18 December 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6323643
28 August 2016
Administrative Inspection · ISPS II Exam · Deficiency Check · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5976321
19 June 2014
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4893444
28 May 2014
PII Safety Exam · Ballast Water Examination · Deficiency Check · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4867496
2 December 2011
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4195362
2 December 2011
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4202018
16 October 2008
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3345718
6 January 2008
Random ISPS/MTSA/PSC
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3125511
26 December 2007
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3121090
26 April 2007
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2916183
20 April 2007
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2911916
29 June 2006
Ballast Water Examination · Random ISPS/MTSA/PSC · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2693069
29 June 2006
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2695121
30 October 2005
MARPOL Annex V Examination · NPV Safety Exam · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2524702
1 July 2005
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2409936
27 June 2005
Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2404913
13 October 2004
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2220565
23 September 2004
MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2203344
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 14 February 2019
Resolved
Hydraulic power-operated steering gear shall be provided with a low-level alarm for each hydraulic fluid reservoir.
The low-level alarm for the port side hydraulic fluid reservoir (number two) could not be demonstrated as operational. 16ac
SOLAS74(04) II-1/29.12.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2019
Resolved 2 March 2019
Resolution: Vessel sent class report attesting to repairs.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 14 February 2019
Resolved
No change shall be made in the equiptment, systems, fittings, arrangements, or materials covered by the survey, after survey.
Port State Control Officer observed that the normal operation of the incinerator could not be demonstrated by ships crew and sustain combustion. 16ac
MARPOL Annex 1 ch.2, Reg6.4.2 and ch.3, Reg 12.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2019
Resolved 2 March 2019
Resolution: Received class report attesting to repairs
Navigation › Collision/Grounding Avoidance › Transponder
Issued 28 August 2016
Resolved
1520-Shipboarn Navigational equipment-All ships of 300 gross tonnage and upwards engaged on international voyages and cargo ships of 500 gross tonnage and upwards not engaged on international voyages and passenger ships irrespective of size shall be fitted with an automatic identification system (AIS). Vessels AIS was inoperable. 74 SOLAS 2014 con. V-19.2.4.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2016
Resolution: Received class report from NKK attesting to repair of AIS.
Fire Fighting › Fixed High-Expansion Foam Fire Extinguishing System › Operation Controls
Issued 28 May 2014
Resolved
A fixed high-expansion foam fire extinguishing system shall comply with the provisions of the F.S.S. Code. Vessel unable to provide record of annual foam analysis (74 SOLAS (04) II-2, Reg 10/4.1.1.2; REF F.S.S. Code, Ch 6/2.2.1.1) (50c).
16c
Amended to 50c
Action required: 705 - Other - as specified
Due 27 June 2014
Resolved 19 June 2014
Resolution: Received satisfactory foam analysis report.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 27 June 2005
Resolved
Emergency Generator space ("A" class machinery space) and bordering mess cook stateroom (an accommodation space) does not have automatic fire dampers close to the boundaries.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 30 October 2005
Resolution: Jacksonville PSCO reviewed NKK Class report attesting to satisfactory resolution of deficiency: Emergency Generator Space is not classified as machinery space; classified as Control Space, obviating requirement for automatic dampers.
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 27 June 2005
Resolved
Fire detector mounting above incinerator was removed and replaced with a wire to eliminate nuisance alarm. Not reported via safety management system.
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Resolved 30 October 2005
Resolution: Sector Jacksonville PSCO observed fire detector mounted in place. Observed satisfactory test of fire detection system.
Operations/Management › Drills/Instruction › Fire
Issued 27 June 2005
Resolved
Inadequate fire drill procedure. Fought grease fire with water, failed to secure ventilation and power.
Action required: 705 - Other - as specified
Due 27 June 2005
Resolved 27 June 2005
Resolution: Fire drill conducted again satisfactorily.