Records from 2007 to 2025. Most recent: inspection, 14 January 2025.
Inspection history · 22
14 January 2025
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8063302
30 December 2024
Administrative Inspection
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 8053012
28 October 2024
MTSA/ISPS Verification · Deficiency Check · In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8025615
26 October 2024
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8026695
23 July 2024
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7964188
16 May 2024
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7915763
6 May 2024
Deficiency Check · Permit to Proceed · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7907657
29 April 2024
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7903465
3 February 2024
ACP Additional Oversight – Risk Assessment · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7860099
26 October 2023
Administrative Inspection · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7814965
13 September 2023
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7791338
11 September 2023
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7789288
16 May 2023
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7677283
23 March 2023
Re-Inspection · Deficiency Check · Administrative Inspection · ACP COI Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7663543
2 December 2019
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6879114
26 March 2019
Annual Inspection · ACP Annual Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6649695
19 March 2019
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6645525
22 March 2018
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6376946
20 March 2018
Administrative Inspection · Periodic Inspection · ACP Periodic Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6374988
29 June 2017
ACP Annual Oversight · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6190630
16 November 2016
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6042339
17 May 2016
Annual Inspection · ACP Annual Oversight · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5879820
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 October 2024
Resolved
Efficient guard rails or bulwarks shall be fitted to all
exposed parts of the freeboard and superstructure decks.
The height of the bulwarks or guard rails shall be at
least 1m (39 ½”) from the deck.
Bulwarks on stern of vessel are missing.
Action required: 60 - Rectify deficiencies prior to movement
Due 29 October 2024
Resolved 31 October 2024
Resolution: Accepted as Condition of Class.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 28 October 2024
Resolved
All hatchways in position 1 and position 2 shall be
fitted with hatch covers of steel ... [and the] covers
shall be weathertight. The means for securing and
maintaining weathertightness shall be to the
satisfaction of the Administration. The arrangements
shall ensure that the tightness can be maintained in any
sea conditions.
Emergency escape hatch from starboard Z-drive room is
seized and cannot be closed.
Action required: 60 - Rectify deficiencies prior to movement
Due 29 October 2024
Resolved 31 October 2024
Resolution: Accepted as condition of class.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 28 October 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects is safe to proceed to sea without danger to the ship or persons on board.
Vessel has an approximately a 6 inch hole burned through port side aft main deck in way of Z-Drive Room.
Action required: 60 - Rectify deficiencies prior to movement
Due 29 October 2024
Resolved 31 October 2024
Resolution: Accepted as condition of class.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 23 July 2024
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including of openings and penetrations in these divisions. Engine Room ventilation damper would not close.
74SOLAS(20)II-2/14.2.1
Action required: 60 - Rectify deficiencies prior to movement
Due 23 July 2024
Resolved 25 July 2024
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 July 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Port day tank remote fuel valve inop.
74SOLAS(20)I/11(a)
Action required: 60 - Rectify deficiencies prior to movement
Due 23 July 2024
Resolved 25 July 2024
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 23 July 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Public Address System did not operate in a
all accommodation, engineering spaces and PAMs.
74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 25 July 2024
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 23 July 2024
Resolved
An onboard means of recharging breathing apparatus cylinders used during drills shall be provided or suitable number of spare cylinders shall be carried on board to replace those used. No spares or recharging capabilities onboard.
74SOLAS(20)II-2/15.2.2.6
Action required: 60 - Rectify deficiencies prior to movement
Due 23 July 2024
Resolved 25 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 July 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Port Z drive has reoccurring steering failure alarms due to brake chopper on the #1 steering motor.
74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition of class.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 July 2024
Resolved
Fire protection systems shall be kept in good working order so as to ensure their performance if a fire occurs: structural fire protection. Stair tower door leading to EOS missing latch and handle.
74SOLAS(20)II-2/14.2.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition class.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 23 July 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. STBD Potable water piping has patch with belzona and a hose clamp.
74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition of class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 July 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. #2 Diesel Generator (Harbor Generator) is missing speed sensor and will not stay running.
74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as Condition of Class.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 July 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. STBD Vent Duct outboard of no.3 diesel generator is being held in place with rope.
74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condtion of class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 July 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Vessel could not locate automation testing procedures or provide proof of completion.
74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition of class.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 July 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Red Rotating Alarm lights in Machinery Spaces & Tank Farm were not operational.
74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition of class
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 23 July 2024
Resolved
The activation of any detector or manual operated call point shall initiate visible and audible fire signal at control panel. If signals have not received attention with in 2 mins, an audible alarm shall automatically be sounded throughout the crew accommodations, service stations, control stations and machinery spaces of cat A. Fire Alarm purposely was left unacknowledged to test and alarm did not sound through out spaces after 3 minutes.
74SOLAS(09)II-2-7.2.2
FSS Code(07) 2.5.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition of class.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 23 July 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Public Address speaker hanging from wire in Z-Drive Room & Bow thruster space.
74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition of class.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 23 July 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Red rotating alarm beacon on port side is hanging from wire in Z-Drive room not properly mounted.
74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition of class.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 23 July 2024
Resolved
A means of communication should be provided between then Navigation Bridge and Steering gear compartment. Sound Powered Phone cable was not long enough could not reach the viewable vantage point for either Z drives controls.
74SOLAS(04) II-1 29.10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as conditon of class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 July 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Both steering pump motor housings not properly secured/vibrating.
74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condtion of class.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 23 July 2024
Resolved
Power-operated steering gear shall be provided with the following: A low level alarm for each hydraulic fluid reservoir to give the earliest indication of hydraulic fluid leakage. Vessel could not test or demonstrate operation of alarm.
SOLAS (04) II-1/29.12.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condtion of class.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 July 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Emergency Fire Pump sea chest vent pipe had temporary repair.
74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condtion of class.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 23 July 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Class 1 WTD between bow thruster & EOS is missing a closing assist bar on the bow thruster side of the WTD, which is causing the bar mounting socket to gouge into the WTD on the bow thruster side.
74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition of class.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 23 July 2024
Resolved
When a distribution system, whether primary or secondary for power, heating or lightening, with no connection to earth is used, a device capable of giving a visual indication of abnormally low insulation values shall be provided. Ground indication lights on emergency switch board could not be tested to indicate possible ground.
74SOLAS(04)II-1/45.4.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition of class.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 23 July 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. EDG bus tie breaker on EDG switchboard will not switch back as designed when switching from emergency power to ships power.
74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condtion of class.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 23 July 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. EDG switchboard lower breaker securing door handle is broken.
74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition of class
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 23 July 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Port radar was not fully operational.
74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition of class.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 23 July 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Overhead A/C Unit in Galley was leaking excessive amounts of water being captured in multiple pans on deck leading to unsafe condition.
74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition of class.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 23 July 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Electrical circuit breaker panel P101 had openings missing blanks.
74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condtion of class.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 July 2024
Resolved
A masthead light, side lights and a stern light installed on board ship not less than 50 m in length should be fitted with duplicate lamps. Stern light only had one circuit available because of faulty plug.
COLREGS 1972
MSC.253(83)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition of class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2024
Resolved
The main steering gear must be operable from the pilothouse by mechanical, hydraulic, electrical, or other means acceptable to the Commanding Officer, Marine Safety Center. This gear and its components must give full follow-up control of the rudder. Supplementary steering-gear control not giving full followup may also be provided from the pilothouse. Received a report that the vessel discharged approximately 1 liter of hydraulic fluid into the Delaware River due to faulty starboard z drive due to faulty air pressure regulator.
Vessel is required to submit tech report, cause analysis report to ABS, and conduct testing in the presence of ABS surveyor to their satisfaction.
Vsl is restricted prior to movement until the deficiency is resolved, but can test away from the pier in the presence of ABS.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 May 2024
Resolution: Received satisfactory ABS report
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2024
Resolved
While attempting to get underway to allow room for a barge to be place in between the pier and the vsl. The vsl experienced a loss/ malfunction of its stbd azipod/thruster.
Vsl is require to submits tech report, cause analysis report to ABS and conduct testing in the presence of ABS surveyor to their satisfaction.
74 SOLAS (20) II-1/26.1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 May 2024
Resolution: Received satisfactory ABS report.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 1 May 2023
Resolved
Details of fuel oil for combustion purposes delivered to and used on board shall be recorded by means of a bunker delivery note that shall contain at least the information specified in appendix V to this Annex. The vessel did not have on board bunker delivery notes complying with appendix V of Annex VI of MARPOL for their most recent bunkers delivered in April 2023.
Cite: MARPOL Annex VI Reg. 18.5
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 23 May 2023
Resolution: Vessel rep provided ABS Report of Finding with rectified deficiency; new delivery of fuel oil bunkers delivered to vessel with required bunker notes provided.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Other (MARPOL Annex VI)
Issued 1 May 2023
Resolved
The bunker delivery note shall be accompanied by a representative sample of the fuel oil delivered taking into account the guidelines developed by the Organization. The sample is to be sealed and signed by the supplier’s representative and the master or officer in charge of the bunker operation on completion of bunkering operations and retained under the ship’s control until the fuel oil is substantially consumed, but in any case for a period of not less than 12 months from the time of delivery. There were no fuel samples on board from the vessel’s recent bunkering in April 2023.
Cite: MARPOL Annex VI Reg. 18.8.1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 23 May 2023
Resolution: Vessel rep provided ABS Report of Finding with rectified deficiency; new delivery of fuel oil bunkers delivered to vessel with required bunker notes provided.
04 - Emergency Systems › N/A - No Subsystem › Enclosed space entry and rescue drills
Issued 1 May 2023
Resolved
Each enclosed space entry and rescue drill shall include: checking and use of instruments for measuring the atmosphere in enclosed spaces. The vessel did not have means on board to test enclosed spaces for rescue purposes in accordance with their on board checklist for enclosed space rescue.
Cite: 74 SOLAS (2020 Con.) III/Reg 19.3.6.2.3
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 23 May 2023
Resolution: Vessel rep provided ABS Report with Findings Rectified; portable gas analyzer onboard and calibrated.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 1 May 2023
Resolved
Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing. The fire boundaries in the engine room including the watertight door leading to the tank farm and the fire door leading to the stairwell were found not to be self-closing. Both closure devices were not closing the doors completely.
Cite: 74 SOLAS (09 Con.) II-2/Reg. 9.4.2.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 15 May 2023
Resolved 2 May 2023
Resolution: Vessel demonstrated fire doors closing completely.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 May 2023
Resolved
A fixed storage tank having sufficiency capacity to recharge at least one power actuating system including the reservoir, where the main steering gear is required to be power operated. The storage tank shall be permanently connected by piping in such a manner that the hydraulic systems can be readily recharged from a position within the steering gear compartment and shall be provided with a contents gauge. The fixed storage tank in the steering gear room was found empty and incapable of being readily recharged form a position within the steering gear compartment.
Cite: 74 SOLAS (04 Con.) II/1 Reg. 29.12.3
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 23 May 2023
Resolution: Vessel rep provided ABS Report with findings rectified; hydraulic fluid tank filled with sufficient amount of fluid.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 May 2023
Resolved
The function of fixed fire detection and fire alarm systems shall be periodically tested to the satisfaction of the administration by means of equipment producing hot air at the appropriate temperature. The vessel’s crew did not have means to test the heat detectors in accordance with manufactures instructions. Testing was conducted by means of rubbing rope looped around the heat detector until the system alarmed.
Cite: 74 SOLAS (09 Con.) II-2/Reg 7.3.2
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 23 May 2023
Resolution: Vessel rep provided ABS Report of Finding with rectified deficiency
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 May 2023
Resolved
After any survey of the ship under article 14 has been completed, no change shall be made tin the structure, equipment, arrangements, material or scantlings covered by the survey, without the sanction of the Administration. The watertight hatches serving as the emergency escape from port and starboard side of the steering gear compartments were no longer water or weathertight. Additionally, the watertight door leading from the engine room to the tank farm did not completely close to remain watertight.
Cite: ICLL Annex A / Article 16
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 15 May 2023
Resolved 2 May 2023
Resolution: Vessel demonstrated escape hatches watertight and watertight door to be functional and close completely.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 May 2016
Resolved
Sternlight did not have required redundant lantern. required vessel rep to provide one.
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 26 May 2016
Resolution: recieved reciept for new sternlight
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 17 May 2016
Resolved
operating instructions were not posted in the CO2 room. required vessel rep to post operating instructions.
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 26 May 2016
Resolution: Recieved picture of operating instructions in CO2 room.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 17 May 2016
Resolved
shutoff remote valve was not labeled.
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 26 May 2016
Resolution: recieved picture of satisfactory labeling
Construction/Loadline › Structures › Door
Issued 17 May 2016
Resolved
SFP classed hinged door had a long bolt in place of a hinge pin. requried them to repair IAW manufacturer's specifications.
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 26 May 2016
Resolution: Vessel rep confirmed repair of door via email.