MAURY USCG vessel records Sign in
← All vessels

KRAKEN

KRAKEN is a 2004 industrial vessel. The Coast Guard has recorded 42 inspections since 2004, most recently in January 2025, along with 45 deficiencies, 1 operational control and 4 casualty investigations between 2007 and 2024.

Records from 2004 to 2025. Most recent: inspection, 14 January 2025.

Built
2004
Last inspected
14 January 2025
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9285275 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
722928
Flag
UNITED STATES
366907000, 366980740 (licence lapsed)
Maury page id
psix-722928

Inspections, by type

…with no type recorded6
Years with a record 15 calendar years (2004–2025)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)234.4 ft × 54.1 ft × 19.0 ft
Registered tonnagegross 2,045 / net 797
ITC dimensions (L × B × D)234.4 ft × 54.1 ft × 19.0 ft
ITC tonnagegross 2,045 / net 797
BuilderBENDER SHIPBUILDING & REPAIR CO INC · MOBILE, AL, UNITED STATES · built 2004
Hull materialSteel
PropulsionDiesel Electric
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 5 November 2004
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2045 - Convention (Subpart B), Gross Ton
2310 - Dead Weight, Net Ton
797 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WAOZMMSI 366907000 · cancelled · compulsorily equipped · granted 10 January 2023, cancelled 6 March 2025
WDD3651MMSI 366980740 · cancelled · compulsorily equipped · granted 27 May 2016, cancelled 3 January 2023
WDB9678MMSI 366980740 · cancelled · compulsorily equipped · granted 29 September 2004, cancelled 8 August 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAPE STARR Freight Ship · MISLE 1770691 · 26 October 2024 · activity 8026695

Inspection history · 42

14 January 2025 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8063302
30 December 2024 Administrative Inspection
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 8053012
28 October 2024 MTSA/ISPS Verification · Deficiency Check · In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8025615
26 October 2024 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8026695
23 July 2024 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7964188
16 May 2024 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7915763
6 May 2024 Deficiency Check · Permit to Proceed · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7907657
29 April 2024 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7903465
3 February 2024 ACP Additional Oversight – Risk Assessment · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7860099
26 October 2023 Administrative Inspection · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7814965
13 September 2023 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7791338
11 September 2023 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7789288
16 May 2023 In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7677283
23 March 2023 Re-Inspection · Deficiency Check · Administrative Inspection · ACP COI Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7663543
2 December 2019 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6879114
26 March 2019 Annual Inspection · ACP Annual Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6649695
19 March 2019 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6645525
22 March 2018 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6376946
20 March 2018 Administrative Inspection · Periodic Inspection · ACP Periodic Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6374988
29 June 2017 ACP Annual Oversight · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6190630
16 November 2016 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6042339
17 May 2016 Annual Inspection · ACP Annual Oversight · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5879820
26 January 2012 ACP Annual Oversight
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4231312
31 January 2011 MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3936653
14 January 2009 ACP Annual Oversight
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3391393
10 January 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3130595
21 September 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3063462
19 September 2007 ACP Annual Oversight
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3132087
28 February 2007 ACP Annual Oversight
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2879810
6 September 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2770511
7 March 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2597931
17 February 2006 ACP Annual Oversight
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2587086
23 January 2006 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2571522
23 January 2006 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2571857
14 July 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2426328
7 June 2005 MARPOL Annex II Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2382928
18 April 2005 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2336489
7 February 2005 Administrative Inspection · MTSA/ISPS Verification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2287936
17 December 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2261110
7 December 2004 Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2254949
27 October 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2229488
4 October 2004 MTSA/ISPS Verification · Initial Certification · ACP COI Oversight · Construction Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2212758

Deficiency record · 45

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 October 2024 Resolved
Efficient guard rails or bulwarks shall be fitted to all exposed parts of the freeboard and superstructure decks. The height of the bulwarks or guard rails shall be at least 1m (39 ½”) from the deck. Bulwarks on stern of vessel are missing.
Action required: 60 - Rectify deficiencies prior to movement
Due 29 October 2024
Resolved 31 October 2024
Resolution: Accepted as Condition of Class.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 28 October 2024 Resolved
All hatchways in position 1 and position 2 shall be fitted with hatch covers of steel ... [and the] covers shall be weathertight. The means for securing and maintaining weathertightness shall be to the satisfaction of the Administration. The arrangements shall ensure that the tightness can be maintained in any sea conditions. Emergency escape hatch from starboard Z-drive room is seized and cannot be closed.
Action required: 60 - Rectify deficiencies prior to movement
Due 29 October 2024
Resolved 31 October 2024
Resolution: Accepted as condition of class.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 28 October 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects is safe to proceed to sea without danger to the ship or persons on board. Vessel has an approximately a 6 inch hole burned through port side aft main deck in way of Z-Drive Room.
Action required: 60 - Rectify deficiencies prior to movement
Due 29 October 2024
Resolved 31 October 2024
Resolution: Accepted as condition of class.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 23 July 2024 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including of openings and penetrations in these divisions. Engine Room ventilation damper would not close. 74SOLAS(20)II-2/14.2.1
Action required: 60 - Rectify deficiencies prior to movement
Due 23 July 2024
Resolved 25 July 2024
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 July 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Port day tank remote fuel valve inop. 74SOLAS(20)I/11(a)
Action required: 60 - Rectify deficiencies prior to movement
Due 23 July 2024
Resolved 25 July 2024
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 23 July 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Public Address System did not operate in a all accommodation, engineering spaces and PAMs. 74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 25 July 2024
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 23 July 2024 Resolved
An onboard means of recharging breathing apparatus cylinders used during drills shall be provided or suitable number of spare cylinders shall be carried on board to replace those used. No spares or recharging capabilities onboard. 74SOLAS(20)II-2/15.2.2.6
Action required: 60 - Rectify deficiencies prior to movement
Due 23 July 2024
Resolved 25 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 July 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Port Z drive has reoccurring steering failure alarms due to brake chopper on the #1 steering motor. 74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition of class.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 July 2024 Resolved
Fire protection systems shall be kept in good working order so as to ensure their performance if a fire occurs: structural fire protection. Stair tower door leading to EOS missing latch and handle. 74SOLAS(20)II-2/14.2.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition class.
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 23 July 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. STBD Potable water piping has patch with belzona and a hose clamp. 74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition of class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 July 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. #2 Diesel Generator (Harbor Generator) is missing speed sensor and will not stay running. 74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as Condition of Class.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 July 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. STBD Vent Duct outboard of no.3 diesel generator is being held in place with rope. 74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condtion of class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 July 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Vessel could not locate automation testing procedures or provide proof of completion. 74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition of class.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 July 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Red Rotating Alarm lights in Machinery Spaces & Tank Farm were not operational. 74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition of class
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 23 July 2024 Resolved
The activation of any detector or manual operated call point shall initiate visible and audible fire signal at control panel. If signals have not received attention with in 2 mins, an audible alarm shall automatically be sounded throughout the crew accommodations, service stations, control stations and machinery spaces of cat A. Fire Alarm purposely was left unacknowledged to test and alarm did not sound through out spaces after 3 minutes. 74SOLAS(09)II-2-7.2.2 FSS Code(07) 2.5.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition of class.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 23 July 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Public Address speaker hanging from wire in Z-Drive Room & Bow thruster space. 74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition of class.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 23 July 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Red rotating alarm beacon on port side is hanging from wire in Z-Drive room not properly mounted. 74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition of class.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 23 July 2024 Resolved
A means of communication should be provided between then Navigation Bridge and Steering gear compartment. Sound Powered Phone cable was not long enough could not reach the viewable vantage point for either Z drives controls. 74SOLAS(04) II-1 29.10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as conditon of class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 July 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Both steering pump motor housings not properly secured/vibrating. 74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condtion of class.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 23 July 2024 Resolved
Power-operated steering gear shall be provided with the following: A low level alarm for each hydraulic fluid reservoir to give the earliest indication of hydraulic fluid leakage. Vessel could not test or demonstrate operation of alarm. SOLAS (04) II-1/29.12.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condtion of class.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 July 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Emergency Fire Pump sea chest vent pipe had temporary repair. 74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condtion of class.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 23 July 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Class 1 WTD between bow thruster & EOS is missing a closing assist bar on the bow thruster side of the WTD, which is causing the bar mounting socket to gouge into the WTD on the bow thruster side. 74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition of class.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 23 July 2024 Resolved
When a distribution system, whether primary or secondary for power, heating or lightening, with no connection to earth is used, a device capable of giving a visual indication of abnormally low insulation values shall be provided. Ground indication lights on emergency switch board could not be tested to indicate possible ground. 74SOLAS(04)II-1/45.4.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition of class.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 23 July 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. EDG bus tie breaker on EDG switchboard will not switch back as designed when switching from emergency power to ships power. 74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condtion of class.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 23 July 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. EDG switchboard lower breaker securing door handle is broken. 74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition of class
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 23 July 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Port radar was not fully operational. 74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition of class.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 23 July 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Overhead A/C Unit in Galley was leaking excessive amounts of water being captured in multiple pans on deck leading to unsafe condition. 74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition of class.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 23 July 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Electrical circuit breaker panel P101 had openings missing blanks. 74SOLAS(20)I/11(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condtion of class.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 July 2024 Resolved
A masthead light, side lights and a stern light installed on board ship not less than 50 m in length should be fitted with duplicate lamps. Stern light only had one circuit available because of faulty plug. COLREGS 1972 MSC.253(83)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2024
Resolved 1 August 2024
Resolution: Accepted as condition of class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2024 Resolved
The main steering gear must be operable from the pilothouse by mechanical, hydraulic, electrical, or other means acceptable to the Commanding Officer, Marine Safety Center. This gear and its components must give full follow-up control of the rudder. Supplementary steering-gear control not giving full followup may also be provided from the pilothouse. Received a report that the vessel discharged approximately 1 liter of hydraulic fluid into the Delaware River due to faulty starboard z drive due to faulty air pressure regulator. Vessel is required to submit tech report, cause analysis report to ABS, and conduct testing in the presence of ABS surveyor to their satisfaction. Vsl is restricted prior to movement until the deficiency is resolved, but can test away from the pier in the presence of ABS.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 May 2024
Resolution: Received satisfactory ABS report
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2024 Resolved
While attempting to get underway to allow room for a barge to be place in between the pier and the vsl. The vsl experienced a loss/ malfunction of its stbd azipod/thruster. Vsl is require to submits tech report, cause analysis report to ABS and conduct testing in the presence of ABS surveyor to their satisfaction. 74 SOLAS (20) II-1/26.1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 May 2024
Resolution: Received satisfactory ABS report.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 1 May 2023 Resolved
Details of fuel oil for combustion purposes delivered to and used on board shall be recorded by means of a bunker delivery note that shall contain at least the information specified in appendix V to this Annex. The vessel did not have on board bunker delivery notes complying with appendix V of Annex VI of MARPOL for their most recent bunkers delivered in April 2023. Cite: MARPOL Annex VI Reg. 18.5
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 23 May 2023
Resolution: Vessel rep provided ABS Report of Finding with rectified deficiency; new delivery of fuel oil bunkers delivered to vessel with required bunker notes provided.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Other (MARPOL Annex VI)
Issued 1 May 2023 Resolved
The bunker delivery note shall be accompanied by a representative sample of the fuel oil delivered taking into account the guidelines developed by the Organization. The sample is to be sealed and signed by the supplier’s representative and the master or officer in charge of the bunker operation on completion of bunkering operations and retained under the ship’s control until the fuel oil is substantially consumed, but in any case for a period of not less than 12 months from the time of delivery. There were no fuel samples on board from the vessel’s recent bunkering in April 2023. Cite: MARPOL Annex VI Reg. 18.8.1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 23 May 2023
Resolution: Vessel rep provided ABS Report of Finding with rectified deficiency; new delivery of fuel oil bunkers delivered to vessel with required bunker notes provided.
04 - Emergency Systems › N/A - No Subsystem › Enclosed space entry and rescue drills
Issued 1 May 2023 Resolved
Each enclosed space entry and rescue drill shall include: checking and use of instruments for measuring the atmosphere in enclosed spaces. The vessel did not have means on board to test enclosed spaces for rescue purposes in accordance with their on board checklist for enclosed space rescue. Cite: 74 SOLAS (2020 Con.) III/Reg 19.3.6.2.3
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 23 May 2023
Resolution: Vessel rep provided ABS Report with Findings Rectified; portable gas analyzer onboard and calibrated.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 1 May 2023 Resolved
Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing. The fire boundaries in the engine room including the watertight door leading to the tank farm and the fire door leading to the stairwell were found not to be self-closing. Both closure devices were not closing the doors completely. Cite: 74 SOLAS (09 Con.) II-2/Reg. 9.4.2.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 15 May 2023
Resolved 2 May 2023
Resolution: Vessel demonstrated fire doors closing completely.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 May 2023 Resolved
A fixed storage tank having sufficiency capacity to recharge at least one power actuating system including the reservoir, where the main steering gear is required to be power operated. The storage tank shall be permanently connected by piping in such a manner that the hydraulic systems can be readily recharged from a position within the steering gear compartment and shall be provided with a contents gauge. The fixed storage tank in the steering gear room was found empty and incapable of being readily recharged form a position within the steering gear compartment. Cite: 74 SOLAS (04 Con.) II/1 Reg. 29.12.3
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 23 May 2023
Resolution: Vessel rep provided ABS Report with findings rectified; hydraulic fluid tank filled with sufficient amount of fluid.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 May 2023 Resolved
The function of fixed fire detection and fire alarm systems shall be periodically tested to the satisfaction of the administration by means of equipment producing hot air at the appropriate temperature. The vessel’s crew did not have means to test the heat detectors in accordance with manufactures instructions. Testing was conducted by means of rubbing rope looped around the heat detector until the system alarmed. Cite: 74 SOLAS (09 Con.) II-2/Reg 7.3.2
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 23 May 2023
Resolution: Vessel rep provided ABS Report of Finding with rectified deficiency
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 1 May 2023 Resolved
After any survey of the ship under article 14 has been completed, no change shall be made tin the structure, equipment, arrangements, material or scantlings covered by the survey, without the sanction of the Administration. The watertight hatches serving as the emergency escape from port and starboard side of the steering gear compartments were no longer water or weathertight. Additionally, the watertight door leading from the engine room to the tank farm did not completely close to remain watertight. Cite: ICLL Annex A / Article 16
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 15 May 2023
Resolved 2 May 2023
Resolution: Vessel demonstrated escape hatches watertight and watertight door to be functional and close completely.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 May 2016 Resolved
Sternlight did not have required redundant lantern. required vessel rep to provide one.
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 26 May 2016
Resolution: recieved reciept for new sternlight
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 17 May 2016 Resolved
operating instructions were not posted in the CO2 room. required vessel rep to post operating instructions.
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 26 May 2016
Resolution: Recieved picture of operating instructions in CO2 room.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 17 May 2016 Resolved
shutoff remote valve was not labeled.
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 26 May 2016
Resolution: recieved picture of satisfactory labeling
Construction/Loadline › Structures › Door
Issued 17 May 2016 Resolved
SFP classed hinged door had a long bolt in place of a hinge pin. requried them to repair IAW manufacturer's specifications.
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 26 May 2016
Resolution: Vessel rep confirmed repair of door via email.
Lifesaving › Rescue Boat › Markings
Issued 28 February 2007 Resolved
STENCIL CAPACITY OF PERSONS ON RESCUE BOAT.
Action required: 705 - Other - as specified
Due 28 March 2007
Resolved 28 February 2007
Resolution: COMPLETED
Lifesaving › Rescue Boat Equipment › Instructions (engine start/operation)
Issued 28 February 2007 Resolved
DISPLAY LAUNCHING INSTRUCTIONS.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 March 2007
Resolved 28 February 2007
Resolution: COMPLETED
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 28 February 2007 Resolved
PROVIDE AND INSTALL GROUNDING MAT AT TWO MAIN SWITCHBOARD LOCATIONS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2007
Resolved 28 February 2007
Resolution: COMPLETED

Casualty record · 4

21 September 2007Routine · role: Involved in a Marine Casualty · at BRMORM HWY 90 (OLD), AMELIA LA · activity 3063462
10 January 2008Routine · role: Involved in a Marine Casualty · activity 3130595
13 September 2023Routine · role: Acknowledged Pollution Source · activity 7791338
26 October 2024Routine · role: Involved in a Marine Casualty · 1 dead · activity 8026695
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

IBERVILLE (2007–2008), ATLANTIC OCEANIC (2023–2024). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.