Records from 2004 to 2025. Most recent: operational control imposed, 14 May 2025.
Inspection history · 19
14 May 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8135781
4 November 2022
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7589431
7 October 2019
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6830816
26 July 2019
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6743022
20 August 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6245261
13 October 2015
COE-Offshore · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5741133
9 October 2015
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5739533
4 August 2011
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4095116
28 September 2010
NPV Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3858862
27 September 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3859171
10 December 2009
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3648293
6 July 2009
Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3526127
24 November 2007
PII Safety Exam · Deficiency Check · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3102281
6 July 2007
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2985792
19 September 2006
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2782256
15 September 2006
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2778473
7 December 2005
ISPS II Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2544324
10 October 2004
ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2216119
8 October 2004
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2220922
Communications › Radio Communications › EPIRB
Issued 4 August 2011
Resolved
1671 The HAMMAR H20 E may only be used on an EPIRB assembly. Currently the HAMMAR H20 R is installed on the EPIRB assembly and it can only be used on life rafts. Using the HAMMAR H20 R on a EPIRB assembly will not allow the EPIRB to be released. 74 SOLAS (09 con) IV/10.2.3 17c
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2011
Resolution: Received a receipt and photograph of a proper hydrostatic release being installed. (see attached documents)
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 6 July 2009
Resolved
0715: The heat detectors are being tested by use of a hand lighter. Suitable means for testing could not be provided as per FSS Code 9.2.5.2.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 July 2009
Resolved 10 December 2009
Resolution: received class report stating correct testing procedures and equipment are onboard and detectors are operating as designed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 July 2009
Resolved
0830: Packing around conduit for electrical (captain identified them, however, as hydraulic lines; however, the copper securing them were painted grey making them appear to be electrical) wires on starboard side of cargo holds are deteriorating, thus allowing water ingress which could lead to electrical shock/ failure. Packing needs to be addressed by class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 July 2009
Resolved 10 December 2009
Resolution: Received Class report identified the lines as hydraulic lines and found to be satisfactory, class also renewed all the packing around the lines as necessary.
Operations/Management › Drills/Instruction › Fire
Issued 6 July 2009
Resolved
2020: Crew failed first fire drill for entering improper/incorrect space and for not bringing proper fire gear. Crew was given time to correct mistakes and conducted a second fire drill.
Due 7 July 2009
Resolved 7 July 2009
Resolution: Crew passed second fire drill.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 24 November 2007
Resolved
BWM Plan is not ship specific. Plan indicates on 12 tanks utilized for ballast. Reporting form indicates 13 tanks used for ballasting. C/O stated that hold #3 is also used for ballast. Update plan to satisfaction of class and USCG.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 December 2007
Resolution: Reviewed NK Class Survey Record No. 07ST0386. Deficiency resolved by Class.
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 24 November 2007
Resolved
International Sewage Pollution Prevention Certificate (ISPP) identifies no holding tanks on board for the storage of sewage. Captain stated that sewage is stored in the Aft Peak Tank when ship is going to or in port. Class must verify tank and piping is in compliance with certificate. MARPOL Annex IV Reg 4.7
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 December 2007
Resolution: Reviewed NK Class Survey Record No. 07ST0386. Deficiency resolved by Class.
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 24 November 2007
Resolved
Pilot card used to notify pilot of vessel specifics for safe navigation to Port of Stockton did not indicate the air draft. Determine air draft and fax completed pilot card to [phone withheld] prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 November 2007
Resolution: Master provided pilot card for transit from Stockton berth.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 24 November 2007
Resolved
SOLAS Training manuals are not ship specific. Lifesaving and firefighting equipment is not detailed to the vessel specific equipment. Add training information for equipment on board. Rectify to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 December 2007
Resolution: Reviewed NK Class Survey Record No. 07ST0386. Deficiency resolved by Class.