MAURY USCG vessel records Sign in
← All vessels

ETC ISIS

ETC ISIS is a 2000 tank ship. The Coast Guard has recorded 34 inspections since 2004, most recently in April 2016, along with 6 deficiencies and 14 operational controls.

Records from 2004 to 2016. Most recent: operational control imposed, 28 April 2016.

Built
2000
Last inspected
26 April 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9229427 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
728580
Flag
LIBERIA
—
Maury page id
psix-728580

Inspections, by type

…with no type recorded21
Years with a record 9 calendar years (2004–2016)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it31693 - Convention (Subpart B), Net Ton
123877 - Displacement, Ton
107181 - Dead Weight, Ton
57920 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

HELEN MORAN Towing Vessel · MISLE 86920 · 12 November 2004 · activity 2242940MARY MORAN Towing Vessel · MISLE 152869 · 12 November 2004 · activity 2242940WARSAW Freight Ship · MISLE 225038 · 12 November 2004 · activity 2242940

Inspection history · 34

26 April 2016 Ballast Water Examination · ISPS III Exam · NPV Safety Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5863062
1 April 2016 PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5845029
29 September 2015 Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5720291
19 September 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4155104
9 July 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3522580
22 April 2009 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3458187
8 April 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3448831
2 April 2009 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3445108
19 March 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3433916
16 March 2009 COE-Administrative
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3434543
13 February 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3415133
11 November 2008 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3358875
5 June 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3228246
4 June 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3227668
15 November 2007 ISPS II Exam · STCW 95 Exam · COC-TVE Annual · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3097734
16 January 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2854076
14 August 2006 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2747687
5 May 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2643825
5 May 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2646734
1 May 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2638325
23 March 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2608375
20 March 2006 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2606016
1 March 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2594128
20 November 2005 ISPS II Exam · COC-TVE Annual
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2537853
24 October 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2521532
4 August 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2452215
22 June 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2399376
8 June 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2386843
31 January 2005 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2283727
20 January 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2281274
5 January 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2269735
12 November 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2242940
11 November 2004 ISPS II Exam · COC-TVE Renew
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2236932
8 November 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2236800

Deficiency record · 6

Documentation › Certificates/Documents › IOPP Certificate
Issued 28 April 2016 Resolved
The vessel's primary bilge tank with a capacity 2.2m3 holds oily bilge water and is not listed on the IOPP Form B, making the certificate invalid.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2016
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Pump
Issued 27 April 2016 Resolved
During examination, it was discovered that oily bilge water was being discharged overboard through unapproved piping arrangements. Missing portable pneumatic chemical pump was found by a member of the Port State Control team completely submerged in the primary bilge tank. It was tied off to a pipe located inside the tank above the oily water level. Vessel Captain refused to sign.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2016
Documentation › Logs/Records › Oil Record Book
Issued 26 April 2016 Resolved
Operation of the oily water separator on 10APR2016 was not recorded in the Oil Record Book Part I.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 May 2016
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 1 April 2016 Resolved
0599-Other (workspaces) - Shall maintain the condition of the vessel to maintain safety of the vessel and crew while at sea. A room as been converted to the electrician's workshop with a shalf and desk being installed. Also storage of batteries and other flammable materials were found.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 April 2016
Resolved 26 April 2016
Resolution: Received class report attesting to proper use of the space.
Construction/Loadline › Structures › Air Pipe
Issued 11 November 2004 Resolved
No. 6 Center Ballast Tank vent fractured at deck, due to collision. Permanent repairs to be made during vessel's scheduled dry dock, (28 March 2006).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 20 March 2006
Resolution: Received classification report clearing deficiency.
Construction/Loadline › Hull › Sheerstrake
Issued 11 November 2004 Resolved
Approximately 20' of sheer strake at port-quarter, attached stanchons, handrails, and associated materials/equipment damaged by collison. Repairs to be made during vessel's scheduled dry dock, (28 March 2006).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 20 March 2006
Resolution: Received classification report clearing deficiency.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.