Records from 2004 to 2016. Most recent: operational control imposed, 28 April 2016.
Inspection history · 34
26 April 2016
Ballast Water Examination · ISPS III Exam · NPV Safety Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5863062
1 April 2016
PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5845029
29 September 2015
Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5720291
19 September 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4155104
9 July 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3522580
22 April 2009
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3458187
8 April 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3448831
2 April 2009
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3445108
19 March 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3433916
16 March 2009
COE-Administrative
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3434543
13 February 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3415133
11 November 2008
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3358875
5 June 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3228246
4 June 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3227668
15 November 2007
ISPS II Exam · STCW 95 Exam · COC-TVE Annual · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3097734
16 January 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2854076
14 August 2006
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2747687
5 May 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2643825
5 May 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2646734
1 May 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2638325
23 March 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2608375
20 March 2006
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2606016
1 March 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2594128
20 November 2005
ISPS II Exam · COC-TVE Annual
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2537853
24 October 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2521532
4 August 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2452215
22 June 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2399376
8 June 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2386843
31 January 2005
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2283727
20 January 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2281274
5 January 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2269735
12 November 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2242940
11 November 2004
ISPS II Exam · COC-TVE Renew
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2236932
8 November 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2236800
Documentation › Certificates/Documents › IOPP Certificate
Issued 28 April 2016
Resolved
The vessel's primary bilge tank with a capacity 2.2m3 holds oily bilge water and is not listed on the IOPP Form B, making the certificate invalid.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2016
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Pump
Issued 27 April 2016
Resolved
During examination, it was discovered that oily bilge water was being discharged overboard through unapproved piping arrangements. Missing portable pneumatic chemical pump was found by a member of the Port State Control team completely submerged in the primary bilge tank. It was tied off to a pipe located inside the tank above the oily water level. Vessel Captain refused to sign.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2016
Documentation › Logs/Records › Oil Record Book
Issued 26 April 2016
Resolved
Operation of the oily water separator on 10APR2016 was not recorded in the Oil Record Book Part I.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 May 2016
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 1 April 2016
Resolved
0599-Other (workspaces) - Shall maintain the condition of the vessel to maintain safety of the vessel and crew while at sea. A room as been converted to the electrician's workshop with a shalf and desk being installed. Also storage of batteries and other flammable materials were found.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 April 2016
Resolved 26 April 2016
Resolution: Received class report attesting to proper use of the space.
Construction/Loadline › Structures › Air Pipe
Issued 11 November 2004
Resolved
No. 6 Center Ballast Tank vent fractured at deck, due to collision. Permanent repairs to be made during vessel's scheduled dry dock, (28 March 2006).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 20 March 2006
Resolution: Received classification report clearing deficiency.
Construction/Loadline › Hull › Sheerstrake
Issued 11 November 2004
Resolved
Approximately 20' of sheer strake at port-quarter, attached stanchons, handrails, and associated materials/equipment damaged by collison. Repairs to be made during vessel's scheduled dry dock, (28 March 2006).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 March 2006
Resolved 20 March 2006
Resolution: Received classification report clearing deficiency.